Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Braun, Modelo BP3510

Fabricante : Braun
Arquivo Tamanho: 3.63 mb
Arquivo Nome : D6083_1_AMEE.pdf
Língua de Ensino: entrro
Ir para baixar



Facilidade de uso


• Wait approximately 3 minutes before repeating a measurement. distance2 cm 2 cm memoclick! Measuring For a reliable blood pressure measurement, please follow the instructions below. To open the cuff, press the release button (F) underneath the cuff closure. 1. Place the monitor housing on the slim side of your bare forearm with the monitor facing up. The distance aid (H) helps you to keep the required 2 cm distance to your palm line. 2. To close the cuff, hold the appliance against your body. Then take hold of the cuff closure, pull out the cuff and insert the cuff closure in the monitor housing until it locks into place. The cuff will adjust automatically to length needed for your wrist. Once cuff is closed, do not move the appliance anymore. If you want to change the monitor position on your arm, open and close the cuff once again. 3. Press the red on/off button (B). 4. Put the hand with the appliance on the other upper arm as shown. Slowly move the hand upward along the upper arm. Watch the positioning system (A) and move your hand up or down according to the direction of the arrow shown. 5. The positioning system (A) shown on the left and a beep confirm that you have reached the right measuring position. The measurement will start automatically. When the measurement is complete, a beep will sound again, and the reading is displayed: Upper (systolic) value Lower (diastolic) value Pulse Please note: • In case of system errors or handling mistakes, the display will show an error code, instead of giving you inaccurate results (for details, please see section «What to do if…»). • 15 seconds after switching on the appliance, the measuring process will start automatically, even if the appropriate measuring position has not been reached. Turning off Press the on/off button to turn the product off. Otherwise the product will turn off automatically after 2 minutes. Memory mode Your blood pressure monitor can store the readings of 50 measurements. Storing is done automatically after each completed measurement. The memory is non-volatile. This means that you will not loose stored data when changing batteries. The memory cannot be cleared. Once the memory is full, the oldest values will be overwritten. Recalling stored readings To recall stored readings, first turn the product off, then press the memory button (D). A single push (m or n) will recall the latest reading. The lower display line successively shows memory index and pulse on the one hand and date and time of the respective measurement on the other hand. Repeatedly pressing the memory button (D) will call up one by one all stored readings: m (–) towards older readings n (+) towards younger readings Scrolling Keep one side of the memory button pressed for scrolling through the memory. Press the on/off button (B) to exit the memory mode. Select mode Setting date and time First turn off the appliance. Push the select button (C) for longer than 3 seconds to enter the select mode. Wait for a confirmation beep. The day position of the displayed date starts flashing. Using the memory button (D), you can adjust the date. Press the select button again to make the month position flash, adjust it using the memory button. Press the select button again and proceed the same way to adjust the time (hour/minute). After having changed date and time, press the on/off button (B) to confirm. The device will then turn off. Deactivating the positioning system Should you wish to deactivate the positioning system (e.g. because you want to measure while lying down), proceed as follows: Turn off the product. Push the select button (C) for longer than 3 seconds and wait for the confirmation beep. The display shows the date and time settings. Then repeatedly press the select button until the positioning system symbol ( ) will be displayed next to a flashing «ON». Press one side of the memory button to change the setting from «ON» (positioning system activated) to «OFF» (positioning system deactivated). To confirm the change of setting, press the on/off button (B). Please note: Unless you confirm a modified setting by pressing the on/off button, the appliance will turn off automatically after 2 minutes without adapting the modified setting. Storage and cleaning Clean the product with a soft, slightly damp cloth. Stains on the cuff can be carefully removed with damp cloth. Do not wash or dry clean the cuff. Do not store the product in a place exposed to direct sunlight or high humidity. Calibration This product has been calibrated at the time of manufacture. If used according to the use instructions, periodic re-calibration is not required. If at any time, you question the measuring accuracy, please contact a Braun Service Centre. Manufacturing date is given by the LOT number on the back of the product. The first number after LOT represents the last digit of the year of manufacture. The next three digits give the day of the year of manufacture. An example: LOT 4116 xx xx – this produc...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias