Log:
Downloads : 0   Arquivo Tamanho: 947 kb   Fabricante : Field Controls  
Categoria : Fans
@name@name@name

The Type “C” Draft Inducer is installed on the top of the vent system outside of the building. English .......Page 1 Francais .....Page 4 Espanol ......Page 6 Page 2 INSTALLATION SMOKE PIPE, TYPE “B” VENTS AND TYPE ”L” VENTS 1. Insert the Type “C” housing directly into the vent pipe. (See Figure 1) 2. Fasten housing to vent pipe using three (3) sheet metal screws, located 120. apart. 3. Seal joint with a high temperature silicone adhesive sealant MASONRY CHIMNEYS 1. Measure the size of the chimn

Downloads : 0   Arquivo Tamanho: 819 kb   Fabricante : Field Controls  
Categoria : Fans
@name@name@name

By maintaining constant air flow through the crawl space, problems such as fungus growth, dry rot, and radon gas will be reduced or eliminated. An integral temperature switch allows fan operation only at air temperature above 50°F. EL-1 UNIT INCLUDES: 120 volt ELIMINATOR™ fan unit with integral temperature fan control and mounting hardware. OPTIONAL CONTROL: EDH Eliminator™ De-Humidistat: 120 volt De-Humidistat to allow operation of fan at a set humidity level of the crawl space. READ THESE INST

Downloads : 5   Arquivo Tamanho: 819 kb   Fabricante : Field Controls  
Categoria : Fans
@name@name@name

Hold in place and install the supplied flat washer and hex nut. After all four (4) mounting brackets are installed, tighten nuts. (See Figure 4) Figure 1 Figure 3 Figure 4 Figure 2 MOUNTING LOCATION AND MOUNTING REQUIREMENTS 1. Locate fan on crawl space vent areas that do not have good cross flow ventilation. 2. The ELIMINATORTM fan unit must be mounted onto an existing or new crawl space vent that has a grill mesh construction. (see mounting instructions) 3. One unit is recommended per 1,000 sq

Downloads : 1   Arquivo Tamanho: 819 kb   Fabricante : Field Controls  
Categoria : Fans
@name@name@name

Ninety (90) days UV lamps/bulbs Provisions: 1. During the limited warranty period, Company, or its authorized service representative, will repair or replace, at Company’s option, without charge, a defective Product. Product that is repaired may be repaired with new or refurbished replacement parts. Product that is replaced may be replaced with a new or refurbished product of the same or similar design. Company will return repaired or replacement Product to customer in working condition. Labor ch

Downloads : 0   Arquivo Tamanho: 598 kb   Fabricante : Field Controls  
Categoria : Fans
@name@name@name

NOT CSA CERTIFIED FOR SOLID FUELS. The regulator contained in this package is manufactured with careful precision. It is designed to regulate chimney draft with a high degree of accuracy and fuel efficiency. English .......Page 1 Francais .....Page 4 Espanol ......Page 6 INSTALLATION OF TEE SECTION Locate the draft control as near to the furnace or boiler as possible. If the installation has a smokepipe stack control, locate the regulator at least 18" away from the stack control. (See Figures 3-

Downloads : 0   Arquivo Tamanho: 547 kb   Fabricante : Field Controls  
Categoria : Fans
@name

A vent pipe connector shall be supported for the design and weight of the material employed, to maintain clearances, prevent physical damage and separation of joints. A vent pipe increaser or reducer may be required for connecting the venter to the vent system. Smaller vent pipe sizes than a chimney-vented system may be used for the vent system. Route the vent pipe from the appliance to the venter using a minimum number of elbows as possible. The horizontal section of the vent pipe should have a

Downloads : 1   Arquivo Tamanho: 547 kb   Fabricante : Field Controls  
Categoria : Fans
@name

The PVO may be used to common vent multiple appliances with the addition of a Control Kit. Please consult Field Control’s Technical Support for other options. TYPICAL VENTING SYSTEM COMPONENTS One PVO Series Power Venter with pre-wired controls; adjustable post purge relay timer, adjustable draft proving switch, direct access terminal blocks, and piping tee for multiple appliance systems. • Side Wall Vent Hood (Not included) • Spill Switches (Not included) • CK-Series Control Kit for multiple ap

Downloads : 0   Arquivo Tamanho: 394 kb   Fabricante : Field Controls  
Categoria : Fans
@name@name@name

2 Francais .................................. 4 Espanol................................... 6 Page 2 INSTALLATION 1. Install in the door frame between the rooms where the temperature or air moving imbalance exists. Select the corner of the door frame which is closest to an electrical outlet. 2. Using two wood screws, mount the mounting bracket on the door frame 1” from corner. The center of the screw holes should be at least 2” away from the door when it is closed (See Fig.1). 3. Point the fan bl





categorias