Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Manitowoc Ice, Modelo Flake QF0400

Fabricante : Manitowoc Ice
Arquivo Tamanho: 2.34 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


(121.9 cm.) 55.0 in. (139.7 cm.) B1400 60 in. (152.4 cm.) 55.0 in. (139.7 cm.) The bin drain is exactly in the center of the bin. Part Number 000002688 Section 2 Installation Instructions Location of Ice Machine The location selected for the ice machine must meet the following criteria. If any of these criteria are not met, select another location. • The location must be free of airborne and other contaminants. • The air temperature must be at least 45°F (7°C), but must not exceed 110°F (43.4°C). • The water temperature must be at least 45°F (7°C), but must not exceed 90°F (32.2°C). • The location must not be near heat-generating equipment or in direct sunlight. • The location must be capable of supporting the weight of the ice machine and a full bin of ice. • The location must allow enough clearance for water, drain and electrical connections in the rear of the ice machine. • The location must not obstruct airflow through or around the ice machine. QF400 airflow is in and out of the front of the ice machine. Refer to below for clearance requirements. Ice Machine Head Section Clearance Requirements QF400 Self-Contained Air-Cooled Self-Contained Water-Cooled Top/Sides 5” (12.7 mm) NA Back 5” (12.7 mm) NA Ice Machine Heat of Rejection Series Condensing Unit Heat of Rejection* QF400 4000 QC700 7800 QF800 7800 QF2300/RFC2385 21000 *B.T.U. / Hour Ice machines, like other refrigeration equipment, reject heat through the condenser. It is helpful to know the amount of heat rejected by the ice machine when sizing the air conditioning equipment where self-contained air- cooled ice machines are installed. QF2300 ice machines add an insignificant amount of load to a conditioned space. Location of Remote Condensing Unit The location selected for the Remote Condensing Unit must meet the following criteria. If any of these criteria are not met, select another location. • The air temperature must be at least -20°F (-28.9°C) but must not exceed 120°F (49°C). • The location must not allow exhaust fan heat and/or grease to enter the condenser. • The location must not obstruct airflow through or around the condensing unit. Refer to the chart below for clearance requirements. CONDENSING UNIT CLEARANCE REQUIREMENTS QC700/QF800 Self-Contained Air-Cooled Self-Contained Water-Cooled Top/Sides 8” (20.3 mm) 5” (12.7 mm) Back 5” (12.7 mm) 5” (12.7 mm) Ice Machine Condensing Unit Top/Sides There is no minimum clearance required, although 6” (12.7 cm) is recommended for efficient operation and servicing only. Front/Back 4’ (1.2 M) QF2300 Self-Contained Air-Cooled Remote Air-Cooled Top/Sides NA 5” (12.7 mm) Back NA 5” (12.7 mm) ! Caution The ice machine head section must be protected if it will be subjected to temperatures below 32°F (0°C). Failure caused by exposure to freezing temperatures is not covered by the warranty. See “Removal from Service/Winterization”. Part Number 000002688 Installation Instructions Section 2 Leveling the Ice Storage Bin 1. Screw the leveling legs onto the bottom of the bin. 2. Screw the foot of each leg in as far as possible. ! Caution The legs must be screwed in tightly to prevent them from bending. 3. Move the bin into its final position. 4. Level the bin to assure that the bin door closes and seals properly. Use a level on top of the bin. Turn each foot as necessary to level the bin. 5. Inspect bin gasket prior to ice machine installation. (Manitowoc bins come with closed cell foam gasket installed along the top surface of the bin.) 6. Install ice machine on bin. NOTE: An optional caster assembly is available for use in place of the legs. Installation instructions are supplied with the casters. SV1606 THREAD LEVELING LEG INTO BASE OF CABINET THREAD ‘FOOT’ IN AS FAR AS POSSIBLE Leveling Leg and Foot Condenser Air Baffle (QC700/QF800 Air-Cooled Ice Machines Only) The air-cooled baffle prevents condenser air from recirculating. To install: 1. Remove the back panel screws next to the condenser. 2. Align the mounting holes in the air baffle with the screw holes and reinstall the screws. AIR BAFFLE SCREWS SV1607 Air Baffle Part Number 000002688 Section 2 Installation Instructions Electrical Service ! Warning All wiring must conform to local, state and national codes. VOLTAGE The maximum allowable voltage variation is ±10% of the rated voltage on the ice machine model/serial number plate at start-up (when the electrical load is highest). GROUND FAULT INTERRUPTER CIRCUIT (GFIC) Ground Fault Circuit Interrupter protection is a system that shuts down the electric circuit (opens it) when it senses an unexpected loss of power, presumably to ground. Manitowoc Ice, Inc. does not recommend the use of a GFCI/GFI circuit protection with our equipment. If code requires the use of a GFCI/GFI then you must follow the local code. The circuit must be dedicated (accept QuietQubes), sized properly and there must be a panel GFCI/GFI breaker. We do not recommend GFCI/ GFI outlets as they are known for more intermittent nuisance tr...

Este manual também é adequado para os modelos :
Outros aparelhos de cozinha - Chiplet QC0700 (2.34 mb)
Outros aparelhos de cozinha - Flake QF0800 (2.34 mb)
Outros aparelhos de cozinha - Flake QF2300 (2.34 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias