HP PCI Tachyon XL2 Fibre Channel Driver Release Notes
Known Problems and Workarounds
Known Problems and Workarounds
Following is the known problem and workaround in the HP PCI Tachyon TL/TS/XL2 Fibre Channel driver:
•
Problem: The A6795A Fibre Channel adapter settles in the Public Loop topology as opposed to the Point
to Point Fabric topology when connected to a 4Gb Fibre Channel Brocade Switch port.
Symptom: The /opt/fcms/bin/fcmsutil /dev/
expected PTTOPT_FABRIC output, against the Topology field.
The /dev/
to the 4Gb Brocade Switch port.
Workaround: Configure the Brocade switch port that is connected to the A6795A Fibre Channel adapter, as G port.
Use the telnet command to connect to the switch. To enable the G port settings, enter the following command at the
switch prompt:
switch> portcfggport
The following message is displayed at the switch prompt:
Committing configuration...done.
For more information about the portcfggport command, use the help command:
switch> help portcfggport
For detailed information about the portcfggport command, see the manpage and Release Notes for the
Brocade switch present at:
http://www.brocade.com/index.jsp
To turn off the G port settings, enter the following command at the switch prompt:
switch> portcfggport
The following message is displayed at the switch prompt:
Committing configuration...done.
Chapter 1
13
...
categorias
instruções de Pesquisa
Já vistos
- HP HP Fibre Channel Host Bus Adapters
- HP HP Jetadmin Software for SunOS
- HP HP Surestore Director fc-64
- HP HP Jetadmin Software for SunOS
- Black & Decker Perfect Broil CTO4400B-05G
- Woods Equipment BATWING ROTARY CUTTER BW1620XQREV
- Newcon Optik SPOTTING SCOPE 15-45X60
- Edelbrock For Big-block Chevrolet V8 8851
- Badger Basket Cherry Doll Changing Table 01867
- Chicago Electric HARBOR FREIGHT TOOLS 98753