Fasten in place between the 10mm nuts provided on the casting. Insert the two anti-short bushings into the holes on the right hand side in the upper brackets. 4. Install right side jacket panel to the upper and lower brackets with sheet metal screws provided. 5. Install the .” electrical connector required for the Carlin control or the Honeywell L7248A1000 through the hole in the front part of the right side jacket panel and tighten in place with the locknut provided. Install the Heyco bushing i
The chimney cap should be pyramid shaped on the top with a perfectly flat surface immediately above the chimney outlet. The hood should be attached by four (4) iron supports. The four iron supports should be equal in height to the width of the chimney opening. Four plates, flaring down, can be added to help insure that the wind will pass straight over the chimney outlet. Chimney Relining A tile lined masonry chimney serving an oil fired boiler should comply with applicable building codes such as
A safety control check for satisfactory performance must be performed. 1. High limit control - Remove the temperature control cover as needed and note temperature setting. With the burner running reduce the high limit setting until the burner shuts off. Return the high limit to its original setting. 2. To check the primary control and flame sensor shut off oil supply with hand valve while burner is running, fifteen seconds after flameout, the safety switch locks out, ignition stops and the oil v
562094 562094 562094 562094 562094 20 1 Wire Harness – Carlin Cont. 562092 562092 562092 562092 562092 21 1 Pipe Plug 1/4” Brass 712350 712350 712350 712350 712350 22 1 Bushing 3/4” x 1/4” 310410 310410 310410 310410 310410 23 1 Plug 3/4” 328004 328004 328004 328004 328004 24 1 Casting Assembly 705997 705998 705999 705600 705601 Solaia Residential Cast Iron Boiler Warranty First Year Limited Warranty for Solaia Residential Cast Iron Water Boilers Boyertown Furnace warrants that its residential c
d. The vent terminal shall not be less than 2 feet from an adjacent building. e. The vent terminal shall not be less than 7 feet above grade when located adjacent to public walkways. f. The vent terminal shall not be located so that flue gasses are directed to jeopardize people or overheat combustible structures, materials or enter buildings. g. All joints in the vent system are to be sealed with Permatex high temperature sealer or equivalent to prevent the leakage of products of combustion into
The indirect water heater, if used, should be wired in such a fashion that the heat to the building is temporarily interrupted when there is a demand for domestic water. Commercially available circulator prioritizing packages are available. Consult factory for their application. Swing Door Opening the Door 1. Turn off power to boiler. 2. Allow boiler to cool down. 3. Unplug the burner power cable at factory-supplied burner Molex plug electrical disconnect. 4. Lift the front jacket panel up and o
PO Box 100 BOYERTOWN, PA 19512 1-610-369-1450 1-10-06 Be Aware of Hazard Definitions Denotes presence of a hazard which, if ignored, will result in severe personal injury, death or property damage Denotes presence of a hazard which, if ignored could result in severe personal injury, death or substantial property damage. Denotes the presence of a hazard, which if ignored, could result in minor personal injury or property damage Intended to bring attention to information, but not related to person
When a boiler is located in an unconfined space in a building of conventional frame or masonry construction infiltration may provide adequate air for combustion and ventilation. If there is any doubt, install air supply provisions for combustion and ventilation in accordance with section 5.3, Air for Combustion and Ventilation, of the NFPA54 1988 code, it is recommend that you follow, the applicable provisions of the local building codes as well. When a boiler is installed in a confined space, i