Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Yamaha, Modelo DME24N

Fabricante : Yamaha
Arquivo Tamanho: 50 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


NOTE Each design windows within the Designer window can be switched using the [Window] menu in the Designer window. [About] Menu • [About DME Designer] Displays information about this application. DME Designer Owner’s Manual 69 Chapter 3 Main Panel Window Chapter 3 Main Panel Window Allows management of DME files. Project files can be managed on the DME, eliminating the need to manage them on the computer. Project files can be managed on a DME unit without the need for a computer. Since project files are necessary to allow synchronization of DME and SP2060 units, we recommend that you save your project files to the DME unit for enhanced reliability. Click [DME File Storage] in the [File] menu to display the “DME File Storage” dialog. NOTE Does not apply to SP2060 units NOTE If the file name is to include Japanese characters, select “Japanese” via the “Language” dialog box (page 182). If the file name is to include non-English Latin characters (Latin-1), select “English/German/French/Spanish”. Inappropriate combinations of file names and Language settings can make files unreadable in some cases. Names and Functions • Zone List Select the desired zone and device group and DME from the list. • File List A list of the files stored on the selected DME. • [Send] Button Transfers selected files from the computer to the DME. • [Receive] Button Transfers selected files from the DME to the computer. • [Delete] Button Deletes selected files from the DME. • [Close] Button Closes the dialog box. NOTE Synchronization may become impossible if the [Remaining Memory] value (the amount of remaining DME memory) becomes too small. If this occurs, delete unwanted scenes or files to increase the amount of available memory. 70 DME Designer Owner’s Manual Chapter 3 Main Panel Window Chapter 3 Main Panel Window The screen image appearing when the DME64N/24N starts up can be replaced with a graphic file of your choice in the following way. This function allows you to display a desired startup screen-for example, one that includes your facility's name and logo. • Preparing the graphic data Create the desired graphic data at a size of 160 x 48 dots in black-and-white bitmap format (extension .bmp) and save it as a file with the name “opening.bmp.” • Replacing the graphic data Transmit the graphic file (“opening.bmp”) to the DME unit using the DME File Storage function from the DME Designer. This image will be displayed at the startup screen from the next time when the DME starts up. NOTE • To restore the default startup screen, create a dummy file and change the name to “blank.bmp.” and storage it in the same way as above. The default startup screen will be displayed from the next time when the DME starts up. • The file transmitted to the DME unit using the DME File Storage function will be automatically erased after completing the internal configuration. This means the file is not stored on the DME unit. • Compatible graphic files are limited to black-and-white bitmap format at a size of 160 x 48. Other graphic files cannot be displayed. • The “Copyright” indication at the bottom of the screen cannot be erased. • Only the DME64N/24N is compatible with this function. The ICP1 is incompatible. DME Designer Owner’s Manual 71 Chapter 3 Main Panel Window Chapter 3 Main Panel Window s When you click the [Preferences] command on the [File] menu in the Main Panel window, the “Preferences” dialog box is displayed. Here you can make environmental settings for using DME Designer. Names and Functions • [Application] Tab Here you can set the general usage environment. On Startup Selects the action when the application starts up or a user logs on. • [Load the last file opened] Opens the last opened file. If the file cannot be found because it was moved, deleted, or its name was changed, a new project will be opened. • [Create an empty file] Opens a new project. • [Load File & Synchronization] Opens the last opened file and synchronizes with the DME or SP2060 unit. Contents Folder Specifies the folder in which common files that are not project dependent are saved. Click the [Browse] button to locate and specify the folder. The files listed below are saved in the specified folder. • User module template files • All types of library files • Wave files • Graphic files NOTE If the folder is changed, files that were stored in the previous folder will not be automatically moved or copied to the new folder. To carry the files over to the new folder, export the files as “DME Designer All” before changing the folder, then re- import the files after the new folder has been specified. 72 DME Designer Owner’s Manual Chapter 3 Main Panel Window Chapter 3 Main Panel Window Set up the automatic file save feature. This setting has no effect when the file being worked on has not previously been saved, or the computer is online. • [Enable] Auto save of project files being worked on will occur when checked. The file will be overwritten, but the Undo history will not ...

Este manual também é adequado para os modelos :
Instrumentos musicais - DME64N (50 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias