Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Desa, Modelo CCL3018NA

Fabricante : Desa
Arquivo Tamanho: 4.93 mb
Arquivo Nome : 58213ddb-751d-ffb4-9970-58c18949116c.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


In the event of a power outage, you can use this heater as your primary heat source. WARNING: A qualified service person must install heater. Follow all local codes. NOTICE: State or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes. WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes, and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within house. Inspect chimney flue and firebox for damage. If damaged, repair flue before operating heater. WARNING: Seal any fresh air vents or ash clean- out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper. WARNING: Never install the heater • in a bedroom or bathroom unless installed as a vented appliance (Variable Manually-Controlled Models Only) (see page 10) • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater • in high traffic areas • in windy or drafty areas CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors. IMPORTANT:Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6. CHECK GAS TYPE Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall. MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size Side Wall Ceiling 18", 24", 30" 16" 42" LOG SIZING REQUIREMENTS Log Size Minimum Firebox Size Height Depth Front Width Rear* Width 18" 24" 30" 17" 17" 17" 14" 14" 14" 24" 28" 34" 20" 21" 24" *Measured at 14" depth Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or certified vent-free firebox. For more information, visit more information, visit 111160-01B 8 8 INSTALLATION Installation and Clearances for Vent-Free Operation (Cont.) INSTALLATION Continued Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 5. Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 5). Note:When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials. B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches. Noncombustible Requirements for Material Distance (A) Safe Installation 12" or more Noncombustible material okay. Between 8" and 12" 24" or 30" Models: Install fireplace hood accessory (GA6050, GA6052, or GA6053 see Accessories, page 28). 18" Model: Noncombustible material okay.*Minimum 16 inches from Side Wall * Example Figure 5 - Minimum Clearance for Combustible to Wall NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation,page 10. Minimum Noncombustible Material Clearances If Not Using Mantel Note:If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below. You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 6 for minimum clearances. IMPORTANT:If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vente...

Este manual também é adequado para os modelos :
Aquecedores de Água - CCL3018NTA (4.93 mb)
Aquecedores de Água - CCL3018PA (4.93 mb)
Aquecedores de Água - CCL3018PTA (4.93 mb)
Aquecedores de Água - CCL3924NA (4.93 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias