Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Rinnai, Modelo Q175SP

Fabricante : Rinnai
Arquivo Tamanho: 957.68 kb
Arquivo Nome :
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


In most situations it is best to leave the pump mode OFF and let the boiler control cycle the pump as needed. During freezing temperatures it is possible (when there is no outside sensor connected), to manually place the circulation pump in constant circulation mode, thus reducing the chance of freezing pipes (garage, attic or other cold spaces / rooms) which are sensitive to frost. Operating instructions Rinnai Q-Series !! 6 Mode-button. Only for Service personel 7 Step-button. After briefly pressing, the water pressure can be retrieved. After pressing for 5 seconds it switches from the Good-state to technical read out and vice versa (see following pages); 8 Reset-button. When a fault occurs it will be shown by the flashing E (Error) with a number code after which the boiler is shut down. After pressing the reset key you can try to start the boiler again. If the error message keeps occurring contact your installer. DO NOT attempt to make repairs or remove WARNING any of the boiler panels. Contact a qualified service agency to make necessary repairs or adjustments. Operating The boiler display The boiler display Operating instructions Rinnai Q-Series Two boiler displays, “Good or Technical” see below. Good or standard read out. During this reading the display will only show what is necessary. Under normal circumstances the display will give a Good reading. In case of a fault this will be shown with, alternate display of Good, with an E or BL code. See further "Errors, maintenance and warranty" . Technical The second way is a technical read out. In normal situations the following will be shown: • on the left the status in which the boiler is active (see bottom of this page); • on the right the supply temperature in °F; • the water pressure in the installation in PSI. When a message (E or BL code) is necessary this will be shown instead of the technical read out. To switch over from the Good-state to the Technical read out (and vice versa): -Press 5 sec. on the STEP-button. Operation indication (in the first display position by technical read out) 0 1 2 3 4 5 6 7 8 9 A No heat demand Fan pre/post purge Ignition phase Burner active on central heating Burner active on DHW Fan check Burner off when room thermostat is demanding Pump overrun phase for central heating Pump overrun phase for hot water Burner off because of to high flow temperature Automatic de-aeration program (Press no button for 17 min.) Water pressure in the central heating system Water pressure in the central heating system Message ' Water pressure too low' on your RS100 thermostat. Onthedisplayofthe RS100 a low water pressure can be indicated. For further informationseetherelevant user manual. The installation will function optimally with a water pressure of between 22 and 25 PSI. If the water pressure drops below 14.5 PSI, the display will show FILL. During this message the boiler will remain functioning at a reduced level. After replenishing the system (see following chapter) just ...

Este manual também é adequado para os modelos :
Aquecedores de Água - Q130SP (957.68 kb)
Aquecedores de Água - Q130SN (957.68 kb)
Aquecedores de Água - Q175CN (957.68 kb)
Aquecedores de Água - Q175CP (957.68 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias