Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Bertazzoni, Modelo K30 HER X/01

Fabricante : Bertazzoni
Arquivo Tamanho: 310.62 kb
Arquivo Nome : 5f348252-bf6f-422c-af29-282735ec1add.pdf
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


-The evacuated air must not be let into a warm air ducl. -This appliance must be connected to a system equipped with earth or ground plate. -When performing maintenance operations, disconnect the appliance from the field connection. - Do not do any flambe cooking underneath the hood. - When frying, never leave the pan alone because the cooking oil could flare up. - Clean ali the surfaces frequently to avoid danger of Fire. To do so use a cloth and or brush soaked in denatured ethyl alcohol. It is also important to remove and clean or substitute frequently the filter installed in the hood. - It advisable to utilise kitchens of the same width as the hood. Read and save these instructions PLEASE READ ALL INSTRUCTlONS CAREFULLY BEFORE COMMENCING INSTALLATlON. CHECK THAT THE ELECTRICAL SUPPLY DATA QUOTED ON THE RATlNG PLATE OF THE APPLIANCE AGREES WITH THAT OF YOUR SUPPL Y. (SEE NOTE "SAFETY REQUIREMENTS") These instructions are designed to tell you of the various technical details of your cooker hood and to make you familiar with its use. Since these instructions cover more than one type of the hood within the same series, it may be that reference is made to components that do not form part of the hood that you are installing. The hood may be used an exhaust hood. Suggestions for using the hood in exhaust position When an exhaust hood and a heat source requiring ambient air (e.g. gas, oil, coal stoves, etc.) are used at the same time, attention is required because the air necessary for combustion is exhausted from the room through the hood and, this creates depression. There is no such danger when the maximum depression in the room is 0,04mbar. In this condition no exhaust gas from the heat source is piped. To assure this condition, make openings in the room which cannot be closed (doors, windows, etc. are not sufficient) and through which the air necessary for combustion can freely flow. Note: All the exhaust ductwork in the apartment or house should be studied. In case of doubts, get advise or authorization from the person or ageney responsible for the building. When using gas burners, gas ovens, etc. as well as when using the hood in the filter version, these precautions are not necessary. Note: The efficiency of the exhaust hood decreases as the length of the ducts and number of elbows inerease. When using the exhaust version, follow these rules: Do not connect the exhaust hood to chimney, flues, and air ducts serving the room. Before venting into exhaust flues and ducts no longer in use, ask for the approval of the person or agency responsible for the building. The evacuated air must not be let into a warm air duct. For the evacuation of the exhausted air please note ufficial instructions. Installatlon The hood must be mounted over the centre of the cooking area. The minimum distances between the cooking area and the underpart of the hood are 650 mm. (25"19/32). Warning: If the room contains a flued fuel burning appliance which is not of the "balance flue" type make sure these is an adequate air inlet to the room at all times so that fumes are not drawn down the flue. N.B. The distances, however, are subject to the safety rules in effect in the various countries. Before drilling the wall make sure that no pipes or cables will be damages. If there is no outer waste-pipe for the exhaust version, an air outlet with a diameter of O160mm (6"19/64), in case you use the spigot reduction (pict.4/F) you need an exhaust outlet Attentlon: Take attention that the wall will support the weight of the cooker hood (about 30 Kg). The serews supplied with this rangehood are designed for fixing to reinforced concrete, masonry walls or hollow building blocks. Wall fixing of the eooker hood 1) Set the dislance between the cooker hob and the hood (Pict.3 ). 2) If your hood is fitted with a metal filter frame the mounting operation can be made more easily by removing it (Pict. 1) before beginning to work. The frame must be remounted when the operation is finished. 3) Drill the holes into the wall (Pict.4/N) at the right distance showen here after, and fix the cookerhood. 4) For a correct installation the hood is provided (in the rear side of its body) with one or two holes 8 mm (5/16) diam. into which one or two wall fixing screws mustI be inserted (Pict.4/O). 5) For the exhaust version, please connect the flange to an outlet ducting of 125 mm (4"591 64)diameter (Pict 4/F) - Insure that all parts are properly fixed and that it is impossible to touch moving parts. N.B.: When using a 150 mm (6”)air outlet, do not fasten the air outlet pipe with the screws, as this might cause the metal valve to malfunction. Installation ofthe pipes 1) Fix the bracket (Pict.4/C) with 2 plugs and screws (Pict.4/A) in the required hight for the pipe. 2) Screw the short pipe (Pict.4/D) with 2 screws on the braeket (Pict.4/B). 3) Insert the 2 nuts in the holes on the lower part of the long pipe. Put the long pipe o...

Este manual também é adequado para os modelos :
Fans - K36 HER X/01 (310.62 kb)
Fans - K48 HER X/01 (310.62 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias