Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação HP, Modelo HP Fibre Channel Host Bus Adapters

Fabricante : HP
Arquivo Tamanho: 71.17 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


HP PCI Tachyon XL2 Fibre Channel Driver Release Notes
Known Problems and Workarounds
Known Problems and Workarounds
Following is the known problem and workaround in the HP PCI Tachyon TL/TS/XL2 Fibre Channel driver:

Problem: The A6795A Fibre Channel adapter settles in the Public Loop topology as opposed to the Point
to Point Fabric topology when connected to a 4Gb Fibre Channel Brocade Switch port.
Symptom: The /opt/fcms/bin/fcmsutil /dev/ tool displays PUBLIC_LOOP in the output instead of the
expected PTTOPT_FABRIC output, against the Topology field.
The /dev/ is a device file that corresponds to the A6795A Fibre Channel adapter that is connected
to the 4Gb Brocade Switch port.
Workaround: Configure the Brocade switch port that is connected to the A6795A Fibre Channel adapter, as G port.
Use the telnet command to connect to the switch. To enable the G port settings, enter the following command at the
switch prompt:
switch> portcfggport , 1
The following message is displayed at the switch prompt:
Committing configuration...done.
For more information about the portcfggport command, use the help command:
switch> help portcfggport
For detailed information about the portcfggport command, see the manpage and Release Notes for the
Brocade switch present at:
http://www.brocade.com/index.jsp
To turn off the G port settings, enter the following command at the switch prompt:
switch> portcfggport , 0
The following message is displayed at the switch prompt:
Committing configuration...done.