Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Bock s, Modelo 50ES

Fabricante : Bock s
Arquivo Tamanho: 180.73 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


If the valve fails to flow water or reseat, call a plumber. FIGURE 3 – 4 – CONNECT THE OIL LINE WARNING!! WHEN YOU INSTALL THE BYPASS PLUG YOU MUST RUN A TWO-LINE SYSTEM. CONNECT THE ELECTRICITY MOUNT THE OIL BURNER CONNECT TO CHIMNEY – 4 – CONNECT THE OIL LINE WARNING!! WHEN YOU INSTALL THE BYPASS PLUG YOU MUST RUN A TWO-LINE SYSTEM. CONNECT THE ELECTRICITY MOUNT THE OIL BURNER CONNECT TO CHIMNEY Inspect the incoming water line for check valves or water pressure reducing valves. Any type of check valve may cause pressure to build up in the heater and cause tank failure. If the heater is installed in a closed system or if backflow pre- venters and pressure regulators are installed, add an expansion tank. Do not try to heat hard water. Install a water softener if the heater is being used in a hard water area (water hardness more than 7 grains). An approved temperature and pressure (T&P) relief valve is factory installed in the opening provided in the upper right hand side of the heater. Pipe the T&P to within 6" of the floor or to a floor drain with a free flowing drain pipe. Do not install a check valve in the cold water line. Using “L” or “A” type venting, connect the heater to the chimney. Use the same size smoke pipe as the heater flue pipe (on models 20e, 20pp, 32E, 32PP and 33E, you may use 4" with a reducer if needed). WARNING: On Models 40E, 5OES, 50ESC, 51E, 51EC, 51PP, 51PPC. 71E and 120E, do not reduce the smoke pipe diameter. Run a separate smoke pipe from the water heater to the chimney wherever possible. If it is necessary to tee into an existing smoke pipe, be sure the connector being teed into is large enough to accommodate the products of combustion of all units attached to it. When teeing into another connector, run in at 45° angle (see Figure 1). Install a draft regulator control only if necessary. Overfire draft should not be positive. Stack draft should be -.02” W.C. minimum to -.05” W.C. maximum; CO2 should be a minimum of 11%. If a draft control is installed on the chimney, another one on the heater is not needed. The oil burner is equipped with a primary relay. An aquastat with immersion well is packed with the burner. The thermostat is factory set at 120°F for residential use (see caution on page 1 regarding temperature variations). Install the immersion well with the aquastat and check the bulb length (see “Burner & Controls” section, page 10). Remove the cardboard core from the burner opening. Mount the burner on stud bolts and place the gasket (supplied) between the burner flange and the heater. Secure the burner to the heater with 1/4 -20 nuts (supplied). Open the inspection door on the heater and check the burner tube with a mirror before firing to be sure the opening is not blocked (see Maintenance and Service sections on pages 6 and 7 for troubleshooting). All wiring must comply with applicable codes and ordinances. The primary relay is wired to the burner at the factory. Install the aquastat well in the 3/4" tappin...

Este manual também é adequado para os modelos :
Aquecedores de Água - 33E (180.73 kb)
Aquecedores de Água - 33PP (180.73 kb)
Aquecedores de Água - 40E (180.73 kb)
Aquecedores de Água - 40PP (180.73 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias