Log:
Assessments - 4, GPA: 3.3 ( )

Instruções de Operação Wayne, Modelo 330600-001

Fabricante : Wayne
Arquivo Tamanho: 274.8 kb
Arquivo Nome : 9e094aa5-44b0-488c-a07a-5554affd7c07.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


4. Place the pump in a suitable area where it can be cleaned thoroughly. Remove all scale and deposits on pump. 5. Submerge the complete pump in a disinfectant solution (10% chlorine bleach solution) for at least one hour before handling the pump. 6. Clean all dirt and deposits from the pump float. Make sure float moves freely after cleaning. 7. Clean all dirt and deposits away from pump inlet and volute. This pump contains dielectric motor oil for lubrication and motor heat transfer. This oil can be harmful to the environment. Check state environmental laws before disposing of this oil. This oil can be harmful to aquatic life so consideration should be exercised in the application of this pump. Limited Warranty For three years from the date of purchase, Wayne Water Systems (“Wayne”) will repair or re place, at its option, for the original purchaser any part or parts of its Pond Kit, Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or work man ship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be pre pared to provide the model and serial number when exercising this warranty. All trans por ta tion charges on Products or parts submitted for repair or replacement must be paid by purchaser. This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper main te nance, or failure to operate in accordance with Wayne’s written instructions. THERE IS NO OTHER EXPRESS WARRANTY. IM PLIED WARRANTIES, IN CLUD ING THOSE OF MER CHANT ABIL I TY AND FITNESS FOR A PARTICULAR PUR POSE, ARE LIMITED TO THREE YEARS FROM THE DATE OF PUR CHASE. THIS IS THE EXCLUSIVE REM E DY AND ANY LIABILITY FOR ANY AND ALL IN DI RECT OR CON SE QUEN TIAL DAM AG ES OR EX PENS ES WHATSOEVER IS EXCLUDED. Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above lim i ta tions might not apply to you. This limited war ran ty gives you specific legal rights, and you may also have other legal rights which vary from state to state. In no event, whether as a result of breach of contract warranty, tort (in clud ing negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equip ment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s cus tom ers for such damages. You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return authorization and instructions. DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records. MODEL NO. _____________________ SERIAL NO. ________________________ INSTALLATION DATE _____________________ ATTACH YOUR RECEIPT HERE 3 Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Pump will not start or run 1. Water level too low 1. Pump switch will not turn on unless water covers top of pump 2. Blown fuse or tripped circuit breaker 2. If blown, replace with proper sized fuse or reset breaker 3. Low line voltage 3. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company. 4. Defective motor 4. Return for service or replace motor 5. Defective float switch 5. Replace float switch 6. Impeller (pump filled with debris) 6. If impeller will not turn, remove volute and remove debris 7. Tangled switch 7. Arrange switch so the switch moves freely. Reposition pump if necessary 8. Insufficient liquid level 8. Make sure liquid level is adequate Pump starts and stops too often 1. Backflow of water from piping 2. Faulty float switch 1. Install check valve 2. Replace float switch 3. Check valve not installed or leaking 3. Remove and examine check valve for proper installation and free 4. Discharge head is less than operation manufacturer's minimum 4. Recheck all sizing calculations to determine proper pump size Pump shuts off and turns 1. Excessive water temperature 1. Pump should not be used for water above 120° on independently of 2. Defective switch or entangled switch 2. Replace or reposition pump switch (trips thermal is causing pump to run dry overload protection) Pump may start unexpectedly. Disconnect power supply before ser vic ing 3. Low line voltage 3. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company Pump operates noisily or vibrates excessively 1. Worn bearings 2. Debris in impeller cavity or broken 1. Return for service or replace ...

Este manual também é adequado para os modelos :
Canalização - DSP60 (274.8 kb)
Canalização - DSP75 (274.8 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias