4. Pilot flame does not touch the Thermocouple. (Figs. 29, 30) This can be caused by: A) Incorrect gas pressure, and/or B) other conditions that should be identified only by a qualified service technician. 5. Thermocouple is damaged. 6. Control Valve is damaged. Pilot lights but Main Burner does not. 1. Gas supply line shut-off valve is not fully open. 2. Foreign material is blocking Burner ports. 3. Main Burner orifice is clogged. 4. Thermostat or remote switch not activated on JUVS. 5. Bad Thermopile. 2. Fully open gas supply line shut-off valve. 3. Inspect and tighten securely. 4. A) Contact the local gas company. Inlet supply pressure should be 5” w.c.-8”w.c. for NG (5”w.c.-7”w.c. over 8000 ft. elevation) and 11”w.c.-12”w.c. for LP. Adjust as necessary. B)Call local gas service technician. 5. Call local gas service technician. 6. Call local gas service technician. Fig. 31 Correct LP Pilot Flame. Fig. 32 Correct NG Pilot Flame. 1. Fully open gas supply line shut-off valve. 2. Insptect and clear debris away from Burner ports. 3. Call local gas service technician. 4. Set thermostat to higher temperature or check remote switch. 5. Call local gas service technician. Main Burner shuts off and Pilot 1. Insufficient fresh air. flame goes out while in operation. 2. Incorrect inlet supply pressure. 1. Determine that adequate ventilation exists to provide sufficient fresh air. Open a window or provide additional ventilation. (See Fresh Air Requirements, Pages 67) 2. Contact the local gas company. Adjust inlet supply pressure to specification: NG; 5”w.c.-8”w.c. (5”w.c.-7”w.c. at elevations over 8000 ft.) LP; 11”w.c.-12”w.c. Vermont Castings Jefferson Vent Free Gas Heater WARNING If you smell gas: • Shut off gas supply • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. ODOR DURING OPERATION Neither natural gas nor propane gas give off an odor when burned. The nature of a vent free combustion system, however, is such that odors may occasionally be produced during heater operation when impurities exist in the immediate area. Cleaning solutions, paint, solvents, cigarette smoke, candles, adhesives, new carpet or textiles, etc., all can create fumes. These fumes may mix with combustion air and can create odor. Such odors will disappear over time, however, the condition can be alleviated by opening a window or otherwise providing additional ventilation to the area. R Models Only OFF ON ThermopileBlack Black TP/TH TP TH On/Off Switch Wiring ST124b Thermostat (Optional) ThermopileBlack Black TP/TH TP TH Optional Thermostat Wiring G ST124c Vermont Castings Jefferson Vent Free Gas Heater 1 a b c d e PILOTON OFF PILOTADJ LO HI TPTH TH TP 2 3 5 6 9 87a,b4 15a 10 13 14 16a,b 17 11 12 18 19a,b c,d 15b 20 HIOFFPILOT LO 16c,d 21 15c 15d 3447 The ...

Este manual também é adequado para os modelos :
Eléctrico - 3105 (368.47 kb)
Eléctrico - 3095 (368.47 kb)
Eléctrico - 3096 (368.47 kb)
Eléctrico - 3095 (368.47 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias