These release notes describe the modifications and known issues for Patch 22. The application of this
patch is intended for HP 3PAR InForm OS 2.3.1.298. Only an authorized HP Service provider should
perform this maintenance procedure.
1.1 Supported platforms
The HP 3PAR Configuration Matrix for InForm OS 2.3.1 contains information about supported hardware
and software platforms. For additional information, go to the Single Point of Connectivity Knowledge
for HP Storage Products (SPOCK) Web site at http://spock.corp.hp.com/index.aspx.
1.2 Verifying the patch installation
The installation of Patch 22 can be verified from an Interactive CLI session. Issue the CLI command
showversion -a -b to verify that Patch 22 is listed.
cli% showversion -a -b
Release version 2.3.1.298
Patches: P22
Component Name Version
CLI Server 2.3.1.298
CLI Client 2.3.1.298
System Manager 2.3.1.298
...
NOTE:
This patch is not revertible after installation.
1.3 Components
Component
Version
HMRSK0002TBAT07K 2TB Drive Firmware
3P01
SMSKP0001TBAT07K 1TB Drive Firmware
3P01
SMSKP0002TBAT07K 2TB Drive Firmware
3P01
DC2 Firmware
2.61
DC3 Firmware
08
DC4 Firmware
2.61
1.4 Modifications to the InForm OS
The following items have been addressed in this release.
Bug ID
Item
Description
37139
DC2 and DC4 drive recovery Drive chassis error recovery improvements have been made to the DC2 (P/N:
improvements
647978-001) and DC4 (P/N: 640843-001) drive chassis by adding a LIP
(Loop Initialization Primitive) Reset to the case where the current loop (good
loop) is at the third bucket counter error and the other loop is down.
42183
Cage firmware indicates a
Improvement for a condition when there is heavy I/O and a hard cage reset,
drive has not spun up
some drive LEDs may incorrectly display amber indicating a drive has failed
to spin up when the drive is in normal condition and has spun up and I/O
is running as expected.
56585
Cage becomes inaccessible
Found error in serial port where characters were looped back to the serial
after reset
port which sometimes could cause a timeout and result in a cage reset and
becomes inaccessible. The fix prevents any characters from returning to the