Log:
Assessments - 4, GPA: 4.5 ( )

Instruções de Operação Keating Of Chicago, Modelo Safe and Easy Filter

Fabricante : Keating Of Chicago
Arquivo Tamanho: 926.18 kb
Arquivo Nome : d0a4246d-c2bf-4c21-b9ea-e4bba9bdc263.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


13. Prepare filter tub for next useage (see section A). 14. Clean excess oil from wand and quick disconnect on the hose. CAUTION To avoid damaging the fryer, do not power wash, spray or hose it down while cleaning it. Pump must be primed with oil after boil-out with water. Failure to lubricate pump may cause severe damage to Filter System and void the warranty. FIGURE 8. 4. Push the small black knob on the filter panel to the left (“Oil to Hose”). 5. Place the nozzle of the hose in an approved discard container. 6. Drain the oil. 7. Plug the filter into the receptacle. 8. Turn the motor switch ON (the green light will illuminate). CAUTION A KEATING FRYER OR FILTER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL. WHEN DISCARDING OIL, A COVERED RECEPTACLE APPROVED FOR USE WITH HOT OIL SHOULD BE USED. USE OF A NON-APPROVED RECEPTACLE OR METHOD OF DRAINING THE OIL COULD JEOPARDIZE THE SAFETY OF THE OPERATOR. NOTE: Keep the pump turned “ON” until bubbles occur in the discard receptacle. Allow the pump to run an additional 15 seconds to clear all pipes. 9. Turn the motor switch “OFF”. 10. Push the small black knob on the filter panel to the right (“Oil to Fryer”). 11. Close drain valve of the fryer (large black knob). 12. Hose can be removed by pulling the handle on the left of the motor housing. 13. Prepare filter tub for next useage (see section A). 14. Clean excess oil from wand and quick disconnect on the hose. CAUTION To avoid damaging the fryer, do not power wash, spray or hose it down while cleaning it. Pump must be primed with oil after boil-out with water. Failure to lubricate pump may cause severe damage to Filter System and void the warranty. FIGURE 8. Connect hose here to discard oil CAUTION HOT FLUID. DO NOT FILL BEYOND MAXIMUM FILL LINE LOCATED IN THE FRYER VESSEL. Quick Hits Do’s 1. Read and follow the filtering procedure. 2. Always verify 2 connections are engaged when filtering. • Quick disconnect under the tub to the motor housing. • Quick disconnect on top of the motor housing to the fryer or central filter quick disconnect. 3. Stir the oil completely before draining. 4. Place the sump screen under the filter paper. 5. Change the filter paper for each fryer filtered. Don’ts 1. Run water through the pump. 2. Filter oil without wearing the proper attire. 3. Filter cold oil (must be between 250°- 350°). 4. Use the 6 foot hose to clean the fry tank (hose should only be used to discard the oil). 5. Powerwash, spray, or hose down the motor housing area, as electrical components are present. – 4– SAFE & EASY FILTER PARTS LIST 12 11 10 4 8 14 15 16 17 9 7 56 Front View Motor & Pump Assembly 2 3 20 19 18 1 13 – 5– Description Part No. 1. Quick Connect Coupler 052573 Compression Fitting Straight 011087 2. Caster Swivel 2” 054919 3/8-16 Acorn Nut 011763 3/8 Split Lockwasher 009085 3. Quick Connect Nipple 052572 Rubber Grommet 053445 4. Motor & Pump 052982 5. Three way valve 009354 6. Knob Black 031532 7. Filter Tub Only 14” 053444 18” 053172 20” 053123 24” 054173 8. Sump Screen 14” 052631 18” 053195 20” 053128 24” 054331 9. Filter Paper SE 14” 052932 18” 053850 20” 053850 24” 053851 10. Hold Down Ring 14” 052227 18” 053200 20” 053133 24” 054315 11. Hold Down Ring Handle 052817 Spring 006656 Collar 000512 12. Crumb Basket 14” 052662 18” 053197 20” 053130 24” 054313 13. Hose Assembly 6’ 054031 14. Quick Connect Handle 052647 15. ON/OFF switch (Not Shown) 015119 16. Quick Connect Handle to Hose (Not Shown) 053438 Acron Nut 015159 17. Quick Connect Handle 052613 18. Corrugated Flex Tubing -Pump to Tub 054864 -Valve to Quick Connect 053448 -Compression Fitting Elbow Female 006477 -Compression Fitting Elbow Male 002462 19. Roller 000520 20. Fitting 5/8 CC x 1/2 FPT 011837 Fitting 1/2 x 3/8 HEX 013743 Self-Help Guide PROBLEM PROBABLE CAUSE SOLUTION (Follow Sequentially) Motor runs but will not pump oil. Tub not set up properly. Tub not connected to the motor housing properly Filter not connected inside of cabinet Valve not switched to “Oil to Fryer” If there’s more than one fryer, return valve not open. Place components in tub per the following: 1. Sump screen on the very bottom 2. Filter paper over sump screen (Lie it flat on the bottom, creasing the sides). 3. Hold down ring (ensure paper is not folded, lock hold down ring into place ensuring a tight seal). 4. Sprinkle acidox powder evenly over filter paper (1bag per 40 lbs. of oil). 5. Crumb basket for large debris. 1. Remove tub from the filter cart completely by pulling the release handle located on the bottom of the filter control panel. 2. Place the tub onto the filter cart by first inserting the rear lip under the filter cart frame and then laying down the front of the tub flat onto the cart. 3. Connect the tub to the motor housing by pulling together the handles on the tub and the handles on the motor housing (NOTE: Verify tight connection by pushing back on the tub). 1. Ensure filter assembly is rolled straight onto the rails...

Este manual também é adequado para os modelos :
Air - Safe and Easy Filter (926.18 kb)
Air - Safe and Easy Filter (926.18 kb)
Air - Safe and Easy Filter (926.18 kb)
Air - Safe and Easy Filter (926.18 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias