Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Broan, Modelo FM 2500DD-A

Fabricante : Broan
Arquivo Tamanho: 413.43 kb
Arquivo Nome : 1d4de783-9a79-4b11-a5a0-a07837c1a8d8.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


In the event of fire, the downdraught extractor must be switched off. Put out the fire with a lid. Never use water. Check that the downdraught extractor is turned off when not in use. Cleaning and Maintenance For hygiene and safety reasons the downdraught extractor must be kept clean. In a worst case scenario, a clogged fat filter can ignite and burst into flames. Service Service and repair must be performed by our service organisation or an organisation approved by us. Only spare parts supplied by our service organisation may be used. Unpacking Make sure the packaging is disposed of in such a manner that children cannot access the used packaging. 5 Installation The downdraught extractor may only be installed by an authorised electrician or someone approved by the manufacturer. Work carried out by unqualified persons can lead to personal injury and/or damage to property and may damage the downdraught extractor. During installation make sure the electricity cable is not pinched. Do not interfere with the down- draught extractor electrical parts. Extracted air must not be connected to a duct that is already used to discharge flue gases from an oil-fired boiler or similar. Disposal Help to avoid accidents when throwing out the downdraught extractor. Remove the electricity cable from the wall socket and cut it off close to the downdraught extractor. Product Description Control Panel 7 8 3 2 4 5 6 1 1. On/off 2. Raise the downdraught extractor 3. Lower the downdraught extractor 4. Set the extraction rate 5. Intensive extraction 6. Minute timer 7. Extraction rate display 8. Minute display 7 Downdraught Extractor The air is sucked in at the air dampers through the fat filter and is then blown via the extraction hose to the extraction duct and out into the open air. Height positions When installed beside electrical appliances, the downdraught extractor can be adjusted continuously from the centre position to the top position. When installed beside a gas appliance, the down- draught extractor can only extract in the top position. Extraction rates The downdraught extractor has 4 different extraction strengths: 150m3/h, 220m3/h, 345 m3/h and 480 m3/h. Electronic control system The downdraught extractor has an electronic control system. The electronics have the following functions: -Extraction rate display -Timer-controlled operation -Autostop -Grease filter cleaning indicator How to use Downdraught Extractor Never leave the down- draught extractor unattended when deep-frying or melting fat or other easily ignited substances. Do not flambe food in the immediate proximity of a downdraught extractor that is switched on. This can cause fire. In the event of fire, the downdraught extractor must be switched off. Put out the fire with a lid. Never use water. Finger Touch The buttons have to be touched for at least 1 second before they are activated. If the buttons are touched for more than 10 seconds, the downdraught extractor will be switched off automatically. If two buttons are touched at the same time, neither of the settings is registered, apart from resetting the indicator for cleaning the fat filter. The downdraught extractor can always be switched off by pressing the k button. 9 Downdraught Extractor 1. To turn the downdraught extractor on, press k. 2. To select the height position, press m. The downdraught extractor will move to middle position and switch on at extraction rate 1. To turn the downdraught extractor off, hold l down until bottom position has been reached. Pressing k will turn extraction off, but the downdraught extractor will remain where it is and not descend into the worktop. Height positions Installation beside electrical appliances The downdraught extractor is variable between the middle and top position. Raising The downdraught extractor is switched on. Select the height position within 10 seconds. 1. Press m. The downdraught extractor will move to middle position. The dampers are deployed. 2. Press m again. 10 The downdraught extractor will then stop rising automatically when the button is released or when top position is reached. Safety If the downdraught extractor is obstructed when raising, it will switch off automatically. Lowering 1. Press l. If you keep pressing l, the down- draught extractor will move steplessly between the top and bottom position. It will stop when you release the button. When the middle position is reached, the dampers retract and extraction is turned off. Installation beside gas appliances The downdraught extractor can only extract in top position. 11 Raising When the downdraught extr...

Este manual também é adequado para os modelos :
Fans - FM 2500DD-A (413.43 kb)
Fans - FM 2500DD-A (413.43 kb)
Fans - FM 2500DD-A (413.43 kb)
Fans - FM 2500DD-A (413.43 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias