|
Facilidade de uso
U135ME3A COM X - fmr RL RM RH STR STF Drive Control Connections V-COMPUTER OUTPUT BOARD Figure 41 U136ME3A J8 J2A 30 31 32 33 34 35 J7A J3B J1 Ribbon Terminals 1 thru 16 Terminals 17 thru 29 Drive Control Connections U136ME3A WE-6 INTERFACE BOARD Figure 42 U148ME3A 1 7 6 12 H2 H4 H1 H3 H5 Drive Control Connections EDC OUTPUT BOARD Figure 43 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 1305-Series AC Drives Control Wire During troubleshooting, if the wire path between the control board and the drive is uncertain, refer to Table 44 for wire connection numbers. Control Wire Connection Reference Table. Output Board Terminal V-Control F370314, F8206501 and F370447-6, etc. STF 6 STR 13 RH 18 RM 17 RL 16 COM 7 WE-6 Interface Board P/N: F370577, F0370446-xx J2A-30 7 J2A-31 17 J2A-32 6 J2A-33 18 J2A-34 16 J2A-35 13 EDC – Output Board P/N: F370433 H2-7 18 H2-8 17 H2-9 16 H2-10 7 H2-11 13 H2-12 6 Table 44 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT F232120 AC Drive Diagnostics/Parameter Viewing Human Interface Module (HIM or Parameter Unit) Installation/Removal The following are instructions for installing/removing the Human Interface Module (P/N F370597) on the drive for parameter viewing and basic troubleshooting. The parameter unit (F370597) and instructions (F232120) are included in the Parameter Kit (P/N F744501). CAUTION Users are prohibited from changing parameter values unless specifically instructed by the washer-extractor manufacturer. Modification to parameter values may present potential harmful operating conditions for both hardware and personnel. W673 WARNING To reduce risk of electric shock, severe injury or death, allow machine power to remain off for three minutes minimum prior to working in and around AC drive. Proceed with caution. W662 Installing the HIM 1. Remove power from machine at main disconnect. Delay approximately three minutes. 2. Lower the hinged panel located below the HIM. Allen-Bradley 1305-Series AC Drives 3. Slide blank panel cover toward base of drive and remove it. Place top edge of HIM approximately 1/2 inch from top edge of the cover. Push inward on bottom of HIM and slide HIM up (toward the top of the drive) into position. Removing the HIM 1. Remove power from machine at main disconnect. Delay approximately three minutes. 2. Lower hinged panel located below HIM. 3. Press retaining lever located directly beneath HIM. Slide HIM downward and remove it from drive. 4. Reinstall blank panel cover. Close hinged panel. External HIM Connection The HIM unit can be installed using an adapter cable (P/N P370716). This method of attaching the HIM uses an external connector shown in Figure 44. The HIM unit operates in the same manner in this configuration. NOTE: If the HIM is removed while the drive is powered, a communication fault (Serial Fault #10) will occur and the drive will be disabled. Cycle power to the drive to reset the fault condition. Figure 44 Human Interface Module Hinged Panel Retaining Lever External HIM Cable Connection Blank Panel Cover ESC SEL Stopped+0.00 Hz U079ME3A F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 1305-Series AC Drives Human Interface Module (HIM) Operation When power is first applied to the drive, the HIM will cycle through a series of displays. The displays will show drive name, HIM ID number, and communications status. Upon completion, the Status Display will be displayed. If a fault condition exists, it will appear on the display. NOTE: If “Not Enabled” is displayed, the Enable input is not active. Check that the door is closed and locked, or that all necessary jumpers are in place. Refer to Section 2 of this manual. Figure 45 ESC SEL Stopped +0.00 Hz U093M Human Interface Module (HIM) HIM – Key Explanation ESC Escape key. Use to return to last or original position. Select key. Use to move cursor position. SEL Up arrow key. Scroll up. Down arrow key. Scroll down. Enter key. Use to enter program selection or new parameter value. The structure charts on the following pages illustrate how to navigate between the levels to obtain information necessary for troubleshooting for earlier and later HIM versions. The HIM Structure is broken into 4 levels: Operator Level, Mode Level, Group Level (Main File for earlier versions), and Parameter Level. In the Group Level (Main File for earlier versions), only three Groups are used: Metering, Faults, and Linear List. Most diagnostic information is found in Metering or Faults. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT F232120 Allen-Bradley 1305-Series AC Drives HIM Structure Chart – Series A 3.00, Series B 1.01 or Later Versions Diagnostics Ratings (1336 only) Masks Owners Adapter I/O Process Display Encoder Feedback (1336 only) Setup Advanced Setup Frequency Set Feature Select Output Config PARAMETER LEVEL Power-Up Mode & Status Display Output Current Output Voltage Output Power DC ...
Este manual também é adequado para os modelos :Máquinas de lavar - 1336 (1.29 mb)
Máquinas de lavar - 1305 (1.29 mb)