Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Wayne, Modelo DSP60

Fabricante : Wayne
Arquivo Tamanho: 274.8 kb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Faulty float switch 1. Install check valve 2. Replace float switch 3. Check valve not installed or leaking 3. Remove and examine check valve for proper installation and free 4. Discharge head is less than operation manufacturer's minimum 4. Recheck all sizing calculations to determine proper pump size Pump shuts off and turns 1. Excessive water temperature 1. Pump should not be used for water above 120° on independently of 2. Defective switch or entangled switch 2. Replace or reposition pump switch (trips thermal is causing pump to run dry overload protection) Pump may start unexpectedly. Disconnect power supply before ser vic ing 3. Low line voltage 3. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company Pump operates noisily or vibrates excessively 1. Worn bearings 2. Debris in impeller cavity or broken 1. Return for service or replace 2. Remove housing, clean impeller and/or replace broken impeller 3. Piping attachments to building 3. Replace portion of discharge pipe with flexible connector structure too rigid or too loose Pump will not shut off 1. Defective float switch 1. Replace float switch 2. Float switch movement restricted 2. Reposition pump or clean basin as required to provide adequate clearance for float 3. Restricted discharge (obstruction in 3. Remove pump and clean pump & piping piping) 4. Recheck all sizing calculation to determine proper pump size 4. Excessive inflow or pump not properly sized for application Pump operates but delivers little or no water 1. Low line voltage 1. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company 2. Debris caught in impeller or discharge 2. Remove, clean and check for tightness 3. Worn or defective pump parts or 3. Replace worn parts or entire pump. Clean parts if required plugged impeller 4. Pump running backwards 4. Check rotation. (CCW from bottom) Return if CW 5. Pump not properly sized for application 5. Recheck all sizing calculations to determine proper pump size 6. Check valve stuck closed or installed 6. Remove and examine check valve for proper installation and free backwards operation 7. Shut off valve closed 7. Open valve For Replacement Parts, call 1-800-237-0987 3 6781 2 Ref No. Description Part. No. Qty. 1 1/4” NPT Plug 16356-004 1 Please provide following 2 Power Cord-10 ft. 31035-001 1 information: 3 Handle 23124 1 -Model number -Serial number (if any) 4 4 Motor Housing 41026-001 1 -Part description and number as 5 O-ring 19040-001 1 shown in parts list 6 Motor Assembly* 63004-001 1 7 Impeller 41032-001 1 Address parts correspondence to: 5 Wayne Water Systems 8 Volute 41028-001 1 100 Production Drive 9 7/16”-14 x 1-1/4” Hex Head Screw ** 3 Harrison, OH 45030 U.S.A. 10 5/16”-18 x 3/4” Hex Head Screw ** 3 11 10-24 x 1/2” Round Head Machine Screw ** 2 *Includes Motor, Seal Plate, Shaft Seal, and O-ring **Standard Hardware Item 4 Pompe Pour EauxUsees Veuillez lire et conserver ces instructions. Lire attentivement avant d'assembler, d'installer, de faire fonctionner ou de faire l'entretien du produit decrit. Observer toute l'information pour se proteger soi-meme et les autres. Le non-respect de ces instructions pourrait mener a des blessures personnes et/ou des dommages ! Conservez ces instructions a titre de reference. Instructions d’Utilisation et Manuel de Pieces de Rechange Modeles DSP60 et DSP75 Description Une pompe d'egout est prevue pour les stations de relevage des eaux usees. Elle convient pour pomper les egouts, les effluents, les eaux usees, les eaux de fond, et autres liquides non-explosifs, non-corrosifs avec solides de jusqu'a 2 pouces (5cm). Un dispositif de controle de moteur acceptable doit etre fourni au moment de l'installation Deballage Inspecter cet appareil avant de l'utiliser. A l'occasion, les produits sont endommages durant l'expedition. Si la pompe ou les composants sont endommages, retourner l'appareil a l'emplacement d'achat pour remplacement. Le non-respect de ces instructions pourrait mener a des blessures graves ou a la mort. Directives De Securite Ce manuel contient de l’information tres importante qui est fournie pour la SECURITEet pour EVITER LES PROBLEMESD’EQUIPEMENT. Rechercher les symboles suivants pour cette information. Danger indique une situation hasardeuse imminente qui resultera en perte de vie ou blessures graves. Avertis sement indique une situation hasardeuse potentielle qui peut resulter en perte de vie ou blessures graves. Attention indique une situation hasardeuse potentielle qui peut resulter en blessures. Avis indique l’information importante pour eviter le dommage de l’equipement. Generalites Sur La Securite 1. Se familiariser avec l’application, les limites et les hasards potentiels de la pompe. Ne pas utiliser pour le pompage des liquides inflammables ou explosifs tels que l’essence, l’huile a chauffage, le kerosene, etc. Ne pas utilise...

Este manual também é adequado para os modelos :
Canalização - 330600-001 (274.8 kb)
Canalização - DSP75 (274.8 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias