Log:
Assessments - 5, GPA: 4.4 ( )

Instruções de Operação Baracoda, Modelo BL2604

Fabricante : Baracoda
Arquivo Tamanho: 564.46 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The default settings will be restored whenever the "Reset" programming label is scanned and the laser scanner is in programming mode. 1.1 Default values of operating parameters Function Default Values Scanning Mode Selection Trigger mode Header and Trailer None Good Read Beeper Tone Selection 2.3KHz/50 msec (medium) Code Identifier Transmitting Disable 1.2 Predefined barcode identifiers Function Default Values Code 39 Barcode Identifier Code M ITF 2 of 5 Barcode Identifier Code I Chinese Post Code Identifier Code H UPC-E Barcode Identifier Code E UPC-A Barcode Identifier Code A EAN-13 Barcode Identifier Code F EAN-8 Barcode Identifier Code FF Coda bar Barcode Identifier Code N Code 128 Barcode Identifier Code K Code 93 Barcode Identifier Code L MSI Barcode Identifier Code P Industry 2 of 5 Identifier Code R IATA Identifier Code T 1.3 Default values of decoding parameters Function Code Default Value Reading codes Selection Code 39 Enable ITF 2 of 5 Enable Chinese Post Code Disable UPC/EAN/JAN Enable Codabar Enable MSI/PLESSY Disable Code 128 Enable Code 93 Enable ITAT Disable EAN-128 Disable Industry 2 of 5 Disable Italian Pharmacy Disable ISSN/ ISBN Disable Code 39 Codes Standard Start/stop characters Not transmitting Check digit Disabled Interleaved 2 of 5 Length 6-32 digits Check digit Disable Chinese Post Code Length 8~32digits Check digit Transmit UPC/EAN/JAN Format All Addendum Disable UPC-E=UPC-A Disabled UPC-A leading digit Transmit UPC-A check digit Transmit UPC-E leading digit Transmit UPC-E check digit Transmit Coda bar Type Standard Start/stop characters A, B, C, D Length 6~32 digits Code 128 FNC 2 append Disable MSI Length Variable Check digit Double check but not transmit Italian Pharmacy Transmit "A" Character Not transmitting Industry 2 of 5 Length 6~32 digits 2 Program procedure using barcode menus Zone de Texte: END Zone de Texte: Read « End of configuration » Label Zone de Texte: FINISH Zone de Texte: SET DATA EDITING Zone de Texte: SET SYMBOLOGIES Zone de Texte: SET GENERAL CONFIGURATION Zone de Texte: SET ALL DEFAULTS Zone de Texte: Read « Start of configuration » Label Zone de Texte: START Zone de Texte: NO Zone de Texte: YES 3 Set all defaults Start of Configuration Default Settings The reading of the "Default settings” label turns all the parameters back to default settings. When you intend to turn your scanner back to default parameter, please scans the "Start of configuration" label first, then scan "Default settings" label and finally scan the "End of configuration" label. End of Configuration 4 General configuration Start of Configuration 4.1 Scanning mode selection The scanner becomes inactive as soon as the data is transmitted. It must be triggered to become active again. In auto scan mode, the scanner is still active after the data is transmitted, but the successive transmission of the same bar code is not allowed when the trigger switch is pressed again. Trigger mode Auto scan mode 4.2 Good read beeper tone selection You can use this option to set frequency and / or duration of the buzzer after successful reading. Low Medium High Disable 4.3 Sound duration long(120 ms) Medium(50 ms) Short(20 ms) Very short(5 ms) End of Configuration 5 Symbologies Start of Configuration Reading code selection Code 39 Enable Code 39 Disable Codabar Enable Codabar Disable UPC/ EAN/ JAN Enable UPC/ EAN/ JAN Disable ITF 2 of 5 Enable ITF 2 of 5 Disable Chinese Post Code Enable Chinese Post Code Disable Code 128 Enable Code 128 Disable Code 93 Enable Code 93 Disable EAN- 128 Enable EAN-128 Disable MSI Enable MSI Disable IATA Enable IATA Disable INDUSTRY 25 Enable INDUSTRY 25 Disable Italian Pharmacy Enable Italian Pharmacy Disable End of Configuration Start of Configuration Code 9 parameters setting CHARACTER SET Standard Code 39 Full ASCII Code 39 START/STOP CHARACTER TRANSMISSION Yes No CHECK DIGIT Calculate and Transmit Calculate but not Transmit No CONCATENATION Enable Disable IInterleaved 2 of 5 parameters setting Examples: Felting length 4 to 8 digits LENTGTH Scan:. Start of configuration .. Min .. 0 .. 4 .. set max .. 0 .. 8 .. set .. End of configuration MAX Min Set CHECK DIGIT No Calculate and Transmit Calculate but not Transmit End of Configuration Start of Configuration Chinese post code parameters setting LENGTH MAX MIN Set Scan:. Start of configuration .. Min .. 0 .. 4 .. set max .. 0 .. 8 .. set .. End of configuration CHECK DIGIT NO Calculate and Transmit Calculate but not Transmit Codabar/Monarch parameters setting START/ STOP CHARACTER TRANSMISSION No A, B, C, D DC1~DC4 a/ t, b/ n, c/ *, d/ e CONCATENATION Enable Disable End of Configuration Start of Configuration UPC/EAN/JAN parameters setting FORMAT : All EAN-8 or EAN-13 UPC-A and EAN-13 UPC-A and UPC-E UPC-A UPC-E EAN-13 EAN-8 ADDENDUM : NO 5 Characters 2 Characters 2 or 5 Characters FORCE UPC-E TO UPC...

Este manual também é adequado para os modelos :
Equipamentos de Loja - BC2604 (564.46 kb)
Equipamentos de Loja - BLR2604 (564.46 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias