Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Yamaha, Modelo DME24N

Fabricante : Yamaha
Arquivo Tamanho: 6.96 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


Remote (232C): MIDI data will be received via the [REMOTE] connector using an RS-232C connection. Remote (422): MIDI data will be received via the [REMOTE] connector using an RS-422 connection. MIDI: The MIDI connector is the currently active MIDI port. USB-1, USB-2: The corresponding USB port is selected for MIDI input. Slot1 [Slot1 ~ Slot4 (DME64N)]: A card installed in the corresponding I/O slot is currently selected for MIDI input. Edit using the “List Parameters” editing procedure described on page 38. NOTE When the DME64N/24N is functioning as the device group master and is connected to a computer running the DME Designer application via USB, the MIDI port being used by the DME Designer will not be available. DME64N/DME24N Owner’s Manual 49 Panel Utility Displays 2 Protocol (MIDI Protocol Setup) Word Clock Setup (WCLK) Page Displays/sets the protocol to be used for communication with devices connected via MIDI. The available settings Shows the status of incoming word clock signals, and are: MIDI, DAW(Type1), and DAW(Type2). allows setup of the DME64N/24N master word clock. MIDI: Use this setting when any MIDI device other than a general-purpose ProTools controller (HUI protocol) or general-purpose Logic or Cubase controller (Mackie control protocol) is to be connected. DAW (Type1): Use this setting when a general- purpose ProTools controller (HUI protocol) is to be connected. DAW (Type2): Use this setting when a general- purpose Logic or Cubase controller (Mackie control protocol) is to be connected. Edit using the “List Parameters” editing procedure described on page 38. Refer to the DAW controller owner’s manual as well as the DME Designer manual for setup details. NOTE This page will not be displayed on the ICP1. 1 2 3 4 Master Clock Selection Procedure 1. Use the cursor [ E ], [ • ], [ • ], [ F ], buttons to select one of the square blocks NOTE representing the available master clock sources. “DAW” stands for “Digital Audio Workstation.” ProTools, Logic, and Cubase are DAW applications, and this parameter provides direct compatibility with a number of physical controls surfaces that are available for use with these DAW software packages. The following parameters are available when the Protocol parameter is set to MIDI. 3 CH Specifies the device’s MIDI transmit and receive channel: 1 ~ 16. Edit using the “List Parameters” editing procedure described on page 38. 4 Program Change Turns transmission and reception, the omni mode, and echo ON or OFF for MIDI program change messages. Move the cursor to the required parameter, then press the [ENTER] button to alternately turn ON and OFF. 5 Control Change Turns transmission and reception, the omni mode, and echo ON or OFF for MIDI control change messages. Move the cursor to the required parameter, then press the [ENTER] button to alternately turn ON and OFF. 6 Parameter Change Turns transmission and reception, and echo ON or OFF for MIDI parameter change messages. Move the cursor to the required parameter, then press the [ENTER] button to alternately turn ON and OFF. 2. Press the [ENTER] button to select the master clock. 1 Fs The current sampling frequency of the master word clock. The value shown here is determined by the system’s master word clock signal. To select the word clock to be used as the master, move the cursor to the appropriate word clock indication in this display – the [WORD CLOCK IN] clock, the cascade clock, or a slot clock, for example – and press the [ENTER] button. 2 Int Sets the frequency of the internal word clock – 44.1 kHz, 48 kHz, 88.2 kHz, or 96 kHz. 3 WCIN Shows the status of the word clock signal at the [WORD CLOCK IN] connector. 4 Cascade Shows the status of the word clock signal at the [CASCADE IN] and [CASCADE OUT] connectors. Panel Operation and Displays 50 DME64N/DME24N Owner’s Manual Utility Displays 5 SLOT1~4 GPI Setup (GPI) Page Shows the status of the word clock signal input via I/O cards installed in the I/O slots. Input calibration parameters for the [GPI] connector. The Status Icons A word clock signal is present, and this signal can be selected as the DME64N/24N word clock. No word clock signal (cannot be selected as the master clock). A word clock signal is present, but is not in sync with the master word clock. Currently selected as the DME64N/24N word clock. Currently selected as the DME64N/24N word clock, but the clock signal is not useable. Inactive slot channel, or no I/O card is present in the slot. NOTE This page will not appear on the ICP1 display. 1234 Slot Information (Slot) Page Displays the name of the card installed in an I/O card slot. Some cards can also be reset via this page. 213 1 Reset Resets GPI calibration. To reset the calibration, use the [ E ] [ . ] [ . ] [ F ] buttons to select ALL to reset all inputs, or select an individual input from 1 to 16 to be reset, then press the [ENTER] button. 2 MAX Sets the maximum calibration value. To set the MAX value, use the [ E ] [ . ] [ . ] [ F ] button...

Este manual também é adequado para os modelos :
Instrumentos musicais - DME64N (6.96 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias