|
Facilidade de uso
In all situations, clearances to combustibles must be maintained. Failure to observe clearances to combustibles may result in property damage, severe injury, or death. Minimum clearances must be maintained from vehicles parked below the heater. Signs should be posted in storage areas to specify maximum stacking height to maintain required clearances to combustibles. Caution should be used when running the system near combustible materials such as wood, paper, rubber, etc. Consideration should be given to partitions, storage racks, hoists, building construction, etc. TABLE 1 gives minimum acceptable clearances to combustibles. Clearances as shown in TABLE 1 are not for use in four-sided enclosures. Clearances To Combustibles Figure 1: Clearances To Combustibles (Refer to TABLE 1 on page 9) A A C C D F E Standard Reflector 45° Reflector Tilt A D C A “U”-Tube, Standard A F F C “U”-Tube, Opposite 45° E F “U”-Tube, Full 45° C B B Front and Back Clearance Parts List for Packaged Ener-Radiant XL Tube Heaters Item Stock# Description Number Required 1 F107400XL ERXL-60 NG COMP / 20’ X 2 F107401XL ERXL-60 LP COMP / 20’ X 3 F107402XL ERXL-80 NG COMP / 30’ X 4 F107403XL ERXL-80 LP COMP / 30’ X 5 F107412XL ERXL-80S, NG COMP / 20’ X 6 F107413XL ERXL-80S, LP COMP / 20’ X 7 F107414XL ERXL-100S, NG COMP / 30’ X 8 F107415XL ERXL-100S, LP COMP / 30’ X 9 F102650XL ERXL-60 NG / BRN & Cont Box 1 10 F102651XL ERXL-60 LP / BRN & Cont Box 1 11 F102652XL ERXL-80S, ER3-80 LP / BRN & Cont Box 1 1 12 F102653XL ERXL-80S, ER3-80 LP / BRN & Cont Box 1 1 13 F102654XL ERXL-100S / BRN & Cont Box / NG 1 14 F102655XL ERXL-100S / BRN & Cont Box / LP 1 15 F106401XL ERXL-100S / TUBE SYS ONLY / 30’ 1 1 16 F106404XL ERXL-60, 80S / TUBE SYS ONLY / 30’ 1 1 1 1 17 F106405XL ERXL-80 / TUBE SYS ONLY / 30’ 1 1 18 00418A REFLECTOR / T.H. 2 2 3 3 2 2 3 3 19 03445 TURBULATOR BAFFLE 10’ 1 1 1 1 1 1 20 03447 TURBULATOR BAFFLE 5’ 1 1 21 06413 TUBE H.E. 4” O.D. X 10’ 1 1 2 2 1 1 2 2 22 14585 HANGER / TUBE & REFLECTOR 4 4 6 6 4 4 6 6 23 02753 FRONT CASING 1 1 1 1 1 1 1 1 24 14312 TUBE COUPLING ASSEMBLY 1 1 2 2 1 1 2 2 *Items 15, 16, 17 include the following items: 18, 19, 20, 21, 22, 24. 1822910111224211921232418242124212218202124212123131421231112 Figure “A” - Assembly Model ERXL-60, ERXL-80S Figure “B” - Assembly Model ERXL-80 Figure “C” - Assembly Model ERXL-100s Parts List for Packaged Ener-Radiant XL Tube Heaters Item Stock# Description Number Required 1 F107404XL ERXL-100 NG COMP / 40’ X 2 F107405XL ERXL-100 LP COMP /40’ X 3 F107406XL ERXL-125 NG COMP / 50’ X 4 F107407XL ERXL-125 LP COMP / 50’ X 5 F107408XL ERXL-150, NG COMP / 50’ X 6 F107409XL ERXL-150, LP COMP / 50’ X 7 F107420XL ERXL-175, NG COMP / 50’ X 8 F107421XL ERXL-175, LP COMP / 50’ X 9 F107416XL ERXL-125S, LP COMP / 40’ X 10 F107417XL ERXL-125S, LP COMP / 40’ X 11 F107418XL ERXL-150L, LP COMP / 60’ X 12 F107419XL ERXL-150L, LP COMP / 60’ X 13 F107422XL ERXL-175L, LP COMP / 60’ X 14 F107423XL ERXL-175L, LP COMP / 60’ X 15 F102654XL ERXL-100 NG / BRN & Cont Box 1 16 F102655XL ERXL-100 LP / BRN & Cont Box 1 17 F102656XL ERXL-125S, ERXL-125 NG / BRN & Cont Box 1 1 18 F102657XL ERXL-125S, ERXL-125 LP / BRN & Cont Box 1 1 19 F102658XL ERXL-150L, ERXL-150 NG / BRN & Cont Box 1 1 20 F102659XL ERXL-150L, ERXL-125 LP / BRN & Cont Box 1 1 21 F102660XL ERXL-175L, ERXL-175 NG / BRN & Cont Box 1 22 F102661XL ERXL-175L, ERXL-175 LP / BRN & Cont Box 1 1 23 F106403 ERXL-150L / TUBE SYS / 60’ 1 1 24 F106406 ERXL-100, ERXL-125S / TUBE SYS / 40’ 1 1 1 1 25 F106407 ERXL-125, ERXL-150 / TUBE SYS / 50' 1 1 1 1 26 00418A REFLECTOR / T.H. 4 4 5 5 5 5 4 4 6 6 27 06413 TUBE H.E. 4” O.D. X 10’ 3 3 4 4 4 4 3 3 5 5 28 06423 TRANSITION TUDE ASSEMBLY 1 1 1 1 1 1 1 1 1 1 29 14585 HANGER / TUBE & REFLECTOR 8 8 10 10 10 10 8 8 12 12 30 14587 TUBE SUPPORT - 5' 1 1 1 1 1 1 1 1 1 1 31 14612 TUBE COUPLING ASSEMBLY 3 3 4 4 4 4 3 3 5 5 *Items 23, 24,25 include the following items: 26, 27, 28, 29, 30. 2828272628272627302729211920223027292122302729192018172615161718 Figure “D” - Assembly Model ERXL-100, ERXL-125S Figure “E” - Assembly Model ERXL-125, ERXL-150, ERXL-175 Figure “F” - Assembly Model ERXL-150L, 175L SECTION 3 Installation & Assembly FIGURE 2: Ener-Radiant XL Overview Key Burner Housing Must always be installed horizontally. Tube and Reflector Hanger Install immediately after first coupling. Tube and Reflector Hanger Suspend system from these hangers. Minimum two (2) required per tube. Reflectors Alternate overlap as shown on overview. Length of reflector and amount of overlap is indicated. Heat Exchange Tubes Supplied in 10 ft. lengths. 10' 2=1/2" ALUMINIZED Tube Coupling Assembly Coupling should be oriented with slide bar on top, and all couplings should “point” in the same direction. Turbulator Assembly Ene...
Este manual também é adequado para os modelos :Aquecedores a gás - ERXL-100S (1.11 mb)
Aquecedores a gás - ERXL-125 (1.11 mb)
Aquecedores a gás - ERXL-125S (1.11 mb)
Aquecedores a gás - ERXL-150 (1.11 mb)