Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação American, Modelo BTH-120 through BTH-500

Fabricante : American
Arquivo Tamanho: 665.37 kb
Arquivo Nome : 569201b4-1400-4920-b95f-7420c52c882d.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The innovative Cyclone Xi design takes performance to its highest level with efficiencies of 95% and 96%. Models are available from 120,000 BTUs and now up to 500,000 BTUs. In addition, the Cyclone Xi features an Intelligent Control System making it the smartest water heater in the industry. Cyclone Xi provides outstanding hot water output, with dramatic savings on operating costs compared to units with standard 80% efficiency. A.O. Smith’s leading-edge engineering delivers conventional power-vent or sealed combustion power direct-vent versatility, low NOx emissions and excellent space-saving characteristics. Powered anodes, standard on all Cyclone Xi models, provide superior tank protection for years of trouble free operation. INTELLIGENT CONTROL SYSTEM WITH LCD DISPLAY • Exclusive A.O. Smith designed control • Provides detailed water heater status information • Precise temperature control • Built-in diagnostics • Run histrory information SUBMERGED COMBUSTION CHAMBER, WITH HELICAL HEAT EXCHANGER COIL • Positioned in center of tank, surrounded by water to virtually eliminate radiant heat loss from chamber • Spiral heat exchanger keeps hot burner gases swirling, uses centrifugal force to maximize efficiency of heat transfer to water in tank • Spiral heat exchanger prevents scale and sediment from forming on water-side surface, which can reduce energy efficiency over time POWERED ANODES STANDARD ON ALL MODELS • Provides long-lasting tank protection in varying water conditions • Does not require maintenance or inspection PERMAGLAS® ULTRA COAT™ GLASS LINING • Exclusive process provides superior protection against corrosion • Both sides of heat exchanger coil are lined for protection against flue gas condensate inside coil MECHANICAL VENTING VERSATILITY • Conventional power-venting or sealed combustion direct venting • Vents vertically or through sidewall • Direct-vent intake and exhaust pipe can terminate separately outside building, or through single opening, using concentric vent assembly • Uses inexpensive PVC, CPVC or ABS pipe for intake and exhaust HIGH EFFICIENCY PRE-MIX POWERED BURNER • Down-fired pre-mix burner provides optimum efficiency and quiet operation • Top-mounted burner position prevents condensation from affecting burner operation BTH-120 through BTH-500 Approved, Rule 1146.2 Low NOx for California and Texas BTH-120-250BTH-300-500Page 1 of 4 December 2007R UP TO 96% THERMAL EFFICIENCY,DIRECT VENT The A.O. Smith Cyclone Xi family of products represents the industry’s most technologically advanced commercial water heaters. The innovative Cyclone Xi design takes performance to its highest level with efficiencies of 95% and 96%. Models are available from 120,000 BTUs and now up to 500,000 BTUs. In addition, the Cyclone Xi features an Intelligent Control System making it the smartest water heater in the industry. Cyclone Xi provides outstanding hot water output, with dramatic savings on operating costs compared to units with standard 80% efficiency. A.O. Smith’s leading-edge engineering delivers conventional power-vent or sealed combustion power direct-vent versatility, low NOx emissions and excellent space-saving characteristics. Powered anodes, standard on all Cyclone Xi models, provide superior tank protection for years of trouble free operation. INTELLIGENT CONTROL SYSTEM WITH LCD DISPLAY • Exclusive A.O. Smith designed control • Provides detailed water heater status information • Precise temperature control • Built-in diagnostics • Run histrory information SUBMERGED COMBUSTION CHAMBER, WITH HELICAL HEAT EXCHANGER COIL • Positioned in center of tank, surrounded by water to virtually eliminate radiant heat loss from chamber • Spiral heat exchanger keeps hot burner gases swirling, uses centrifugal force to maximize efficiency of heat transfer to water in tank • Spiral heat exchanger prevents scale and sediment from forming on water-side surface, which can reduce energy efficiency over time POWERED ANODES STANDARD ON ALL MODELS • Provides long-lasting tank protection in varying water conditions • Does not require maintenance or inspection PERMAGLAS® ULTRA COAT™ GLASS LINING • Exclusive process provides superior protection against corrosion • Both sides of heat exchanger coil are lined for protection against flue gas condensate inside coil MECHANICAL VENTING VERSATILITY • Conventional power-venting or sealed combustion direct venting • Vents vertically or through sidewall • Direct-vent intake and exhaust pipe can terminate separately outside building, or through single opening, using concentric vent assembly • Uses inexpensive PVC, CPVC or ABS pipe for intake and exhaust HIGH EFFICIENCY PRE-MIX POWERED BURNER • Down-fired pre-mix burner provides optimum efficiency and quiet operation • Top-mounted burner position prevents condensation from affecting burner ope...

Este manual também é adequado para os modelos :
Aquecedores de Água - BTH-120 through BTH-500 (665.37 kb)
Aquecedores de Água - BTH-120 through BTH-500 (665.37 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias