Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Wayne, Modelo DSP75

Fabricante : Wayne
Arquivo Tamanho: 274.8 kb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Operating Instructions and Parts Manual Models DSP60 and DSP75 Description A sewage pump is intended for use in domestic sewage lift stations. It is suitable for pumping sewage, effluent, wastewater, groundwater, and other nonexplosive, noncorrosive liquids with up to 2 inch solids. An acceptable motor control device must be provided at time of installation. Unpacking Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement. Failure to do so could result in serious injury or death. Safety Guidelines This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols. Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. Notice indicates important information, that if not followed, may cause damage to equipment. General Safety Information 1. Know the pump application, limitations, and potential hazards. Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in flammable and/or explosive atmospheres. Use pump only with liquids compatible with pump component materials. Failure to follow this warning can result in personal injury and/or property damage. 2. Make certain that the power source (electric motor) conforms to the requirements of the equipment. Disconnect power before servicing. If the power dis con nect is out of sight, lock in the open po si tion and tag it to prevent unexpected application of power. Failure to do so could result in fatal electrical shock! 3. Release all pressure within the system before servicing any component. 4. Drain all liquids from the system before servicing. 5. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage. 6. Check hoses for weak and worn condition before each use, making certain that all connections are secure. 7. Periodically inspect the pump and system components. Perform routine maintenance as required (See Maintenance Section). 8. Provide a means of pressure relief for pumps whose discharge line can be shutoff or obstructed. 9. Personal Safety: a. Wear safety glasses at all times when working with pumps. b. Keep work area clean, uncluttered and properly lighted; replace all unused tools and equipment. c. Keep visitors a safe distance from the work area. Make workshop childproof with padlocks, master switches, and by removing starter keys. 10. When wiring an electrically driven pump such as this, follow all electrical and safety codes, as well as the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). Specifications Power supply requirements.............120V, 60 hz Circuit requirements ........................15 amps (min) Motor duty .......................................Intermittent Motor ................................................120V, 1 Phase Horsepower .....................................6/10 (DSP60), 3/4 (DSP75) Motor full load.................................11.3A (DSP60), 11.8A (DSP75) Liquid temperature range...............40°F to 120°F Max. operating position..................45o from vertical Dimensions .......................................14” x 12” Intake ................................................2” Discharge ..........................................2” NPT female Power cord........................................16 gauge 3 conductor w/plug Construction Motor body material .......................Cold rolled steel Motor housing .................................Cast iron Volute ...............................................Cast iron Impeller.............................................Cast iron Seal plate ..........................................Cast iron Shaft seal ..........................................Mechanical Performance GALLONS PER HOUR AT TOTAL HEAD IN FEET Model 0’ 5’ 10’ 15’ 20’ 25’ DSP60 8200 7500 6000 4000 2000 — DSP75 8800 8160 7080 4920 2880 700 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. For parts, product & service information © 2003 Wayne Water Systems 330600-001 6/03visit Operating Instructio...

Este manual também é adequado para os modelos :
Canalização - 330600-001 (274.8 kb)
Canalização - DSP60 (274.8 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias