Log:
Assessments - , GPA: ( )

Instruções de Operação Desa, Modelo (V)KC42P SERIES

Fabricante : Desa
Arquivo Tamanho: 2.05 mb
Arquivo Nome :

Língua de Ensino: en

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere

Facilidade de uso


Open lower louver door panel by gently pulling forward. 2. Route flexible gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes on side of fireplace. 3. Attach flexible gas line from gas supply to control valve (see Figure 32). 4. Check all gas connections for leaks. See Checking Gas Connections. To Gas Supply (Natural) To External Regulator (Propane/LP) Flexible Gas Line Do NOT Kink Equipment Shutoff Valve Control Valve Figure 32 - Connecting Flexible Gas Line to Millivolt Valve CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections , internal and external to unit, for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LPsupply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 116239-01B 116239-01B 20 Figure 33 - Equipment Shutoff Valve Open Closed Equipment Shutoff Valve Figure 35 - Checking Gas Joints for Natural Gas Fireplace Figure 34 - Checking Gas Joints for Propane/LP Gas Fireplace Propane/LP Supply Tank Gas Valve Equipment Shutoff Valve Gas Meter Gas Valve Equipment Shutoff Valve FIREPLACE INSTALLATION Continued FIREPLACE INSTALLATION Checking Gas Connections (Cont.) Installing Optional Wall Mount Switch - GWMS2 Figure 36 - Connecting Wall Swith to Control Valve To Wall Switch Accessory 5. Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 33). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air. 3. Check al l joints from propane/LP supply tank or ga s meter to e quipm ent shutoff valve (see Fi gure 34, for propane /LP or Figure 35, for natura l gas). Apply noncorrosive leak detection fluid t o all joints. Bubbles for ming sh ow a leak. Correct all leaks at once. Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 33). 2. Op en propane/LP supply tank valve for propane/LP fi re plac e or main ga s v alve lo cated on or near gas meter fo r natu ra l gas fireplace. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to gas valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Light fireplace (see Operating Fireplace, page 23). Check all other internal joints for leaks. 6. Turn off fireplace (see To Turn Off Gas to Appliance, page 24). INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2 1. Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 36. If wires are not connected as shown the switch will not work. 2. Route the 25 ft. wire through openings provided on the sides of the burner system to a convenient location to mount your switch. 3. Connect one bare wire end to each of the terminals of the GWMS2 wall switch. 4. Install the wall switch and cover in the wall. FIREPLACE INSTALLATION Installing Optional Wireless Hand-Held Remote Control - GHRCB and GHRCTB Series Removing/Replacing Glass Door 21 FIREPLACE INSTALLATION Continued INSTALLING OPTIONAL WIRELESS HANDHELD REMOTE CONTROL - GHRCB AND GHRCTB SERIES NOTICE: Use only alkaline batteries (not included). Installing Remote Receiver 1. Open bottom louver and locate the switch bracket on the left. 2. Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver. 3. Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip (see Figure 37). 4. Attach the terminal wires to the battery. 5. Connect wires from receiver to TH and TPTH to control valve (see Figure 38). 6. Replace the swit...

Este manual também é adequado para os modelos :
Lareiras - (V)KC42N Series (2.05 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias