Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação HP, Modelo HP Integrity NonStop Release and Migration

Fabricante : HP
Arquivo Tamanho: 34.84 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


Page 13 of 21
Cause: A filter registration failed on subnet name for the ip-addr.
This event could be due to an improperly configured NonStop TCP/IPv6
subsystem or an internal NonStop TCP/IPv6 subsystem problem.
Effect: The NonStop TCP/IPv6 subsystem will attempt to re-register
the filter. If the filter registration is for a Subnet filter and the
problem continues, the Subnet becomes inaccessible. If the
registration is for a Port filter and the problem continues, filter
registration will fail.
Recovery: Determine the type and the cause of the failed registration
from the err-code value and take appropriate action.
18 (Critical Event)
if-name: Filter Register For IP Address ip-addr Failed, Timed Out.
Cause: A filter Register timeout occurred on subnet if-name for
ip-addr.
Effect: None.
Recovery: The NonStop TCP/IPv6 subsystem will try the filter
registration at a later time. No operator intervention is required.
19 (Critical Event)
name: Filter Register For IP Address ip-addr Failed,
Already In Use, Filter Type = type, Local port = l-port,
Foreign port = f-port.
Cause: A filter register is already in use on subnet name for
ip-addr. This event could be due to an improperly configured NonStop
TCP/IPv6 subsystem or an internal subsystem problem.
Effect: No retry will be done by the NonStop TCP/IPv6 subsystem.
The application will receive a proper error code.
Recovery: Determine the type and the cause of the failed registration
from the error code value and take the appropriate action.
20 (Critical Event)
name: Filter De-register For IP Address ip-addr Failed,
Error = err-code, Filter Type = type Local Port = port.
Cause: A filter de-registration failed on subnet x for the IP
address. This event could be due to an improperly configured NonStop
TCP/IPv6 subsystem or an internal NonStop TCP/IPv6 subsystem problem.
Effect: None.
Recovery: Determine the type and cause of the failed registration
from the err-code value and take the appropriate action.
21 (Critical Event)
module: No ARP cache for Route route-name: IP Address ip-addr.
Cause: The NonStop TCP/IPv6 subsystem failed to resolve an IP address
into an Ethernet address.
Effect: All the communication attempts will use ip-addr to resolve
a link-level route, and the ARP cache will fail.
Recovery: Examine the routing tables in the processor in which this
event is reported to ensure that:
-The routing tables are set up properly,


...


Escreva a sua própria avaliação do dispositivo