Known problems and limitations
This section provides a list of known problems and limitations as known to HP at time of publication.
If workarounds are available, they are included.

FlexFabric and Converged Network Adapters Must Be Disconnected From All Boot Devices
Before Flashing Latest Firmware
Integrity FlexFabric and Converged Network Adapters must be updated offline to firmware
version 3.704.356.3 for 613431-B21 and AT111A and firmware version 2.704.356.3 for
580151-B21 or later before putting in use. Additionally, the user must unload the FCOC UEFI
driver prior to performing the firmware update or the system may crash.
For additional information, please refer to HP Customer Advisory Document ID c0314831.

HP Virtual Connect FlexFabric 10Gb/24-Port Module firmware version
A fix in AR1203 exposes an issue with the HP VC FlexFabric 10Gb/24-Port Module
(QXCR1001194681) that causes fcmsutil to incorrectly display the Previous Topology as
UNINITALIZED whenever the link goes down. Please see QXCR1001194681 for more
information and the minimum firmware version required for the HP Virtual Connect FlexFabric
10Gb/24-Port Module when the fix becomes available.

Up to a total of eight NC551m and/or NC553m HBAs are supported in a BL890c i2 system.
Up to a total of 140 Fibre Channel ports, which can be any combination of CN1100E and
AT094A HBAs, are supported in a Superdome2 system.

The HP-UX boot path is lost during un-assign and re-assign of the BL8x0C i2 (Blade) profile.
The scenario that leads to this is:
1.
Create a profile and assign it to the blade. Install a SAN disk connected from HBA with
HP-UX on it.
2.
Power off the blade.
3.
Un-assign the profile from the blade.
4.
Power on the blade to EFI shell (bare-metal state).
5.
Power off the blade.
6.
Re-assign the profile back to the same blade.
7.
Power on the blade again.
At this point, the blade should be booted from HP-UX and be up and running. However, the
blade remains in Ignite-UX and waits to be re-installed again.
NOTE:
In order to reproduce the problem, a power cycle is necessary between the un-assign
and re-assign profile steps. Without the power cycle between the un-assign and re-assign
profile, the problem does not occur.

To enable booting through the fcoc driver, there are several steps that needed to be performed.
They involve invoking the Emulex Configuration Utility at the EFI level. These steps need to be
performed only once. They need to be done regardless of the VCM profile settings.
To start the Emulex Configuration Utility via the Human Interface Infrastructure (HII):
1.
Launch the Device Manager. A front page is displayed.
Known problems and limitations
5


...