It is strongly recommended that the filter be replaced at least every 2-3 months (depending on use) or when the heating element is starting to gather minerals on it. To Replace the Filter: 1. Switch the humidifier to 0 - off and unplug. Remove the tank, drain any water from the base, lift out the used filter, and throw it away. 2. Remove the protective bag from the new filter and pre-soak the filter under a cold running tap for 1 minute. Place the soaked filter into the base (see Figure 2) and replace the tank allowing at least 5 minutes for the water to pass before switching the unit ON (I). Cleaning and Maintenance Instruction The following maintenance procedures must be routinely followed in order to ensure proper, efficient operation of your humidifier. The unit WILL FAIL if it is not cleaned properly. Regular cleaning prevents scale build-up on the heating element and tray. It also prevents microorganisms from growing on the tray and tank. This ensures that maximum efficiency will be achieved. We cannot over-emphasize how essential proper cleaning is to the maintenance and continued use of your unit and the avoidance of algae or bacteria build-up. Regular Maintenance The frequency of maintenance will depend on the average daily use of your humidifier and the water hardness of your area. It is recommended that this procedure is carried out weekly or more regularly if necessary. 1. Before cleaning, set the control to 0 - off position and unplug outlet. 2. Remove the water tank then chamber by rotating the safety chamber from the unit's base. Now lift the tray from the base. 3. Empty water and minerals from the wash it through to remove any sediment dirt that has accumulated in the tray. NOTE: It is imperative that the tray is cleaned properly. The tray is dishwasher safe for easy cleaning (Top rack of the dishwasher only). 4. Rinse out the tank out and refill with clean cool water. 5. Wipe the heating element clean with a soft cloth after it has had a chance to cool. WARNING: If the misting chamber is left assembled to the humidifier, it may take up to an hour before the heating element is sufficiently cool to be touched. This humidifier heats the water producing a clean moisture. Some of the impurities from the water are collected in the Heating Chamber. The Electronic Thermal Control Heating element is lined with a Teflon coating that is designed to provide the easiest cleaning to prolong the operating efficiency of the humidifier. DO NOT use any metal or hard objects to clean the Heating Element. The coating can be scratched if cleaned improperly. Never use detergents, gasoline, kerosene, glass cleaner, furniture polish, paint thinner or other household solvents to clean any part of the humidifier. De-scaling Maintenance • Scale needs to be removed as it becomes noticeable. We recommend using BionaireTM Clean Away - Humidifier cleaning solution. • Apply Solution with a plastic brush to scale surfaces. Let it soak until residue is softened. For cleaning the tank, mix 2 capsules of solution with 2 litres of water. Let mixture stand for several minutes, swishing every few minutes. Drain solution and THOROUGHLY RINSE the tank. If not available follow these instructions: 1. Repeat steps 1-3 in the Maintenance section. 2. Clean the tray by partially filling the tray with 200ml of undiluted white vinegar. If the element is heavily scaled, plug the humidifier into an electrical socket and turn it ON for no longer than 15 seconds. After this time turn the humidifier OFF and outlet. Let solution stand 20 minutes, interior surfaces with a soft Dampen a cloth with undiluted white vinegar entire tray to remove scale. 3. Rinse with clean warm water to remove and the white vinegar solution before beginning to disinfect the tank. 4. Wipe the heating element clean with a soft cloth after it has had a chance to cool. Disinfect tank: 1. Fill tank with 1 teaspoon of bleach and 3.5 litres of water. 2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 3. Empty the tank after 20 minutes, and rinse well with water until the bleach smell is gone. Dry with some paper towel. 4. Refill the water tank with cool water; replace the water tank. Repeat Operating Instructions. Storage Instructions If your humidifier will not be in use for two days or more, or at the end of the season follow these instructions. 1. Clean, rinse and thoroughly dry the humidifier as directed in the De-scaling Maintenance section. DO NOT leave any water inside the base or tray. 2. Remove the reservoir cap. Do not store with the reservoir cap in place. 3. Remove and throw away the filter 4. Place the humidifier in the original carton and store in a cool, dry place. 5. Clean the humidifier before the next season begins. 6. Order a replacement filter to start the next season. SERVICE INSTRUCTIONS 1. Do NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. The in...
Este manual também é adequado para os modelos :Umidificadores - BW0M5075 (429.04 kb)