|
Facilidade de uso
10 Fig. 10a Fig. 10b 1 4 5 3 6 1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in back of top half of FLUSH VALVE CAP (3). Fig. 12a. 2. Rotate CAP (3) to the right and pull off. Fig. 12b. 3. Turn CAP (3) over and remove the two SCREWS (4). Remove the BATTERY COVER (5) to expose the battery (6). Remove old BATTERY (6). Fig. 12c. 4. Install the new BATTERY (7) making sure the + & - are facing up towards the open end of the cover. Fig. 12d. 5. Replace the BATTERY COVER (5), reverse the above steps to assembly flush valve. HOW TO CHANGE THE BATTERY; Fig. 12 1 7 5 4 6 6 Fig. 12a Fig. 12c Fig. 12d Fig. 12 OLD BATTERY OUT NEW BATTERY IN 2 3 7 M968699 Rev. 1.14 Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required follow the steps below. 1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in back of top half of FLUSH VALVE (3). Fig. 13a. 2. Rotate CAP (3) to the right and pull off. Fig. 13b. 3. Turn CAP (3) over and disconnect GREY SENSOR WIRE (4) from BATTERY COVER (5). 4. Keeping hands away from the front of the sensor, reconnect the GREY SENSOR WIRE (4) and quickly place the CAP (3) on the valve. Do not secure the CAP (3) at this time. Note: You have 5 seconds after connecting cable to enter program code. 5. While the SENSOR CONTROL LED (6) is blinking slowly, place your hand 1 to 2 in. (30-50mm.) in front of the sensor. Fig. 14a. 6. When the LED (6) stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, 1-1/2" to 31", 38 to 787mm ) and hold in place until the LED (6) begins to blink again. Fig. 14b. Note: Detection Zone is 1-1/2" to 31", 38 to 787mm from sensor. 7. Once the SENSOR CONTROL LED (6) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. 8. Replace and secure CAP (3) onto valve. 9. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor; unit will flush in approximately 3 seconds. HOW TO SET DETECTION RANGE (If Required) ; Fig. 13 & 14 6 6 Fig. 13b Fig. 13 Fig. 14 Fig. 14a Fig. 14b VIEW “A” VIEW “A” 10 DETECTION ZONE 38mm TO 787mm (1-1/2 TO 31) 1 Fig. 13c Fig. 13a 2 4 5 3 1" - 2" (30mm - 50mm BLINKING LED BLINKING LED 3 6 IS S T OP V A L VE OPEN? L OOK FOR REPEA TED DOUBLE FLA SH ON SENSOR YES INS T ALL NEW B A TTER Y TR Y MANU AL V A L VE B U TT ON; WILL THE UNIT FLUSH? NO REPLA CE PIS T ON KIT INS T ALL NEW B A TTER Y SEE S TEP 1 0, pag e 6 in manual NO REPLA CE SENSOR NO YES NO NO YES YES OPEN V A L VE UNIT WILL ONLY FLUSH MANUALLYLOOK FOR REPEATEDDOUBLE FLASH ON SENSORRETRY AUTOMATIC FLUSH. DOES THE UNIT FLUSH? RETRY AUTOMATIC FLUSH. TEST SENSOR. DISCONNECTGRAY FLAT WIRE FROM BATTERYCOVER AND RE-CONNECT. SENSORSHOULD FLASH FOR 5 SECONDS.DOES IT FLASH? TEST SENSOR. DISCONNECTGRAY FLAT WIRE FROM BATTERYCOVER AND RE-CONNECT. SENSORSHOULD FLASH FOR 5 SECONDS.DOES IT FLASH? CLOS...
Este manual também é adequado para os modelos :Canalização - SELECTRONIC 6065.121 (1.01 mb)
Canalização - SELECTRONIC 6065.122 (1.01 mb)
Canalização - SELECTRONIC 6065.122 (1.01 mb)
Canalização - SELECTRONIC 6065.121 (1.01 mb)