Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação HP, Modelo HP Fibre Channel Host Bus Adapters

Fabricante : HP
Arquivo Tamanho: 394.14 kb
Arquivo Nome :
Língua de Ensino: enda
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


Table 6 HP-UX December 2008 Fixes
Defect ID
Description
QXCR1000867632
The fix delivers the SNIA API HBA_GetFcpTargetMappingV2(), which is used to oormation
about the targets mapped through a port on a multiport Fibre Channel card.btain inf
QXCR1000841117
vPars boot panic with AD222 HBA has been fixed.
QXCR1000869847
System panic due to spinlock being held too long in a tracing loop has been fixed.
QXCR1000886304
The case where the fclp driver did not recognize a device with a loop ID of zero on a private
loop has been fixed.
Table 7 HP-UX September 2008 Fixes
Defect ID
Description
QXCR1000799018
Fixed an issue which caused system dump failure to an fclp attached device, if base page size
was set to a value other than 4 KB.
QXCR1000753480
Long hardware path from AD221A (PCIe 1 port 4Gb FC and 1 port GigE HBA) card not
recognized by vparmodify. The workaround for this issue is located at the following
address:http://docs.hp.com/en/T1335-90091/ar01s05.html
NOTE:
AR0803 was the initial release of FibrChanl-02 (fclp) on HP-UX 11i v3.
Known problems and limitations
This section provides a list of known problems and limitations as known to HP at time of
publication. If workarounds are available, they are included.

A voltage degradation alert message is shown in the System Events Logs upon system
boot up

This is only an alert message for the 456972-B21 HBA. Functionality and performance on
the Mezzanine card are not adversely affected. No actions are needed. This message can
only be found through the SL command under the MP menu.

EFI is only bootable from the first boot entry device
This applies to the first boot entry device that is connected to an AD221, AD222A, AD393A,
AD299A, or AD355A.
Corrective action: The workaround for this issue is to re-arrange the boot list that is connected
to the adapters:
1.
Select Boot Options Maintenance Menu from the EFI Boot Manager's main menu.
2.
Use the following three Boot Options Maintenance Menu items to edit the boot
options list, so that the fibre device connected to an AD221A, AD222A, AD393A,
AD299A, or AD355A is listed as the first entry in the boot options list:
— Add A Boot Option: presents you with a list of possible boot devices, and
allows you to select one to add to your boot options list.
— Delete Boot Option(s): allows you to interactively delete one or more entries
from your boot options list.
— Change Boot Order: allows you to re-order your boot options list.
3.
When the boot options list for your system has been re-ordered as you wish, select Exit
to return to the EFI Boot Manager's main menu, which should now reflect your edits
to the boot options list.

EFI boot fails with no HP-UX partition on boot media message
Loading.: HP-UX Primary Boot: 0/4/0/0/0/0.8.0.20.0.3.0
Starting: HP-UX Primary Boot: 0/4/0/0/0/0.8.0.20.0.3.0
6


...