Fabricante : Electrolux
Arquivo Tamanho: 592.86 kb
Arquivo Nome : 2f60fba8-76b3-1644-fd9e-ad09a7c28bec.pdf
|
Facilidade de uso
• For wooden shelf, drill o 7 mm. • For the power supply cable feed, drill o 10 mm. • For the air outlet (Ducted Version), drill according to the diameter of the external air exhaust duct connection. • Insert two screws of the following type, crossing them and leaving 4-5 mm from the ceiling: • For concrete ceilings, use the appropriate plugs for the screw size (not provided). • For Cavity ceiling with inner space, with wall thickness of approx. 20 mm, Screws (not provided). • For wooden beam ceilings, use 4 wood screws (not provided). • For wooden shelf, use 4 screws with washers and nuts (not provided) Fixing the Frame • Loosen the two screws fastening the lower chimney and remove this from the lower frame. • Loosen the two screws fastening the upper chimney and remove this from the upper frame. If you wish to adjust the height of the frame, proceed as follows: • Remove the eight metric screws joining the two columns, located at the sides of the frame. • Adjust the frame to the height required, then replace all the screws removed as above. • Insert the upper chimney stack from above, and leave it running free on the frame. ........ • Lift up the frame, fit the frame slots onto the screws up to the slot end positions. • Tighten the two screws and fasten the other two screws provided with the hood. Before tightening the screws completely it is possible to adjust the frame by turning it. Make sure that the screws do not come out of their seats in the slotted holes. • The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device. On completion, check that the base is stable, even if the frame is subjected to bending. Extraction (Ducted) The cooker hood is more effective when installed in the extraction mode (ducted to the outside). Venting kits may be purchased through your local John Lewis store, and must be evacuated through an outside vent of o125 (5ins) or o150mm (6ins). The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102-B1. When the cooker hood is ducted to the outside the charcoal filter must be removed. Fitting the Ducting • Fit the o150mm (6ins) ducting to the spigot on top of the hood body as illustrated. • When using o125mm (5ins) ducting fit item 9 and 10 on to the spigot on the top of the hood body as illustrated. • For the best performance use the shortest possible run of ducting and we recommend the use of rigid pipe in preference to flexible hose as this will improve the flow of air while reducing turbulence, which causes noise and a loss of performance. • If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler, then its flue must be of the "room sealed" or "balanced flue" type. • If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room. • The cooker ducting when fitted in the extraction mode must never be connected to central heating flues, radiators or water heaters. ......... .... ......... 10 .. Recirculation Mode The cooker hood is supplied specified for use in the recircula tion mode, with the charcoal filter fitted. In the recirculation mode contaminated air is passed through the charcoal filter to be purified and recirculated into the kitchen through the grille outlets on either side of the chimney. • Assemble the two halves of the ducting extension pipe item 14. • Push-fit the extension pipe onto the ducting spigot on top of the canopy. • Push-fit the recirculation adapter item 15 on to extension pipe item 14. • Insert the recirculation outlet extensions item 14.4 into the recirculation adapter item 15. • The recircualtion grilles item 8a and 8b must be fitted after the lower chimney item 2.2 has been fitted. • Ensure the activated charcoal filter has been fitted. Chimney Stack The chimney consists of two sections. The lower chimney measures 740mm and the upper chimney (with the recirculation grilles on either side) measures 215mm. The overall installed measurement is min. 740 -max 940mm. Fitting the Chimney • Position the upper chimney section and fix th...
Este manual também é adequado para os modelos :Fans - JLBIHD906 (592.86 kb)
Fans - JLBIHD906 (592.86 kb)
Fans - JLBIHD906 (592.86 kb)
Fans - JLBIHD906 (592.86 kb)