|
Facilidade de uso
1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in back of top half of FLUSH VALVE (3). Fig. 13a. 2. Rotate CAP (3) to the right and pull off. Fig. 13b. 3. Turn CAP (3) over and disconnect GREY SENSOR WIRE (4) from BATTERY COVER (5). 4. Keeping hands away from the front of the sensor, reconnect the GREY SENSOR WIRE (4) and quickly place the CAP (3) on the valve. Do not secure the CAP (3) at this time. Note: You have 5 seconds after connecting cable to enter program code. 5. While the SENSOR CONTROL LED (6) is blinking slowly, place your hand 1 to 2 in. (30-50mm.) in front of the sensor. Fig. 14a. 6. When the LED (6) stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, 1-1/2" to 31", 38 to 787mm ) and hold in place until the LED (6) begins to blink again. Fig. 14b. Note: Detection Zone is 1-1/2" to 31", 38 to 787mm from sensor. 7. Once the SENSOR CONTROL LED (6) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. 8. Replace and secure CAP (3) onto valve. 9. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor; unit will flush in approximately 3 seconds. HOW TO SET DETECTION RANGE (If Required) ; Fig. 13 & 14 6 6 Fig. 13b Fig. 13 Fig. 14 Fig. 14a Fig. 14b VIEW “A” VIEW “A” 10 DETECTION ZONE 38mm TO 787mm (1-1/2 TO 31) 1 Fig. 13c Fig. 13a 2 4 5 3 1" - 2" (30mm - 50mm BLINKING LED BLINKING LED 3 6 IS S T OP V A L VE OPEN? L OOK FOR REPEA TED DOUBLE FLA SH ON SENSOR YES INS T ALL NEW B A TTER Y TR Y MANU AL V A L VE B U TT ON; WILL THE UNIT FLUSH? NO REPLA CE PIS T ON KIT INS T ALL NEW B A TTER Y SEE S TEP 1 0, pag e 6 in manual NO REPLA CE SENSOR NO YES NO NO YES YES OPEN V A L VE UNIT WILL ONLY FLUSH MANUALLYLOOK FOR REPEATEDDOUBLE FLASH ON SENSORRETRY AUTOMATIC FLUSH. DOES THE UNIT FLUSH? RETRY AUTOMATIC FLUSH. TEST SENSOR. DISCONNECTGRAY FLAT WIRE FROM BATTERYCOVER AND RE-CONNECT. SENSORSHOULD FLASH FOR 5 SECONDS.DOES IT FLASH? TEST SENSOR. DISCONNECTGRAY FLAT WIRE FROM BATTERYCOVER AND RE-CONNECT. SENSORSHOULD FLASH FOR 5 SECONDS.DOES IT FLASH? CLOSE STOP VALVE, REPLACE SOLENOID KIT. RE-ASSEMBLE & INSTALL UNIT. OPEN STOP VALVE. BATTERY LOW; REPLACE BATTERYSEE STEP 10, page 6in manual NONOYES DOES THE SENSOR FLASHFOR THE FIRST 5 SECONDS? NO REPLACE SOLENOID KIT RETRY AUTOMATIC FLUSH; WAS IT SUCCESSFUL? YES 1. COVER SENSOR FOR 10 SECONDS2. UNCOVER SENSOR FOR 10 SECONDS. REPLACE BATTERYSEE STEP 10, page 6in manual MANUAL VALVEOBSTRUCTED. CLOSE STOP VALVEAND SERVICERETRY AUTO FLUSH NO UNIT IS CONTINUOUSLY FLUSHINGPUSH MANUAL FLUSHBUTTON; DOES IT RETURN? LOOK FOR REPEATEDDOUBLE FLASH ON SENSORNONOYES NO 1. COVER SENSOR FOR 10 SECONDS2. UNCOVER SENSOR FOR 10 SECONDS. DOES THE UNIT STOP FLUSHING? YES INSTALL NEW BATTERYSEE STEP 10, page 6in manual YES 1. CLOSE STOP VALVE, 2. REPLACE S...
Este manual também é adequado para os modelos :Canalização - SELECTRONIC 6065.121 (1.01 mb)
Canalização - SELECTRONIC 6065.122 (1.01 mb)
Canalização - SELECTRONIC 6065.122 (1.01 mb)
Canalização - SELECTRONIC 6065.121 (1.01 mb)