Figure 5 Main burner flame, typical Transparentblue flame Inner flame 26024 . Monthly ..................... Main burner flames 1. See Figure 4. Remove burner input plenum cover plate “A”. 2. Visually inspect burner flames: • Proper main burner flame (see Figure 5): a. Yellow-orange streaks may appear (caused by dust). • Improper main burner flame: a. Overfired — Large flames. b. Underfired — Small flames. c. Lack of primary air — Yellow tipping on flames (sooting will occur). . Periodically.......... Test low water cutoff Test the low water cutoff periodically during the heating season, following the low water cutoff manufacturer’s instructions. Clean vent termination and air intake screens 1. Remove all lint and debris from both the boiler air intake screen and the flue discharge screen. 2. The boiler control module will sense blockage of the air intake or flue and lockout if the blockage is excessive. It will signal by flashing the appropriate indicator lights on the control board. Part number 550-141-893/0800 AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual User maintenance procedures continued . Every 6 months ........... Operate relief valve To avoid water damage or scalding due to valve operation, a metal discharge line must be connected to relief valve outlet and run to a safe place of disposal. This discharge line must be installed by a qualified heating installer or service technician in accordance with the instructions in the AHE Series 4 Boiler Manual. The discharge line must be terminated so as to eliminate possibility of severe burns should the valve discharge. 1. Before proceeding, verify that the relief valve outlet has been piped to a safe place of discharge, avoiding any possibility of scalding from hot water. 2. Read the boiler pressure/temperature gauge to make sure the system is pressurized. 3. Lift the relief valve top lever slightly, allowing water to relieve through the valve and discharge piping. 4. If water flows freely, release the lever and allow the valve to seat. Watch the end of the relief valve discharge pipe to ensure that the valve does not weep after the line has had time to drain. If the valve weeps, lift the seat again to attempt to clean the valve seat. If the valve continues to weep afterwards, contact your qualified service technician to inspect the valve and system. 5. If water does not flow from the valve when you lift the lever completely, the valve or discharge line may be blocked. Immediately shutdown the boiler, following the Operating Instructions on the inside of the jacket top panel or on pages 10 and 11 of this manual. Call your qualified service technician to inspect the boiler and system . End of season.............. Shut down procedure 1. Follow “TO TURN OFF GAS TO THE APPLIANCE” instructions found in the Operating Instructions located on the inside of the jacket top panel. You will also find these instructions on pages 9 and 10 of this manual. Use the Operating Instructions for the gas valve model installed on the boiler. 2. Do not drain system unless exposure to freezing temperatures will occur. 3. Do not drain the system if it is filled with an antifreeze solution. 4. Do not shut down boilers used for domestic water heating. They must operate year-round. Propane boilers only — Your propane supplier mixes an odorant with the propane to make its presence detectable. In some instances, the odorant can fade and the gas may no longer have an odor. • Propane gas can accumulate at floor level. Smell near the floor for the gas odorant or any unusual odor. If you suspect a leak, do not attempt to light the pilot. • Use caution when attempting to light the propane pilot. This should be done by a qualified service technician, particularly if pilot outages are common. • Periodically check the odorant level of your gas. • Inspect boiler and system at least yearly to make sure all gas piping is leak-tight. • Consult your propane supplier regarding installation of a gas leak detector. There are some products on the market intended for this purpose. Your supplier may be able to suggest an appropriate device. Part number 550-141-893/0800 AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual Operating instructions Robertshaw 7200 gas valve FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition C. Use only your hand to turn the gas control knob. Never use device which automatically lights the pilot. Do tools. If the knob will not turn by hand, don't try to repair it, not try to light the pilot by hand. call a qualified service technician. Force or attempted repair may result in a fire or explosion. B. Before OPERATING, smell all around the appliance area for gas. Be sure to smell next to D. Do not use this appliance if any part has been under water. the floor bec...

Este manual também é adequado para os modelos :
Aquecedores de Água - Series 4 (254.74 kb)
Aquecedores de Água - Series 4 (254.74 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias