Log:
Assessments - 4, GPA: 3.3 ( )

Instruções de Operação Antec, Modelo Lenze SV01B

Fabricante : Antec
Arquivo Tamanho: 944.79 kb
Arquivo Nome :
Língua de Ensino:
Ir para baixar



Facilidade de uso


(2) UL Class CC or T fast-acting current-limiting type fuses, 200,000 AIC, preferred. Bussman KTK-R, JJN or JJS or equivalent. ( ) Thermomagnetic type breakers preferred. Observe the following when using Ground Fault Circuit Interrupters (GFCIs): • Installation of GFCI only between supplying mains and controller. • The GFCI can be activated by: - capacitive leakage currents between the cable screens during operation (especially with long, screened motor cables) -connecting several controllers to the mains at the same time -RFI filters ENGLISH Installation 3.2.3 Control terminals Terminal Data for control connections 1 Digital Input: Start/Stop input resistance = 4. k. 2 Analog Common 5 Analog Input: 0... 0 VDC input resistance: >50 k. 6 Internal DC supply for speed pot + 0 VDC, max. 0 mA 25 Analog Input: 4...20 mA input resistance: 250. 4 Digital Reference/Common + 5 VDC / 0 VDC, depending on assertion level 11 Internal DC supply for external devices + 2 VDC, max. 50 mA 13A Digital Input: Configurable with P 2 input resistance = 4. k.13B Digital Input: Configurable with P 22 13C Digital Input: Configurable with P 2 14 Digital Output: Configurable with P 42 DC 24 V / 50 mA; NPN 30 Analog Output: Configurable with P 50…P 55 0… 0 VDC, max. 20 mA 16 Relay output: Configurable with P 40 AC 250 V / A DC 24 V / 2 A … 240 V / 0.22 A, non-inductive17 6 25 4 11 13A 13B 13C 1751 2 14 30 16 AOUTDIGOUT2k … 10k +10 VAINAINCOM COM ALsw 252 4 … 20 mA 52 0 … 10 V 0 … 5 V 1 2 4 13A 13B 13C +12 VDC - 0 % … +30 VDC + 0 % ALsw +15V 1 2 4 13A 13B 13C ALsw COM PNP NPN4.5 lb-in (0.5 Nm) 0.25 in (6 mm) AWG 26…16 (<1mm.) V0 09 Assertion level of digital inputs The digital inputs can be configured for active-high or active-low by setting the Assertion Level Switch (ALsw) and P 20. If wiring to the drive inputs with dry contacts or with PNP solid state switches, set the switch and P 20 to “High” (+). If using NPN devices for inputs, set both to “Low” (-). Active-high (+) is the default setting. HIGH = + 2 … + 0 V LOW = 0 … + V Note An fault will occur if the Assertion Level switch (ALsw) position does not match the parameter P 20 setting and P 00 or any of the digital inputs (P 2 ...P 2 ) is set to a value other than 0. 2 ENGLISH Commissioning 4 Commissioning 4.1 Local Keypad & Display FWDAUTOREVSTOPRUN V0 05 RUNSTOP START BUTTON: In Local Mode (P 00 = 0, 4), this button will start the drive. STOP BUTTON: stops the drive, regardless of which mode the drive is in. WARNING! When JOG is active, the STOP button will not stop the drive! ROTATION: In Local Mode (P 00 = 0, 4), this selects the motor rotation direction: -The LED for the present rotation direction (FWD or REV) will be on -Press R/F; the LED for the opposite rotation direction will blink -Press M within 4 seconds to confirm the change -The blinking direction LED will turn on, and the...

Este manual também é adequado para os modelos :
Fonte de alimentação e fonte de alimentação - Lenze V0100 (944.79 kb)
Fonte de alimentação e fonte de alimentação - Lenze V0100 (944.79 kb)
Fonte de alimentação e fonte de alimentação - Lenze V0100 (944.79 kb)
Fonte de alimentação e fonte de alimentação - Lenze SV01B (944.79 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias