Log:
Assessments - 2, GPA: 3 ( )

Instruções de Operação Baracoda, Modelo BLR2604

Fabricante : Baracoda
Arquivo Tamanho: 564.46 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Start of configuration .. Min .. 0 .. 4 .. set max .. 0 .. 8 .. set .. End of configuration MAX Min Set CHECK DIGIT No Calculate and Transmit Calculate but not Transmit End of Configuration Start of Configuration Chinese post code parameters setting LENGTH MAX MIN Set Scan:. Start of configuration .. Min .. 0 .. 4 .. set max .. 0 .. 8 .. set .. End of configuration CHECK DIGIT NO Calculate and Transmit Calculate but not Transmit Codabar/Monarch parameters setting START/ STOP CHARACTER TRANSMISSION No A, B, C, D DC1~DC4 a/ t, b/ n, c/ *, d/ e CONCATENATION Enable Disable End of Configuration Start of Configuration UPC/EAN/JAN parameters setting FORMAT : All EAN-8 or EAN-13 UPC-A and EAN-13 UPC-A and UPC-E UPC-A UPC-E EAN-13 EAN-8 ADDENDUM : NO 5 Characters 2 Characters 2 or 5 Characters FORCE UPC-E TO UPC-A FORMAT Yes No FORCE UPC-A TO EAN-13 FORMAT Yes No TRANSMIT UPC-A LEADING CHARACTER Yes No TRANSMIT UPC-A CHECK DIGIT Yes No TRANSMIT UPC-E LEADING CHARACTER Yes No End of Configuration Start of Configuration UPC/EAN/JAN parameters settings (Cont’d) TRANSMIT UPC-E CHECK DIGIT Yes No TRANSMIT EAN-13 CHECK DIGIT Yes No TRANSMIT EAN-8 CHECK DIGIT Yes No Code 128 parameters setting FNC 2 CONCATENATION Enable Disable CHECK DIGIT No Calculate but not Transmit Calculate and Transmit UCC/EAN128 parameters setting The character FNC1 can be transmitted or not using these codes. FNC1 Character Transmitted FNC1 not Transmitted End of Configuration Start of Configuration Industry 25 parameters setting Examples: Felting length 4 to 8 characters Scan:. Start of configuration .. Min .. 0 .. 4 .. set max .. 0 .. 8 .. set .. End of configuration MAX Min Set Msi/Plessy setting Scan:. Start of configuration .. Min .. 0 .. 4 .. set max .. 0 .. 8 .. set .. End of configuration MAX Min Set Double Check digit Calculate but not Transmitted No Calculate but only first one Transmitted Calculated and both Transmitted End of Configuration Start of Configuration Italian pharmacy parameters setting TRANSMIT "A" CHARACTER Yes No Barcode length setting CODE 39 LENGTH SETTING MAX MIN CODE 93 LENGTH SETTING MAX MIN CODE 128 LENGTH SETTING MAX MIN CODABAR LENGTH SETTING MAX MIN SET End of Configuration Start of Configuration ISBN/ ISSN conversion The function convents the UPC/EAN codes appearing on books and magazine not ISBN/ISSN format. ACTIVE ISBN/ ISSN INACTIVE ISBN/ ISSN End of Configuration 6 Data editing Start of Configuration 6.1 Prefix and suffix This option allows you to append a prefix and/or a suffix to every message transmitted. There is no restriction in selecting prefix or suffix characters as far as the sum of the lengths of prefix and suffix is not greater than 10 digits. You must enable prefix/suffix with the BaracodaManager previously to configurate prefix and/or suffix (see 2604 protocol or BaracodaManager document) Prefix Suffix Set 1. Select either prefix or suffix you are going to program by scanning the corresponding label 2. Scan the character(s) you want from the enclosed ASCII table to set as prefix or suffix (be sure to enable full ASCII code 39 option before you start). 3. Read the “Set” label to set your choice into memory. 6.2 Barcode identifier code selection The scanners can transmit max.2-digit barcode identifier code for different types of barcodes. Use the labels to choose transmit or not transmit predefined barcode identifier code (ID’s are listed on section 1): Enable Disable 6.3 Barcode identifier code setting Each of the series type scanners can set max.2 digits as barcode identifier code according to different barcode. The procedure is as follows: 1. Scan “Start of configuration” label 2. Scan “Barcode identifier setting code” label. 3. Scan the new code mark from ASCII table (max. two digits). For example, if one “AB” want for code mark then scan “A” and “B”. 4. Scan “Set” label. 5. Scan “ End of configuration” label. UPC-E UPC-A EAN-13 EAN-8 Chinese post code ITF 2 OF 5 Coda bar Code 39 Code 128 Code 93 MSI INDUSTRY 25 IATA Set End of Configuration 7 Code 39 full ASCII barcode table Start of Configuration NUL ENQ (Up) SOH (Ins) ACK (Down) STX (Del) BEL (Left) ETX (Home) BS (Backspace) EOT (End) HT (TAB) LF (Enter)(num) DLE 5 (num) VT (Right) DC1 (F1) FF (PgUp) DC2 (F2) CR (Enter) DC3 (F3) SO (PgDn) DC4 (F4) SI shift(L) NAK (F5) SYN (F6) GS (ESC) ETB (F7) RS Ctl (L) CAN (F8) US Alt (L) EM (F9) SP SUB (F10) ! ESC (F11) " FS (F12) # $ + % , & - ' . ( / ) 0 * 1 2 : 3 ; 4 < 5 = 6 > 7 ? 8 @ 9 A B I C J D K E L F M G N H O P W Q X R Y S Z T [ U \ V ] ^ e _ f ` g a h b i c j d k l s m t n u o v p w q x r y z } { ~ | DEL End of Configuration ...

Este manual também é adequado para os modelos :
Equipamentos de Loja - BC2604 (564.46 kb)
Equipamentos de Loja - BL2604 (564.46 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias