Log:
Assessments - 5, GPA: 4 ( )

Instruções de Operação APC, Modelo INROW RP ACRP501

Fabricante : APC
Arquivo Tamanho: 944.86 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Note: Reduce airflow and cooling capacity specifications by 7% for cooling units run at low input voltage (380 V). Note: Any CW flow rate of 0.19 l/s - 0.32 l/s (3.0 GPM - 5.0 GPM) may cause an increased error in flow rate and power calculation. A fluid flow fault may result. Any flow rate under 0.19 l/s (3.0 GPM) may also display as 0 in the flow rate and power calculation. Note: For sustained operation, a maximimum flow rate of 2.2 l/s (34 GPM) is recommended. This may be exceeded by 25% for peak conditions. * To convert feet of water to PSIG, use the following formula: ft H2O . 2.307 = PSIG. InRow RP Technical Data Manual Chilled Water Performance Specifications 12.8°C (55°F) EWT Temperature dry bulb (DB), wet bulb (WB) °C (°F) CW Delta T °C (°F) Total Net CapacitykW (BTU/hr) Sensible Net CapacitykW (BTU/hr) Sensible Heat Ratio SHR CW Flow Rate l/s (GPM) Total CW Pressure DropkPa (ftH2O)* 26.7°C DB, 17.1°C WB (80°F DB, 62.8°F WB) 5.5 (10) 24.7 (85,000) 24.7 (85,000) 1.00 1.2 (18.3) 33 (11.3) 6.6 (12) 22.3 (76,000) 22.3 (76,000) 1.00 0.9 (13.9) 20 (6.7) 7.7 (14) 20.0 (68,000) 20.0 (68,000) 1.00 0.7 (10.8) 12 (4.2) 8.8 (16) 17.8 (61,000) 17.8 (61,000) 1.00 0.5 (8.6) 8 (2.8) 10 (18) 15.8 (54,000) 15.8 (54,000) 1.00 0.4 (6.9) 5 (1.8) 11.1 (20) 13.9 (48,000) 13.9 (48,000) 1.00 0.4 (5.6) 4 (1.2) 29.4°C DB, 18.1°C WB (85°F DB, 64.5°F WB) 5.5 (10) 31.3 (107,000) 31.3 (107,000) 1.00 1.4 (22.6) 50 (16.9) 6.6 (12) 28.5 (97,000) 28.5 (97,000) 1.00 1.1 (17.3) 30 (10.2) 7.7 (14) 25.8 (88,000) 25.8 (88,000) 1.00 0.9 (13.6) 19 (6.5) 8.8 (16) 23.3 (80,000) 23.3 (80,000) 1.00 0.7 (10.8) 8 (4.2) 10 (18) 21.0 (72,000) 21.0 (72,000) 1.00 0.6 (8.8) 8 (2.8) 11.1 (20) 18.7 (64,000) 18.7 (64,000) 1.00 0.5 (7.2) 6 (1.8) 32.2°C DB, 18.9°C WB (90°F DB, 66.1°F WB) 5.5 (10) 39.1 (133,000) 39.1 (133,000) 1.00 1.7 (27.7) 75 (24.9) 6.6 (12) 35.9 (123,000) 35.9 (123,000) 1.00 1.3 (21.3) 45 (15.02) 7.7 (14) 32.8 (112,000) 32.8 (112,000) 1.00 1.1 (16.9) 29 (9.7) 8.8 (16) 30.0 (102,000) 30.0 (102,000) 1.00 0.9 (13.6) 19 (6.5) 10 (18) 27.2 (93,000) 27.2 (93,000) 1.00 0.7 (11.1) 13 (4.4) 35.0°C DB, 19.8°C WB (95°F DB, 67.7°F WB) 6.6 (12) 44.2 (151,000) 44.2 (151,000) 1.00 1.6 (25.9) 66 (21.9) 7.7 (14) 40.8 (139,000) 40.8 (139,000) 1.00 1.3 (20.6) 42 (14.1) 8.8 (16) 37.5 (128,000) 37.5 (128,000) 1.00 1.1 (16.7) 28 (9.5) 37.8°C DB, 20.7°C WB (100°F DB, 69.2°F WB) 7.7 (14) 49.8 (170,000) 49.8 (170,000) 1.00 1.6 (24.8) 60 (20.1) 40.6°C DB, 21.6°C WB (105°F DB, 70.8°F WB) 7.7 (14) 59.7 (204,000) 59.7 (204,000) 1.00 1.9 (29.5) 84 (28.2) Note: All values are accurate to +/- 5% and based on full speed with standard filters. Note: Reduce airflow and cooling capacity specifications by 7% for cooling units run at low input voltage (380 V). Note: Any CW flow rate of 0.19 l/s - 0.32 l/s (3.0 GPM - 5.0 GPM) may cause an increased error in flow rate and power calculation. A fluid flow fault may result. Any flow rate under 0.19 l/s (3.0 GPM) may also display as 0 in the flow rate and power calculation. Note: For sustained operation, a maximimum flow rate of 2.2 l/s (34 GPM) is recommended. This may be exceeded by 25% for peak conditions. * To convert feet of water to PSIG, use the following formula: ft H2O . 2.307 = PSIG. InRow RP Technical Data Manual Chilled Water Performance Specifications 15.5°C (60°F) EWT Temperature dry bulb(DB), wet bulb (WB) °C (°F) CW Delta T °C (°F) Total Net CapacitykW (BTU/hr) Sensible Net CapacitykW (BTU/hr) Sensible Heat Ratio SHR CW Flow Rate l/s (GPM) Total CW Pressure DropkPa (ft H2O)* 26.7°C DB, 17.1°C WB (80°F DB, 62.8°F WB) 5.5 (10) 17.5 (60,000) 17.5 (60,000) 1.00 0.9 (13.5) 19 (6.2) 6.6 (12) 15.2 (52,000) 15.2 (52,000) 1.00 0.6 (10.0) 11 (3.7) 7.7 (14) 13.1 (45,000) 13.1 (45,000) 1.00 0.5 (7.6) 6 (2.1) 8.8 (16) 11.1 (38,000) 11.1 (38,000) 1.00 0.4 (5.8) 4 (1.4) 10 (18) 9.3 (32,000) 9.3 (32,000) 1.00 0.3 (4.5) 3 (0.9) 11.1 (20) 7.7 (26,000) 7.7 (26,000) 1.00 0.2 (3.5) 2 (0.5) 29.4°C DB, 18.1°C WB (85°F DB, 64.5°F WB) 5.5 (10) 23.8 (81,000) 23.8 (81,000) 1.00 1.1 (17.7) 31 (10.4) 6.6 (12) 21.1 (72,000) 21.1 (72,000) 1.00 0.8 (13.2) 18 (6.01) 7.7 (14) 18.5 (63,000) 18.5 (63,000) 1.00 0.6 (10.1) 11 (3.7) 8.8 (16) 16.1 (55,000) 16.1 (55,000) 1.00 0.5 (7.9) 7 (2.3) 32.2°C DB, 18.9°C WB (90°F DB, 66.1°F WB) 5.5 (10) 31.5 (108,000) 31.5 (108,000) 1.00 1.4 (22.8) 51 (17.1) 6.6 (12) 28.3 (97,000) 28.3 (97,000) 1.00 1.1 (17.2) 30 (9.9) 35.0°C DB, 19.8°C WB (95°F DB, 67.7°F WB) 5.5 (10) 40.6 (139,000) 40.6 (139,000) 1.00 1.8 (28.7) 80 (26.8) Note: All values are accurate to +/- 5% and based on full speed with standard filters. Note: Reduce airflow and cooling capacity specifications by 7% for cooling units run at low input voltage (380 V). Note: Any CW flow rate of 0.19 l/s - 0.32 l/s (3.0 GPM - 5.0 GPM) may cause an increased error in flow rate and power calculation. A fluid flow fault may result. Any flow rate under 0.19 l/s (3.0 GPM) may also display as 0 in the flow rate and power calculation. Note: For sustained operation, a m...

Este manual também é adequado para os modelos :
Dispensadores - INROW RP ACRP100 (944.86 kb)
Dispensadores - INROW RP ACRP502 (944.86 kb)
Dispensadores - INROW RP ACRP500 (944.86 kb)
Dispensadores - INROW RP ACRP102 (944.86 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias