Log:
Assessments - 6, GPA: 3.3 ( )

Instruções de Operação Sharp, Modelo KC-860E

Fabricante : Sharp
Arquivo Tamanho: 11.54 mb
Arquivo Nome :
Língua de Ensino: ruenfrdenl
Fotos e especificações  Sharp  KC-860E
Ir para baixar



Facilidade de uso


These impurities (calcium, etc.) are due to the impurities contained in tap water; this is not a defect. Replace the Humidifying Filter when it is covered completely in white deposits. m o [reset,]; E-14 KC-840E_Eng2.indd 14 o 08.10.10 9:23:32 A M r FILTER REPLACEMENT GUIDELINES Filter life will vary depending on the room environment, usage, and location of the unit. If dust or odours persist, replace the filters. (Refer to “Please read before operating your new Air Purifier”) Guide for filter replacement timing HEPA Filter Up to 5 years after opening Filter life can be greatly reduced depending on the room environment. Cigarette smoke, pet dander, and other airborne particles can reduce filter life. Check filters regularly and replace as necessary. Washable Deodorizing Filter The filter can be repeatedly used after washing, or it can be replaced. Humidifying Filter Up to 2 years after opening Filter life can be greatly reduced depending on the room environment. Even if 2 years have not passed, replace the Humidifying Filter if you notice the following: • Mineral deposits (white, black, or red masses) which are not removed after cleaning or the Humidifying Filter is still dirty. • Filter is severely damaged or warped. Replacement Filters • HEPA Filter: lunit Model FZ-C150HFE (for KC-860E) FZ-C100HFE (for KC-850E) FZ-C70HFE (for KC-840E) • Washable Deodorizing Filter: lunit Model FZ-C150DFE (for KC-860E) FZ-C100DFE (for KC-850E) FZ-C70DFE (for KC-840E) • Humidifying Filter: lunit Model FZ-C100MFE Replacing the Filters 1. Replace filters according to the instructions provided with the replacement filters. 2. Use the date labels as a reminder for when the filters should be replaced. Disposal of Filters Please dispose of used filters according to any local laws and regulations. HEPA Filter materials: • Filter: Polypropylene • Frame: Polyester Washable Deodorizing Filter materials: • Polyester, Rayon, Activated charcoal Humidifying Filter materials: • Rayon, Polyester E-15 KC-840E_Eng2.indd 15 ■e- 08.10.10 9:23:32 A M 1 ■■■ Q im m ■r 1 TROUBLESHOOTING IB 1 Before calling for service, please review the Troubleshooting chart below, since the problem may not be a unit malfunction. r SYMPTOM \ REMEDY (not a malfunction) Odours and smoke are not removed. • Clean or replace the filters if they appear to be heavily soiled. (See E-11,E-12,E-14) The Front Monitor illuminates green even when the air is impure. • The air could be impure at the time the unit was plugged in. Unplug the unit, wait one minute, and plug the unit in again. The Front Monitor illuminates orange or red even when the air is clean. • Sensor operation is affected if the dust sensor openings are dirty or clogged. Gently clean the dust sensors (See E-11). A clicking or ticking sound is heard from the unit. • Clicking or ticking sounds may be audible when the unit is generating ions. The discharged air has an odour. • Check to see if the filters are heavily soiled. • Clean or replace the filters. • Plasmacluster Air Purifiers emit small traces of ozone which may produce an odour. The unit does not operate when cigarette smoke is in the air. • Is the unit installed in a location that is difficult for the sensor to detect cigarette smoke? • Are the dust sensor openings blocked or clogged? (In this case, clean the openings.) (See E-11) Filter Indicator Light is illuminated. • After replacing filters, connect the power cord to an outlet and press the Filter Reset Button. (See E-11) The Front Monitor are turned off. • Check to see if the Lights OFF Mode selected. If so, then press the Lights Control Button to activate the indicator lights. (See E-10) The Water Supply Indicator Light does not illuminate when the tank is empty. • Check Styrofoam float for impurities. Clean the Humidifying-Tray. Ensure unit is located on a level surface. Water lever in the tank does not decrease or decreases slowly. • Check to see if the Humidifying Tray and Water Tank are correctly installed. Check the Humidifying Filter. • Clean or replace the filter when it is heavily soiled (See E-14 and E-15). The Front Monitor lights change colour frequently. V • The Front Monitor lights automatically change colours as impurities are detected by the dust sensor and odour sensor. _J E-16 KC-840E_Eng2.indd 16 ■e- 08.10.10 9:23:33 A M ■ ■■ ERROR DISPLAY KC-850E^KC-860E If error occurs again, contact the Sharp Service Centre. f DIGITAL INDICATION LAMP INDICATION ERROR DETAILS REMEDY E? Flashing of the Clean Air & Humidify Indicator Light. Abnormal humidity filter Verify if the Humidifying Filter, Humidifying Tray and Water Tank are properly installed and then turn power ON again. r 1 <_ 1 Flashing of the Fan Speed Indicator Light ' © '. Abnormal fan motor Turn power OFF to cancel the error display, wait one minute, and then turn power ON. C3 Abnormal temperature-humidity sensor Unplug the unit, wait one minute, and plug the...

Este manual também é adequado para os modelos :
Air - KC-840E (11.54 mb)
Air - KC-850E (11.54 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias