Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Antec, Modelo Lenze V0100

Fabricante : Antec
Arquivo Tamanho: 944.79 kb
Arquivo Nome : df22161b-b9de-4170-aa0f-a71aacc03312.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Emergency Stops, over-speed protection, acceleration and deceleration limits, etc must be made by other devices to ensure operation under all conditions. The drive does feature many protection devices which are aimed at protecting the drive and the driven equipment by generating a fault and shutting the drive and motor down by removing power. Mains power variances can also result in shutdown of the drive. When the fault condition disappears or is cleared, the drive can be configured to automatically restart, it is the responsibility of the user and/or OEM and/or integrator to ensure that the drive is configured for safe operation. ENGLISH Safety information All safety information given in these Operating Instructions have the same layout: Signal Word! (characterizes the severity of the danger) Note (describes the danger and informs on how to proceed) Icon Signal Words Warning of hazardous electrical voltage DANGER! Warns of impending danger. Consequences if disregarded: Death or severe injuries. Warning of a general danger WARNING! Warns of potential, very hazardous situations. Consequences if disregarded: Death or severe injuries. Warning of damage to equipment STOP! Warns of potential damage to material and equipment. Consequences if disregarded: Damage to the controller/drive or its environment. Information Note Designates a general, useful note. If you observe it, handling the controller/drive system is made easier. Note for UL approved system with integrated controllers: UL warnings are notes which apply to UL systems. The documentation contains special information about UL. • Suitable for use on a circuit capable of delivering not more than 200,000 rms symmetrical amperes, at the maximum voltage rating marked on the drive. • Use minimum 75 °C copper wire only. • Shall be installed in a pollution degree 2 macro-environment. Warnings! Operation Systems including controllers must be equipped with additional monitoring and protection devices according to the corresponding standards (e.g. technical equipment, regulations for prevention of accidents, etc.). The controller may be adapted to your application as described in this documentation. DANGER! • After the controller has been disconnected from the supply voltage, live components and power connection must not be touched immediately, since capacitors could be charged. Please observe the corresponding notes on the controller. • Please close all protective covers and doors prior to and during operation. • Do not cycle input power to the controller more than once every two minutes. ENGLISH Technical data 2 Technical data 2.1 Standards and application conditions Conformity CE Low Voltage Directive (7 /2 /EEC) Approvals UL 508C Underwriters Laboratories - Power Conversion Equipment Input voltage phase imbalance < 2% Humidity < 95% non-condensing Transport -25 … +70°C Temperature range Storage -20 … +70°C Operation - 0 … +55°C (with 2.5%/°C current derating above +40°C) Installation height 0 … 4000m a.m.s.l. (with 5%/ 000 m current derating above 000m a.m.s.l.) Vibration resistance acceleration resistant up to .0g Earth leakage current > .5 mA to PE Enclosure IP 2 / IP / NEMA Protection measures against short circuit, earth fault, phase loss, over voltage, under voltage, motor stalling, over temperature, motor overload ENGLISH Technical data 2.2 Ratings 120VAC Doubler / 240VAC Models Type Power Mains Output Current Watts Loss[Hp/kW] Voltage(1) Iin ( 20V) Iin (240V) I n CLim max (2) ESV25 N0 SXB 0. / 0.25 120 V Single-phase (1/N/PE) .8 .4 .7 200 24 (90 … 2 V) ESV 7 N0 SXB 0.5 / 0. 7 OR 9.2 4. 2.4 200 2 ESV75 N0 SXB / 0.75 240 V Single-phase (2/PE) ( 70 … 2 4 V) . 8. 4.2 200 52 240VAC Models Type Power [Hp/kW] Mains Output Current Watts LossVoltage(1) Iin ~ (2/PE) Iin ~ ( /PE) I n CLim max (2) ESV25 N02SXB 0. / 0.25 240 V Single Phase (2/PE) .4 - .7 200 20 ESV 7 N02YXB 0.5 / 0. 7 240 V Single-phase (2/PE) OR 240 V Three-phase (3/PE) ( 70 … 2 4 V) 5. 2.9 2.4 200 27 ESV75 N02YXB / 0.75 8.8 5.0 4.2 200 4 ESV 2N02YXB .5 / . 2.0 .9 .0 200 4 ESV 52N02YXB 2 / .5 . 8. 7.0 200 75 ESV222N02YXB / 2.2 7. 0.8 9. 200 0 ESV 2N02TXB .5 / . 240 V Three-phase (3/PE) ( 70 V … 2 4 V) - .9 .0 200 4 ESV 52N02TXB 2 / .5 -8. 7.0 200 75 ESV222N02TXB ESV402N02TXB ESV552N02TXB / 2.2 5 / 4.0 7.5 / 5.5 - 0.8 9. 200 0 - 8. .5 200 54 -2 2 200 225 ESV752N02TXB 0 / 7.5 - 29 200 274 ( ) Frequency Range: 48 Hz … 2 Hz (2) Current Limit (CLim) is a percentage of the output current, I. CLim is the maximum setting for P 7 . n max ENGLISH Technical data 480VAC Models ESV 7 N04TXB ESV75 N04TXB ESV 2N04TXB ESV 52N04TXB ESV222N04TXB ESV402N04TXB ESV552N04TXB ESV752N04TXB Type Power [Hp/kW] Mains Output Current Watts Loss Voltage(1) Iin I n CLim max (2) 400V 480V 400V 480V 400V 480V 0.5 / 0. 7 400 V Three-phase (3/PE) ( 40 … 440 V) OR 480 V Three-phase (3/PE) ( 40 … 528 V) .7 .5 . . 75 200 2 / 0.75 2.9 2.5 2.4 2. 75 200 7 .5 / . 4.2 . .5 .0 75 200 48 2 / .5 4.7 4. 4.0 .5 75 200 57 / 2.2 . 5.4 5.5 4.8 75 2...

Este manual também é adequado para os modelos :
Fonte de alimentação e fonte de alimentação - Lenze V0100 (944.79 kb)
Fonte de alimentação e fonte de alimentação - Lenze V0100 (944.79 kb)
Fonte de alimentação e fonte de alimentação - Lenze SV01B (944.79 kb)
Fonte de alimentação e fonte de alimentação - Lenze SV01B (944.79 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias