Log:
Assessments - 5, GPA: 4.2 ( )

Instruções de Operação Axor, Modelo Metro E 06573000

Fabricante : Axor
Arquivo Tamanho: 5.13 mb
Arquivo Nome :
Língua de Ensino:
Ir para baixar



Facilidade de uso


Installation in 90° corner Installation .. flat wall Wrap the threads on the nipples with Teflon tape. Install the elbows so that the outlets face upwards. Measure up the wall 78 .", making sure that the line is plumb. Mark the position for the top screw hole. From the position of the top screw hole, measure down 35 3/8”. Mark the position for the center screw hole. From the center screw hole, measure down 19 1/8". Mark the position for the bottom screw hole. Use a 6 mm bit to drill the three screw holes. Install the set screws in the top and bottom holes. Use a 10 mm nut driver to attach a nut to the top set screw. Slide the panel over the top and bottom set screws. Tighten the nut on the top set screw. Install and tighten the nut on the bottom set screw. Install one recessed head screw and the large washer on the center hole. Tighten the screw. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. English Use the compression nuts and ferrules to connect the supply hoses on the panel to the supply elbows. Use two wrenches, as shown, to prevent the supply hoses from twisting. Attach the seals to the side covers. Install the side covers. The pins on the covers must go into the grooves on the sides of the panel. English Push the bodyjet supply hose on the valve cover into the fitting on the panel. Install the valve cover on the panel. The pins on the cover must connect to the slots on the panel. Turn to page 11 to continue the installation. English English Installation in 90° corner Wrap the threads on the nipples with Teflon tape. Install the elbows so that the outlets face upwards. In the corner, measure up the wall 78 .", making sure that the line is plumb. Mark the position for the top mounting bracket. From the position of the top screw hole, measure down 35 3/8". Mark the position for the center mounting bracket. From the center screw hole, measure down 19 1/8". Mark the position for the bottom mounting bracket. Use the mounting brackets as templates to mark the positions of the screw holes. Drill the holes with a 6 mm bit. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Install the mounting brackets to the walls using five of the recessed head screws. Install the corner sealing gasket to the grooves on the panel. While a helper holds the panel, attach the supply hoses to the elbows with the compression fittings. Use two wrenches, as shown in the diagram, to prevent the supply hoses from twisting. Tighten the hex head cap screw on the top mounting bracket. Install and tighten the hex head cap screw on the bottom mounting bracket through the hole in the panel and tighten. Install the hex head cap screw and large washer on the center mounting bracket through the hole in the panel and tighten. English 10 Clip the side cover seals as shown in the diagram. Attach...

Este manual também é adequado para os modelos :
Canalização - Metro E 0657000 (5.13 mb)
Canalização - Metro E 0657000 (5.13 mb)
Canalização - Metro E 0657000 (5.13 mb)
Canalização - Metro E 06573000 (5.13 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias