Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Empire Comfort Systems, Modelo VFYM-30SO-2

Fabricante : Empire Comfort Systems
Arquivo Tamanho: 457.9 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


This appliance is for installation only in a solid fuel burning fireplace (masonry fireplace or manufactured fireplace) with a working flue and constructed of noncombustible material. Damper stop installation: A damper stop must be provided with the unit. Contact your dealer to obtain one. The damper stop must be installed as shown in (Figure 9) to prevent full closure of the fireplace damper blade and provide a minimum 29 square inch flue opening. State of Massachusetts requirement for installation of vented decorative appliance in a vented fireplace is the following: A vented decorative gas appliance must be installed in a vented fireplace only in the state of Massachusetts. The vent damper must be removed or welded permanently open. Damper Stop Installation Figure 9 12409-2-0403 Page 10 BEFORE FULLY INSTALLING THE APPLIANCE BEFORE FULLY INSTALLING THE APPLIANCE • Turn off the gas supply to the fireplace or firebox. • Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left unsealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the chimney flue damper. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. You must secure the gas log heater to the fireplace floor. If not, the entire unit may move when you adjust the controls. Movement of unit may cause shifting of the gas logs which leads to sooting and improper burning. Grate movement could cause a gas leak. Special care is required if you are installing the unit into a sunken fireplace. You must raise the fireplace floor to allow access to gas log controls. This will insure adequate air flow and guard against sooting. Raise the fireplace floor using noncombustible materials. Metal shipping plate covering burner marked REMOVE must be removed from top of burner and discarded. Burner will not operate if plate is left in place. Save for future use – when servicing fireplace. Assembly Procedure: (Figure 10) 1. Center the gas log unit in the fireplace or firebox. Make certain the front feet of the grate sit inside the front edge of the fireplace or firebox. 2. An anchor hole is provided in the two bottom side members of the grate frame. After centering the grate correctly, mark the hole positions on the fireplace/firebox floor. Drill two (2) 5/ 32" diameter holes approximately 1-1/2" deep for masonry screws or 1/8" hole for sheet metal screws. 3. Anchor the grate to the fireplace/firebox floor using the screws provided. Refer to Figure10. Proper installation of the grate is essential to prevent any movement of the gas logs and controls during operation. ANCHOR SCREWS Figure 10 12409-2-0403 Page 11 LOG PLACEMENT LOG PLACEMENT LOG PLACEMENT(Figures 12, 13, 14 and 15) SO Logs Before you begin: This unit is supplied with a set of ceramic fiber logs. Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fibers. All Logs The log system has a rear log support that rests under the rear log. This support has two holes per side that fits on the single pin covering the air shutter. A label on the rear log support indicates the location of the holes to be used. (See label). Every burner is shipped with a protective cover. This cover must be removed before log placement. The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance. Refer to Figures 12, 13, 14 and 15 for the following warning. Warning: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. PROPER INSTALLATION SEQUENCE: VFYR and VFYM-16SO (Figure 12) 1. Install rear log (#3) behind the pilot assembly directly on the pins on each side of the rear log shield. 2. The middle log (#2) will go directly on the two pins on the flat portion of the main bur...

Este manual também é adequado para os modelos :
Aquecedores de Água - VFYM-24RWO-2 (457.9 kb)
Aquecedores de Água - VFYM-16RWO-2 (457.9 kb)
Aquecedores de Água - VFYM-16SO-2 (457.9 kb)
Aquecedores de Água - VFYM-18RWO-2 (457.9 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias