Facilidade de uso
IMPORTANT: CHECK YOUR LOCAL ELECTRICAL CODES. IF YOUR LOCAL CODE REQUIRES PERMANENT WIRING, USE THE SPECIFICATIONS CALLED FOR AND INSTRUCTIONS ILLUSTRATED. Permanent Wiring Procedure 1. Ensure power cord is disconnected from electrical power. 2. Cut power cord 1/2” – 1” from strain relief/bushing. 3. Use needle nose pliers to remove strain relief bushing from frame. Squeeze tabs in on underside of bushing and work bushing out of hole. 4. Pull or strip off remaining section of outer insulation from power cord. 5. Remove lens by pressing up on both sides of the bottom of the lens at the junction of the housing, releasing the locking tabs, and pulling forward; remove light bulb (if installed). 6. Remove the housing from the chassis by removing the screw securing the housing to the chassis. Press on the locking tabs and slide the cover off the chassis. 7. Pull the three wires into the opener; strip 1/2” of insulation from the black, white, and green wires. 8. Using wire nuts for 14-18 AWG wire, connect the black wire to black wire, the white wire to white wire and the green wire to green wire. Make sure connections are secure. 9. Replace opener cover. Reconnect the power at the fuse/ breaker box, as soon as power is applied to the unit, the light on the opener will blink once to indicate a successful self check of the controls. WARNING Live & Neutral Ground .. Opener 1/2” To 1” Power Cord Strain Relief Bushing Strain Relief Bushing Screw Lens Light Bulb Tabs Tab Chassis Tabs Housing Wire Nuts Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at 21 U-BAR Door Bracket Male Part Of Top Door Bracket Section Align Tab With Center Line Of Top Section Or Ubar Mounting Door Bracket To A 9700 Series Door IMPORTANT: WHEN CONNECTING A TROLLEY TYPE GARAGE DOOR OPENER TO A 9700 SERIES DOOR, A WAYNEDALTON OPENER/TROLLEY BRACKET MUST BE SECURELY ATTACHED TO THE TOP SECTION OF THE DOOR, ALONG WITH ANY U-BARS PROVIDED WITH THE DOOR. THE INSTALLATION OF THE OPENER MUST BE ACCORDING TO MANUFACTURER’S INSTRUCTIONS AND FORCE SETTINGS MUST BE ADJUSTED PROPERLY. Locate the center of the top section or factory attached u-bar as shown in FIG 1.1. FOR TOP SECTION WITH U-BAR: Remove and retain 4-6 screws from the center of the u-bar, allowing the door bracket to slide between the section and the u-bar. Position the door bracket until it seats on the male part of the section as shown in FIG 1.2. The door bracket must be centered and positioned on the top section so it bridges the transition point of the section thickness. Attach the door bracket using 1/4” - 14 x 5/8” self tapping screws as shown in FIG 1.4. Re-attach the u-bar using (2) 1/4” - 20 x 11/16” self drilling screws through the door bracket as shown in FIG 1.3. Finish re-attaching the u-bar using the self tapping screws removed previously. FOR TOP SECTION WITHOUT U-BAR: Position the door bracket until it seats on the male part of the section as shown in FIG 1.2. The door bracket must be centered and positioned on the top section so it bridges the transition point of the section thickness. Attach the door bracket using 1/4” - 14 x 5/8” self tapping screws as shown in FIG 1.4. NOTE: After completing this step, continue with Step 7. .. Tools Needed: Power Drill 7/16” Socket Driver Door Bracket (2) 1/4”-20 x 11/16” Self Drilling Screws (8) 1/4”-14 x 5/8” Self Tapping Screws Door Bracket Door Bracket Top Section With U-Bar Top Section Without U-Bar Door Bracket FIG. 1.1 FIG. 1.2 FIG. 1.3 FIG. 1.4 OPTIONAL INSTALLATIONS Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at 22 Mounting Door Bracket To A (9100, 9400, 9600, 5120 & 5140 Series Door) IMPORTANT: WHEN CONNECTING A TROLLEY TYPE GARAGE DOOR OPENER TO THE ABOVE LISTED DOORS, A WAYNEDALTON OPENER/TROLLEY BRACKET MUST BE SECURELY ATTACHED TO THE TOP SECTION OF THE DOOR, ALONG WITH ANY U-BARS PROVIDED WITH THE DOOR. THE INSTALLATION OF THE OPENER MUST BE ACCORDING TO MANUFACTURER’S INSTRUCTIONS AND FORCE SETTINGS MUST BE ADJUSTED PROPERLY. Locate the center of the top section and seat the door bracket on male part of the top section. The door bracket must be centered and positioned on top section so it bridges the transition point of the section thickness, as shown in FIG. 1.1 and 1.2. Install (2) #12 x 1/2” phillips head screws on the opposite side of door bracket, as shown in FIG. 1.3. If initially supplied ubar is on the door, clamp door bracket to u-bar, as shown in FIG. 1.4. First attach (3) 1/4” - 14 x 5/8” self-tapping screws to the door bracket, as shown in FIG. 1.5. Then attach (2) 1/4” - 14 x 5/8” self-tapping screws to the ...
Este manual também é adequado para os modelos :Portão automático - PRODRIVE 3220C (4.85 mb)
Portão automático - PRODRIVE 3220C-Z (4.85 mb)
Portão automático - PRODRIVE 3221C (4.85 mb)
Portão automático - PRODRIVE 3221C-Z (4.85 mb)