Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Bryant, Modelo LEGACY LINE--RNC T1--PHP

Fabricante : Bryant
Arquivo Tamanho: 173.21 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Cooling Operation 1. Press H/C button until COOL is displayed. 2. Press DOWN button until LCD readout reads 3_/1.7_C below room temperature. Press UP and FAN buttons simultaneously to defeat timers. Cooling system should begin to operate immediately. Table 1 shows the thermostat outputs for each available stage of heating or cooling. It may be useful in checkout or troubleshooting. T1PAC/ T1PHP 3 Table 1 – Outputs T1PAC/ T1PHP EQUIPMENT HEAT CONFIGURATION EM HEAT STAGE 2 OPTION #1 Y,G,W W HP, PH HP Y,G Y,G,O/B Y,G,W,O/B W RVS = H THERMOSTATFACTORYCONFIGURATIONCOOLSTAGE1HEATSTAGE1AC,PCAC,HPY,GWHP,PHRVS=CHPY,G,O/BY,G WIRING DIAGRAMS A06566A06567 Fig.1- --A/CThermostatTypicalInstallationFig.2- --HPThermostatTypicalInstallation E2008 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 02/08 Catalog No. IIT1- ---PAC---04 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Replaces: IIT1---PAC---03 4 T1PACT1PHPLEGACYLINERNCPROGRAMMABLETHERMOSTATST1PACT1PHPLEGACYLINERNCPROGRAMMABLETHERMOSTATS Homeowner’s Guide A07109 Legacy Line--RNC Series Programmable Thermostat SETTING TIME AND DAY At Power Up When power is first applied, AC or HP will appear for 5 seconds to tell you it is an air conditioner (AC) or a heat pump (HP) model. After this, the time display will flash to tell you the power has been off. Setting The Current Time: 1. Press the TIME/TEMP button. SET TIME flashes on the display. 2. Press the UP or DOWN button until the correct time is displayed. 3. To quickly advance to the proper time, press and hold the UP or DOWN button. 4. When the correct time appears on the display, press the HOLD/END button. NOTE: If you choose not to press the HOLD/END button, the thermostat will automatically exit the time setting mode after 10 seconds. Setting The Current Day: 1. Press the DAY button to advance to the correct day. 2. When the correct day appears on the display, press the HOLD/END button. MANUAL OPERATION To Operate Manually (Without the Programmed Comfort Schedule): Press the HOLD/END button to make the HOLD icon appear. Then follow the four steps below: 1. To Select the Mode: Use the H/C button to move between the choices. OFF, HEAT, COOL, or EMHT will appear on the display. EMHT will only appear on heat pump models. 2. To Select the Fan Operation: Use the FAN button to move between continuous fan (indicated by the FAN ON icon) and auto fan operation. 3. To Read the Room Temperature: The large display reads room temperature until a button is pressed. 4. To Adjust the Setpoint: In normal operation, the large display shows room temperature. At the first press of the UP or DOWN button, the large display shows the current setpoint and the SET TEMP icon is turned on. Further presses of the UP or DOWN button adjust the setpoint upward or downward. Five seconds after the last button press, the display returns to the room temperature and the SET TEMP icon turns off. PROGRAMMED OPERATION Introduction The Legacy Line--RNC Series Programmable Thermostat provides four periods per day (MORNING, DAY, EVE, NIGHT) and two schedules per week (MoTuWeThFr and SaSu). A separate time, heat setpoint, and cool setpoint can be set for each period and schedule. Before starting to actually program the thermostat, fill out Table 1 with the values you wish to program. (The Energy Starr, US Department of Energy recommended time and temperature values are already programmed for you as a starting point and are shown on the left side of the table.) The first press of the PROGRAM button brings up the programming mode and places you at morning of the current day and period. Successive presses move you between the four daily periods. While Programming: The TIME/TEMP button moves between three selections of SET TIME, SET TEMP & HEAT, and SET TEMP & COOL. These three numbers are to be programmed for each of the periods MORNING, DAY, EVE, and NIGHT. The DAY button moves between the weekdays, (MoTuWeThFr) and the weekend (SaSu) selections. A different schedule may be set for the weekdays and the weekend. You may exit programming at any time by pressing the HOLD/END button. Programming A Weekly Comfort Schedule: 1. Press the PROGRAM button. The word PROGRAMMING appears on the display and the words SET TIME flash on the display. MoTuWeThFr or SaSu and the morning period icons will appear on the display. The current mode (HEAT or COOL) will also show. Use the DAY button to select weekdays and the PROGRAM button to select MORNING. T1PAC/ T1PHPT1PAC/ T1PHP 2. Press the UP or DOWN button to set the start time for MORNING ( 1) value in Table 1). 3. Press the TIME/TEMP button until COOL is on and SET TEMP flashes on the display. 4. Press the UP or DOWN button to select the cooling temperature setpoint ( 2) value in Table 1). 5. Press the TIME/TEMP button until HEAT is on and SET TEMP flashes on the display. ...

Este manual também é adequado para os modelos :
Os termostatos - LEGACY LINE--RNC T1--PAC (173.21 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias