Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Gas-Fired Products, Modelo 3102

Fabricante : Gas-Fired Products
Arquivo Tamanho: 368.47 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Be sure to secure shroud back into place before operation. 5. Connect the two wires to the two snapstat extension leads attached to the inner shroud. You may coil excess wire up inside the rear shroud. 6. Route the rheostat control switch and wire forward under the stove. (Fig. 12) Use the wire tie to secure the fan and rheostat wire harnesses together to the tubing under the heater. Pinch Grommet to Remove Snapstat Bracket Snapstat Module ST468 Fig. 10 Remove snaptstat and grommet from bracket. ST346a Snapstat Fig. 11 Attach snapstat to inner shroud. ST347a Rheostat Retaining Nut Control Knob Fig. 12 Attach rheostat to control panel. Valve may look different. Vermont Castings Jefferson Vent Free Gas Heater MOTOR SNAPSTAT ON/OFF RHEOSTAT WHT WHT BLKBLKBLK GRN BLK ST236 Fig. 13 Fan wiring diagram. Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below. The Jefferson Heater and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The Jefferson Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig. There must be a gas shutoff between the stove and the supply. In order to connect Natural Gas, use a fitting with 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 28,000 BTUs at a manifold pressure of 3.5” and minimum inlet supply for adjustment of 5.5” W.C. In order to connect Propane, use a fitting with 3/8” NPT nipple on the valve side and 1/2” propane gas supply line with an input of 28,000 BTUs at a manifold pressure of 11.0” and minimum inlet supply for adjustment of 11.0” W.C. Gas connection should be made in accordance with current National Fuel Gas Code, ANSI Z223.1. Since some municipalities have additional local codes, be sure to consult you local authority. Connect the gas supply and test for leaks. Use a 50/50 solution of liquid soap and water to test for leaks at gas fittings and joints. NEVER test with an open flame. Light the pilot according to the directions on page 14, before going to the next step. Install the Log Set 1. Remove the logs from their packaging, and inspect each piece for damage. DO NOT INSTALL DAMAGED LOGS. 2. Install the rear log 1 by centering it side to side on the sheet metal shelf at the back of the firebox. (Fig. 14) 3. Install the left 2 and right 3 middle logs by engaging holes on their bottoms with pins on the burner brackets. (Fig. 14) 4. Loosely sprinkle the lava rocks directly on top of the burner between the decorative grate and the middle logs. Do not place any e...

Este manual também é adequado para os modelos :
Eléctrico - 3105 (368.47 kb)
Eléctrico - 3095 (368.47 kb)
Eléctrico - 3096 (368.47 kb)
Eléctrico - 3095 (368.47 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias