Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Philips, Modelo HX5610/04

Fabricante : Philips
Arquivo Tamanho: 1.12 mb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


When not in use, keep your Sonicare in the charger base to maintain a full batter y charge. 14 EngliSh Cleaning By following these simple steps, you should get years of worry-free brushing: 1 Rinse brush head and bristles after each use. 2 Clean the brush head at least once per week, including under the removable nut. To remove the nut: Press down gently on the white area. , Avoid using sharp objects to push on the seal as this may cause damage. Pull the nut up over the top of the brush head , To replace the nut, slip the nut over the brush head shaft and pull until it clicks back on. EngliSh 15 3 4 Clean and dry the handle periodically. Clean the charger base periodically. UNPLUG the charger before cleaning. After cleaning the charger base, completely dry the charger before plugging it into an electrical outlet. Mild soap, water and a moist cloth are recommended for cleaning your Sonicare. Additional Cleaning Tip: -The Sonicare handle is dishwasher safe. Remove the brush head and charger before placing the handle only in the top rack of dishwasher. -NOTE: Brush heads and charger base should never be placed in the dishwasher. Storage If the product is not to be used for an extended period of time it should be unplugged from the electrical outlet, cleaned, stored in a cool and dr y area away from direct sunlight.The cord wrap can be used to store power cord in an organized manner. replacement Brush head Replace Sonicare brush heads ever y 3 months to achieve optimal results. 16 EngliSh Environment HANDLE CONTAINS NICKEL METAL HYDRIDE BATTERIES. BATTERIES MUST BE RECYCLED OR DISPOSED OF PROPERLY. -The rechargeable batter y inside your Sonicare cannot be replaced, but is easy to remove for recycling. At the end of product life and prior to disposal, please remove the rechargeable batter y from the handle by following the instructions below. -Do not throw away the appliance with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preser ve the environment. -If you have any recycling questions, contact your local waste management office. removing the batteries Please note that this process is NOT reversible. To remove the batteries yourself, you will need a flat-head (standard) screwdriver and a small towel. Basic safety precautions should be obser ved when following the procedure outlined below. Be sure to protect your eyes, hands, fingers and the surface on which you are working. 1 Deplete the battery of any charge by removing the handle from the charger, turning the Sonicare on and allowing it to run until it stops. Repeat this step until the Sonicare will no longer operate. 2 2 EngliSh 17 3 4 5 6 Insert a screwdriver into one of the slots located near the top portion of the handle, push the screwdriver blade into the handle as far as it will go, and twist the blade.The housing will begin to split. Remove the screwdriver and repeat the above instruction using the other slot located on the opposite side of the handle.Twist the blade and the housing will continue to split. Now, insert the screwdriver into the middle slot located on the top front part of the handle as shown and push the blade in as far as it will go. Now use the screwdriver as a lever to pry the 2 handle sections apart. Pull the 2 handle sections completely apart. 18 EngliSh 7 Insert the screwdriver underneath the electronic circuit board in multiple places. 8 Twist and pry the electronic circuit board loose until it is completely separated from the handle. 9 Pry the 2 AA-sized cylindrical nickel metalhydride batteries loose by inserting the screwdriver on the sides of the two batteries in the locations shown in the figure. 10 Use a twisting and prying motion to break the glue bond around the batteries.The 2 batteries are joined together with glue and will be lifted out together. EngliSh 19 guarantee and service Philips guarantees its products for two years after the date of purchase. Defects due to faulty materials and workmanship will be repaired or replaced at Philips expense provided that convincing proof of purchase in the qualifying period is provided. Use of unauthorized replacement par ts will void this warranty. Contact our Customer Ser vice Center at 1-800682- 7664 (Nor th America), outside Nor th America contact your local Philips Customer Care Center. Internet information: (Nor th America) or (outside Nor th America). WarranTY EXClUSionS What is not covered under warranty: -Brush heads -Damage caused by use of unauthorized replacement par ts. -Damage caused by misuse, abuse, neglect, alterations or unauthorized repair. -Normal wear and tear, including chips, scratches, abrasions, discoloration or fading. iMpliEd WarranTiES ANY IMPLIED WARRANTIES, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIMITED TO THE DURATION OF THE EXPRESS WARRANTIES SET FORTH ABOVE. SOME STAT...

Este manual também é adequado para os modelos :
Escovas de dentes - HX5610/03 (1.12 mb)
Escovas de dentes - HX5610/01 (1.12 mb)
Escovas de dentes - HX5350/02 (1.12 mb)
Escovas de dentes - HX5910 (1.12 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias