Log:
Downloads : 9   Arquivo Tamanho: 1 mb   Fabricante : Burnham  
Categoria : Aquecedores de Água
@name

1001 8.0 COMMISSIONING AND TESTING 8.1 Filling the Central Heating System Burner pressure test point Automatic air vent Vent cap Heat exchanger vent Pump C.H. pressure relief valveGas inlet pressure C.H. pressure gauge test point D.H.W. drain point Low water pressure switch Fig. 20 Remove the top front panel by gripping both sides and lifting forward away from main boiler assembly. Loosen the cap of the automatic air vent (fig. 20) and leave it loose. Open the central heating flow and return coc

Downloads : 4   Arquivo Tamanho: 760 kb   Fabricante : Burnham  
Categoria : Aquecedores de Água
@name

Boiler Model Number 20_PV_I -_ _ _ _ Boiler Serial Number 6_ _ _ _ _ _ _ Installation Date Heating Contractor Phone Number Address The following terms are used throughout this manual to bring attention to the presence of hazards of various risk levels, or to important information concerning product life. DANGER CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in moderate or minor injury or property damage. WARNING NOTICE Table of Contents I. Pre-Installation

Downloads : 7   Arquivo Tamanho: 477 kb   Fabricante : Burnham  
Categoria : Aquecedores de Água
@name

Model Number _ AL _______ Serial Number _ _ _ _ _ Installation Date Heating Contractor Phone Number Address ® AMERICA’S BOILER COMPANY 8140817R3-3/00 Burnham Corporation Lancaster, PA 17604-3079 IMPORTANT INFORMATION - READ CAREFULLY NOTE: The equipment shall be installed in accordance with those installation regulations required in the area where the installation is to be made. These regulations shall be carefully followed in all cases. Authorities having jurisdiction shall be consulted before

Downloads : 5   Arquivo Tamanho: 477 kb   Fabricante : Burnham  
Categoria : Aquecedores de Água
@name

To determine the approximate reduction in output from the tank use the following formula: For example, what would the first hour rating be if a model AL53A were installed with a boiler having a DOE heating capacity of 120,000 BTU/h? Increasing the boiler DOE heating capacity above the values listed in Table 3 will not increase the rating of the water heater. 3. Circulator Sizing - Refer to Table 3 for the minimum flow rate through the water heater coil and the corresponding pressure drop through

Downloads : 0   Arquivo Tamanho: 477 kb   Fabricante : Burnham  
Categoria : Aquecedores de Água
@name

Otherwise, if air noises occur during summer months the space heating system would have to be operated to purge air at the main purger. 2. For a space heating system that utilizes ZONE CIRCULATORS AND A BOILER BYPASS, refer to Figure 4. The Alliance™ connection labeled "BOILER SUPPLY" should be piped to the boiler supply piping as close to the boiler as possible and especially before the bypass piping. Mount the circulator as close as possible to the water heater making sure the flow arrow point

Downloads : 0   Arquivo Tamanho: 3 mb   Fabricante : Burnham  
Categoria : Aquecedores de Água
@name

Boiler Company, Inc. Lancaster, Pennsylvania hereby extends the following limited warranties to the original owner of a residential grade water or steam boiler or U.S. Boiler Company, Inc. supplied parts and/or accessories manufactured and shipped on or after July 1, 2008: ONE YEAR LIMITED WARRANTY ON RESIDENTIAL GRADE BOILERS AND PARTS / ACCESSORIES SUPPLIED BY U.S. BOILER COMPANY, INC. U.S. Boiler Company, Inc. warrants to the original owner that its residential grade water and steam boilers a

Downloads : 4   Arquivo Tamanho: 7 mb   Fabricante : Burnham  
Categoria : Aquecedores de Água
@name

5. When the call for heat is satisfied, the damper relay coil is de-energized - closing contacts which energize the damper motor. This causes the damper to close. When the damper blade reaches the fully closed position, the damper motor is de-energized. POWER FAILURE - The damper blade will stop in the position it was in when power failed. (Combustion can never take place unless the damper blade is in the fully open position). G. Sequence of Operation and Wiring. Refer to Table 10 for the approp

Downloads : 1   Arquivo Tamanho: 590 kb   Fabricante : Burnham  
Categoria : Aquecedores de Água
@name

When you select Burnham, you’re buying more than just an appliance. Every product is crafted with the highest quality materials and components – by experts committed to delivering the absolute best performance. With Burnham products, you can count on the best craftsmanship, ingenuity, and customer service and support that the industry has to offer. CHG “Condensing, High Efficiency, Gas” Boilers Today’s lifestyles have created ever increasing demands for abundant supplies of comfortable space hea

Downloads : 44   Arquivo Tamanho: 477 kb   Fabricante : Burnham  
Categoria : Aquecedores de Água
@name

Normally open contacts open, stopping boiler operation. Domestic hot water priority only: normally closed contacts close, returning boiler control to space heating. D. b. Adjusting to a higher temperature may not immediately affect water temperature. If a heat- up cycle begins, go to step 3. If a heat-up cycle does not begin, draw sufficient water or allow the water heater to sit until a heat-up cycle is initiated. Repeat step 3. To Shut-off Water Heater C. Water Temperature Adjustment 1. The aq

Downloads : 6   Arquivo Tamanho: 125 kb   Fabricante : Burnham  
Categoria : Aquecedores de Água





categorias