Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação HP, Modelo HP SN6000 Stackable 8Gb 24-port Dual Power Fibre Channel Switch/S-Buy

Fabricante : HP
Arquivo Tamanho: 1.68 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


Document Outline

  • Contents
  • Preface
    • Document conventions
      • Text formatting conventions
      • Command syntax conventions
      • Notes, cautions, and warnings
    • Brocade resources
    • Contacting Brocade Technical Support
    • Document feedback
  • About This Document
    • Supported hardware and software
    • What is new in this document
  • FCIP Concepts and Features
    • FCIP concepts
      • VE_Ports and VEX_Ports
      • FCIP interfaces, circuits, and trunks
    • FCIP Trunking
      • Redundancy and fault tolerance
      • Tunnel restrictions for FCP and FICON acceleration
    • IP WAN network considerations
    • Adaptive Rate Limiting
      • 7840 Switch support
      • FSPF link cost calculation when ARL is used
      • Configuring ARL
      • ARL configuration limitations
    • Compression options
      • Brocade 7800 switch and FX8-24 blade
      • Brocade 7840 switch
    • FastWrite and Open Systems Tape Pipelining
      • FCIP FastWrite and OSTP configurations
    • Support for IPv6 addressing
      • IPv6 with embedded IPv4 addresses
    • Memory use limitations for large-device tunnel configurations
      • Control blocks created during FCP traffic flow
      • Control blocks created during FICON traffic flow
        • FDCBs example
      • Effect of configuration on tunnel control block memory
    • Firmware downloads
  • FCIP on Brocade Extension Switches and Blades
    • FCIP platforms and supported features
    • Brocade 7800 Extension Switch
      • License options
    • FX8-24 Extension Blade
      • Removing FX8-24 blades
      • License options
      • 10 GbE port considerations
      • Multigigabit circuits
      • Crossports
        • Configuring crossports
        • Configuring 10 GbE lossless failover with crossports
        • Configuring IP routes with crossports
        • Configuring VLAN tags with crossports
        • Displaying VLAN tag configuration using the portshow vlantag command
        • Using ping with crossports
        • Using traceroute with crossports
      • Bandwidth allocation and restrictions
        • Front-end and back-end bandwidth
        • Calculating back-end bandwidth
        • Calculating front-end bandwidth
        • Calculating crossport bandwidth
        • ARL limits
        • Failover circuits and groups
        • Bandwidth allocation example
    • Brocade 7840 Extension Switch
      • Brocade 7840 DP components and VE_Port distribution
      • 10 GbE and 40 GbE port considerations
        • Multigigabit circuits
      • Port grouping
      • 10VE and 20VE port modes
      • Extension Hot Code Load
        • Limitations and considerations
      • License options
    • Path Maximum Transmission Unit discovery
    • Tunnel and circuit requirements
      • General tunnel, circuit, and port requirements
      • Brocade 7800 extension switches
      • FX8-24 extension blades
      • Brocade 7840 extension switches
    • Circuit failover
      • Circuit Failover Grouping
        • Considerations and limitations
        • Examples of circuit failover in groups
        • Configuring circuit failover groups
        • Configuration examples
      • 10 GbE Lossless Link Loss (FX8-24 blade)
        • Configuring failover
          • Active-active configuration
          • Active-passive configuration
      • Failover in TI zones
      • Bandwidth calculation during failover
  • Configuring FCIP
    • Configuration preparation
    • Configuration steps
    • Setting VE_Ports to persistently disabled state
      • Disabling ports when FMS Mode is enabled
    • Configuring VEX_Ports
    • Configuring the media type for GbE ports 0 and 1 (Brocade 7800 switch)
    • Setting the GbE port operating mode (FX8-24 blade only)
    • Configuring port modes (Brocade 7840 switch)
    • Configuring port speed (Brocade 7840 switch)
    • Configuring an IPIF
    • Configuring an IP route
      • Commands for configuring IP routes
      • Commands for modifying IP routes
    • Validating IP connectivity
    • Creating an FCIP tunnel
      • Creating an FX8-24 and Brocade 7800 tunnel
      • Creating Brocade 7840 tunnels
      • Tunnel configuration options
      • Keep-alive timeout option
    • Creating additional FCIP circuits
    • Verifying the FCIP tunnel configuration
    • Configuring Extension HCL
      • Configuring backup tunnels
    • Enabling persistently disabled ports
      • Disabling ports with FMS Mode enabled
    • Creating an FCIP trunk (example)
    • Modifying an FCIP tunnel
    • Modifying an FCIP circuit
    • Deleting an IP interface
    • Deleting an IP route
    • Deleting an FCIP trunk
    • Deleting an FCIP circuit
    • Configuring PP-TCP-QoS priorities over an FCIP trunk
    • Modifying default priority values
    • Using FCIP with logical switches
      • Logical switch overview
        • Default logical switch
        • Creating logical switches
        • Port assignment
        • Logical switches and fabric IDs
        • Logical switch contexts
        • Connecting logical switches
        • For more information on virtual fabrics
      • FCIP considerations for logical switches
        • Ethernet port sharing
          • Limitations of Ethernet port sharing
          • Port sharing example
          • Configuring IP interfaces and IP routes
          • Configuring tunnels and circuits
        • Moving ports between logical switches
        • Displaying logical switch configurations
        • Brocade 7800 switch considerations and limitations
        • Brocade FX8-24 blade considerations and limitations
        • Enabling XISL for VE_Ports (FX8-24 blade)
        • Brocade 7840 switch considerations and limitations
    • Managing QoS, DSCP, and VLANs
      • DSCP Quality of Service
      • VLANs and Layer 2 Quality of Service
      • Managing DSCP and VLAN support on FCIP circuits
        • VLAN tagging examples
      • When both DSCP and L2CoS are used
      • Managing the VLAN tag table
    • Implementing IPsec over FCIP tunnels
      • Limitations using IPsec over FCIP tunnels
      • IPsec for the extension switches and blades
      • Enabling IPsec and IKE policies
    • Traffic Isolation Zoning
  • FCIP Management and Troubleshooting
    • In-band management
      • IP routing
      • Configuring IP addresses and routes
        • Management station on the same subnet example
        • Management station on a different subnet example
        • Redundant connections to the management stations example
      • VLAN tagging support
      • IP forwarding support
        • Using the ipfilter command
    • WAN performance analysis tools
      • The tperf option
      • Using ping to test a connection
      • Using traceroute
      • Using WAN Tool
        • WAN Tool commands
        • Configuring a WAN Tool session and displaying results
        • Resolving test session problems
    • Using the portshow command
      • Displaying IP interfaces
      • Displaying IP routes
      • Displaying FCIP tunnel information
      • Displaying IP addresses
      • Displaying performance statistics
      • Displaying QoS statistics
      • Displaying details
      • Displaying FCIP tunnel information
      • Displaying an FCIP tunnel with FCIP circuit information
      • Displaying FCIP tunnel performance
      • Displaying FCIP tunnel TCP statistics
      • Displaying FCIP circuits
      • Displaying a single circuit
      • Displaying TCP statistics for circuits
      • Displaying FCIP circuit performance
      • Displaying QoS prioritization for a circuit
      • Displaying FCIP tunnel information (FX8-24 blade)
    • FCIP tunnel issues
      • FCIP tunnel does not come online
      • FCIP tunnel goes online and offline
    • FCIP links
      • Gathering additional information
    • Using FTRACE
      • FTRACE configuration
        • Brocade 7800 switch and FX8-24 blade
        • Brocade 7840 switch
      • Changing configuration settings
        • Brocade 7840 switch example
        • Brocade 7800 switch example
      • Displaying FTRACE status on an FCIP DP complex
        • Brocade 7840 switch example
        • Brocade 7800 switch or FX8-24 blade example
  • Index

...

Este manual também é adequado para os modelos :
dados de dispositivos de processamento - HP SN6000 Stackable 8Gb 24-port Single Power Fibre Channel Switch (1.68 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias