Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Hotpoint, Modelo E6002

Fabricante : Hotpoint
Arquivo Tamanho: 559.25 kb
Arquivo Nome : f845258c-31ce-4a26-9bc7-b23987759e0b.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


10 11 Installation - Model E6002 These instructions are intended for the qualified technician installing the appliance in order to insure that the installation, adjustments and maintenance procedures are performed correctly and comply with the regulations currently in effect. Important: the hob must be disconnected from the power supply before making any adjustments or performing any maintenance, etc. Installing built-in hobs The hob has a type X protection rating against overheating in compliance with regulation CEI 335-2-6. Therefore, the hob cannot be installed alongside of cabinets which are higher than the surface of the hob itself. The following precautionary measures should be observed in order to ensure proper installation: a) Hoods must be installed in compliance with the required specifications contained in the instruction manual for the hood itself. b) The built-in ceramic glass top can be installed on any counter top as long as it is 600 mm or more in width and resistant to temperatures of up to 100°C. The dimensions and the position of the hole are shown in fig.. 560 +/- 1 490 +/- 1 48 595 510 X (CEI 335-2-6) These measurements must absolutely be observed in so far as improper installation can cause the surrounding surface areas to overheat. It is recommended that the hob be installed at a distance of at least 40 mm from the back wall or other vertical surfaces to ensure that the air circulates properly over the cooking area and to avoid overheating the surrounding surfaces. A seal or gasket is provided with the hob; make sure that it adheres properly to the bottom part of the frame of the hob. The seal must fit properly around the entire hob frame and especially along the corners in order to create a seal between the counter top and the hob itself so as to prevent spills or splashes from leaking into the cabinet below. Very important It is essential to install the hob on a totally flat surtace. Any damage caused by incorrect fitting may alter the characteristics or impair performance. Insert the hob into the hole, pressing firmly around the frame to make it adhere to the counter top. Make certain that the seal around the outside edge of the hob is correctly installed in order to avoid any leakage into the cabinetry below. The four securing springs are held in place by 4 Torx screws. To remove the hob unit from its housing, undo the 2 Torx screws at the front, then the 2 Torx screws at the rear. The 4 screws should be accessible at all times for this purpose. FRONT RIGHT MOUNTING FRONT LEFT MOUNTING SEAL MOUNTING FRONT / REAR RIGHT / LEFT MOUSSE 5x8 mm HOB UNIT FAST DOWN REAR RIGHT MOUNTING WORK SURFACE REAR SPRING ASSEMBLY FRONT OF THE HOB UNIT 30 40 REAR LEFT MOUNTING c) If a wooden panel is installed beneath the hob for insulation purposes, it must be positioned at least 20 mm from the bottom part of the hob itself. Note: If the hob is installed above a built-in oven, it is preferable that the oven be installed in such a way that it is set on two strips of wood; if, on the other hand, the oven is installed on a continuous base, there must be an opening in the back of at least 45 x 560 mm. 560 mm. 45 mm. If the hob is installed above a built-in oven not equipped with a forced air cooling system, air intake and exhaust slots must be provided to ensure that the air circulates properly within the cabinet. Figures provide illustration of possible installation solutions. 10 Distance to keep between the cut-out slot and the cabinet Electrical Connection - Model E6002 Electrical Connection THIS APPLIANCE MUST BE EARTHED. The installation procedure must be carried out by a qualified electrician. The electrical safety of this appliance is guaranteed only if the appliance is correctly earthed in compliance with the standards of electrical safety. The manufacturer can under no circumstances be considered responsible for any damage that might occur due to incorrect earthing of the hob. IMPORTANT POINTS: Your hob is supplied with a special connection cable. If ever the cable is damaged it should be replaced by an authorised service engineer only. Disconnect the hob form the electrical supply before any work is carried out. To connect the supply cord, proceed as follows: -Loosen the screws on the wire clamp "V", as well as the screws for the contacts. - Insert the wires beneath the contact screws, as shown in the diagram and tighten them. - Fasten the cord with the appropriate wire clamp and close the cover. Electrical Connections: Fuse 20 A* LN * Application of the simultaneity coefficient in compliance with standard EN 335-2-6 Y-type connection in compliance with standard EN 335-2-6 Voltage and frequency of power supply: 230-240V 50-60Hz 6500W Connecting the supply cord to the electrical mains: The hob must be connected to a double pole mains switch which must be installed between the appliance and the mains..The double pole mains switch must have a minimum of 3mm of space between the contacts, be sized ...

Este manual também é adequado para os modelos :
Hobs - E600 (559.25 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias