Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Rinnai, Modelo QPA-09-0001

Fabricante : Rinnai
Arquivo Tamanho: 4.59 mb
Arquivo Nome : 8U512001_800000026_Rev_B_Application_Manual_Rinnai_V0810_V2_(2).pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Thisdrawing is not intended to describe a complete system. It is up to thecontractor or engineer to determine the necessary components andconfiguration of the particular system to be installed. The drawing doesnot imply compliance with local building code requirements. It is theresponsibility of the engineer or contractor to ensure that the installation isin accordance with all local building codes. Confer with local buildingofficials before installation. 3 BC 53H 4 N/ O 4 N/ C 6N/ O N N/ C 6 120 VACINPUT TT COM WR 24VAC 53H 4 N/ O 4 N/ C 6N/ O N N/ C 6 120 VACINPUT TT COM WR 24VAC T stat 120V DHWPump ZonePump DHWPumpRelay HeatingPumpRelay* * May substitute for multizone relay 120VLow voltage Q boilerSingle Zone Circuit with Priority DHWNote: See pipingdiagram Single ZonePriority DHW AquastatForDHW 21 22 23 24 26 2725 B 1 2 3 4 6 75 8 9 10 12 1311 N L LN N L N CH DHW L 14 15 16 17 19 2018 N A 120VPower supply 120VExternal pump 120VExternalcontroller 120V Cylinder connectionThree way valve DHWsensor OutsideSensor BusController RoomTherm. On/Off ExternalSafetycontact 24V~ 100mA QED-09- 0001 22 Boiler Applications Manual 800000026 Rev B 4 3 2 1 Cylinder connection Q boiler 120V120V120V 120V Bus RoomExternal External DHW 24V~ Power supply External pump OutsideController Three way valve Therm. Safety controller 4 Zone Valves with Priority DHW sensor 100mA Sensor On/ Off contact DH NL NL NL N LCH N AB W D D 123456789 10 11 12 1314 15 16 17 18 19 2021 22 23 24 25 26 27 Note: 100% zone valve systemswith DHW should use only theZVC 406 AquastatForDHW TTT 24V Inputstat stat stat Outdoor Sensor C C MODE ZONE PRIORITY NORMAL RESET OFF 120V TT TT TT TT TT TT ON ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 Input ZVC 406 24V 24V FUSE ( 7 AMP MAX) SIXZONEZONE VALVE CONTROLWITH OPTIONAL PRIORITY Input MAINEXTRAN/ O COMN/ CZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ENDENDSWITCH SWITCH ZONE 6 RELAY 1234 1234 1234 1234 1234 1234 B B 1 1 1 1 222 2 333 3 Note: 4 wire zone valves may also be used System 120V Circulator Low voltage This drawing is the exclusive Rinnai America Corporation This is not an engineering drawing; it is intended only as a guide and not A A property of Rinnai America Corporation, it may not be 103 International Drive as a replacement for professional engineering project drawings. This A Peachtree City, GA 30269 drawing is not intended to describe a complete system. It is up to the reproduced or given to third Note: 1-800- 621-9419 parties. contractor or engineer to determine the necessary components and Q Series Boiler configuration of the particular system to be installed. The drawing does 4 Zone Valves with Priority DHW Switch positions and jumpers Tolerance not imply compliance with local building code requirements. It is the Fraction =±1/ 16" responsibility of the engineer or contractor to ensure that the installation is Drawn By SIZE DWG NO. REV x. x= ± 0.030 SCALE JG in accordance with all local building codes. Confer with local building x. xx=...

Este manual também é adequado para os modelos :
Aquecedores de Água - QPA-09-0002 (4.59 mb)
Aquecedores de Água - QPA-09-0003 (4.59 mb)
Aquecedores de Água - QPA-09-0004 (4.59 mb)
Aquecedores de Água - QPA-09-0005 (4.59 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias