Log:
Assessments - 5, GPA: 4 ( )

Instruções de Operação Hans Grohe, Modelo Metro E 0657000

Fabricante : Hans Grohe
Arquivo Tamanho: 5.13 mb
Arquivo Nome : hruh0138.pdf
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


water pressure Pression d’eau maximum 147 psi Recommended hot water temp. Temperature recommandee d'eau chaude 120.. - 140.. F* Max. hot water temp Temperature maximum d'eau chaude 158..F* Flow rate of handshower Debit de douchette 2.5 gpm Flow rate of each bodyspray Debit de chaque jet mural <1.0 gpm Flow rate of thermostatic mixing valve Debit maximum du mitigeur thermostatique 8 gpm @ 45 psi 10 gpm @ 65 psi *Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. * Vous devez connaitre et respecter tous les codes de plomberie locaux applicables pour le reglage de la temperature du chauffe-eau. Installation considerations English Check package contents Before beginning installation, check the contents of this package. Make sure that all parts are present and in good condition. If any part is missing or damaged, please contact Hansgrohe Customer Service before proceeding. Tools required The following tools are suggested for installing the showerpanel: Tape measure Level Grease pencil or other marking device Drill with 6 mm bit suitable for wall surface 10 mm nut driver 10, 11 and 19 mm wrenches • • • • • • 3 mm Allen wrench Philips screwdriver Waterproof sealant Mallet (to install anchors) Teflon tape • • • • • Francais – voir p. 17 For best results, Hansgrohe recommends that this unit be installed by a licensed, professional plumber. Please read over these instructions thoroughly before beginning installation. Make sure that you have all tools and supplies needed to complete the installation. This product is listed by IAPMO and is approved for use in Massachusetts. • • • Protection against backflow provided by check valve in the handshower outlet. The high temperature limit stop on the thermostatic mixing valve may be reset to comply with local plumbing codes* -- see page 13. • • *In Massachusetts, the maximum output temperature cannot exceed 112°F. English Rough-in This unit can be installed on a flat wall or in a 90° corner. Instructions for installation on a flat wall begin on page 5. Go to page 8 if the panel is to be installed in a corner. Ensure that you have a minimum 83" ceiling height from the standing surface. Stub out 1/2" NPT male nipples for the hot and cold water supplies at the locations shown on the appropriate rough-in Installation on a flat wall diagram. The nipples should extend 5/8" outside the surface of the finished wall. Install the wall surface and make the wall watertight before installing the panel. The panel hangs on the finished wall. Seal the wall around the nipples with waterproof sealant. Failure to seal the wall can lead to possible water damage. Installation in 90° corner Installation .. flat wall Wrap the threads on the nipples with Teflon tape. Install the elbows so that the outlets face upwards. Measure up the wall 78 .", making sure that the line is plumb. Mark the position for the top screw hole. From the position of the top screw hole, measure down 35 3/...

Este manual também é adequado para os modelos :
Canalização - Metro E 0657000 (5.13 mb)
Canalização - Metro E 0657000 (5.13 mb)
Canalização - Metro E 06573000 (5.13 mb)
Canalização - Metro E 06573000 (5.13 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias