Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Lifebreath, Modelo 500ERV

Fabricante : Lifebreath
Arquivo Tamanho: 968.21 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


This is the factory default setting. Follow the instructions found on the HRV/ERV door to select desired mode and speed, or refer to the instructions found on the following page. Removing and relocating the Control Pad The Control Pad can be removed and installed in a remote location (100’ wire length max). The Control Pad can be installed in a 2x4 box with a “Decora” type cover plate or can be installed in the optional “Ventilation Dehumidistat” or “Air Sentry”. When the Control Pad is installed in a remote location, all optional controls will still be wired to the Control Module on the HRV/ERV. When remotely mounted on its own, the Control Pad is wired to the Control Module by 3 wire (min. 20 gauge). Connect the colour coded terminals to the corresponding terminals on the Control Module. When the Control Pad is remotely mounted in the Ventilation Dehumidistat or Air Sentry, refer to optional controls page for wiring requirements. Self Test Each time the HRV/ERV is powered/energized the self test function will automatically initiate. During the self test the HRV/ERV will cycle through all the speeds available (1-5), test the damper motor operation and will default back to the previous mode/speed selection, (factory default is Speed 1). Total self test duration is approximately 1 min. 30 sec. Automatic Defrost Operation (Not on all models) The advanced technology of the digital microprocessor automatically activates the defrost system only as it is needed. To be an efficient heat recovery device, the HRV/ERV must effectively provide for core defrost as well as providing efficient heat exchange. As outdoor conditions cool, the temperature sensor (thermistor) tracks the supply air temperature. The thermistor then sends its signal to the microprocessor (circuit board) which initiates only the defrost cycle time required to clear the core. On recirculating defrost models, the core is defrosted when the supply air port is automatically blocked off and exhaust air is redirected back through the HRV/ERV. On damper defrost models, the core is defrosted when the supply air port is automatically blocked off and the warm air surrounding the HRV/ERV is drawn in through the defrost port. The mode indicator will flash RED during the defrost cycle. This dramatic advance makes more energy available for recovery as the unit spends less time in defrost mode. By optimizing the defrost cycle, the HRV/ERV combines money saving performance with a well designed and reliable control system. FUNCTION & CONTROL Model 500 Only Glossary DEFROST MODE - to ensure reliable operation during cold weather, the HRV/ERV will automatically cycle through its defrost mode as needed. (not on all models) DEHUMIDISTAT - a control device that senses the amount of moisture in the air and will activate high speed fan operation when the air moisture level exceeds the control setting. The optimum air moisture level (or relative humidity [Rh]) in the typical home is in the range of 30 to 40% Rh. RESET - whenever resetting of the HRV/ERV is required, simply disconnect power for 30 seconds. STANDBY MODE - the HRV/ERV is energized and waiting for fan operation to be initiated by a remote device or manual override. THERMISTOR - the HRV/ERV's temperature sensor which measures electrical resistance in a known manner, as outdoor temperatures fluctuate. ControlAir 15 Exploded view Control Module Control Pad 21 To select mode of operation for ControlAir 15 Model 500 Only Press and hold the fan selection button on the Control Pad. After 5 seconds the control will begin to cycle each mode holding each for 2 seconds. Release the button when the desired mode of operation is reached. Modes of Operation LED Indication OFF No LED’s illuminated HRV/ERV is off, no controls will initiate operation. Standby / On Steady Green LED and Yellow LED to indicate speed HRV/ERV will run at speed selected in ventilation mode. Standby mode is indicated by no speed indicator illuminated. Optional remote controls will override standby or selected speed into high speed. 20 On / 40 Off Flashing Green LED and Yellow LED to indicate speed HRV/ERV will operate in ventilation mode at speed selected for 20 minutes and OFF for 40 minutes. To select speed Momentarily press fan selection button and release. HRV/ERV will move into next speed. OFF is indicated by no yellow LED illuminated. Speed 1 is the first yellow LED. Speed five is indicated by a flashing speed 4 LED. Automatic Defrost During cold outdoor conditions the HRV/ERV will occasionally go into an automatic defrost function, which will prevent ice from forming on the core. Defrost is indicated by a flashing Red LED indicator. 22 PITOT TUBE AIR FLOW BALANCING It is necessary to have balanced air flows in an HRV/ERV. The volume For general balancing it is sufficient to move the pitot tube around in of air brought in from the outside must equal the volume of air exhausted by the unit. If the air flows are not properly balanced, then; • Th...

Este manual também é adequado para os modelos :
Air - 1200ERV (968.21 kb)
Air - 1200FD/DD (968.21 kb)
Air - 700ERV (968.21 kb)
Air - 700FD/DD (968.21 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias