Facilidade de uso


Fig. 57 42 Fixing the Oven Introduce the oven into the furniture opening and fix it with screws (not supplied) as figure 57. 43 OVEN DOOR LOWER TRIM AIR FLOW IMPORTANT: – To avoid damage to the lower trim please note the following instructions. – The lower trim is designed to allow for good air circulation and the correct opening of the oven door. – To ensure the trim is not damaged due to the appliance being placed on the floor, the appliance should be suitably supported as in below illustrations. – After installation the appliance door should be slowly opened to ensure no damage has occurred. – No responsibility for lower trim damage will be accepted if these instructions have not been followed. Fig. 58 Air Flow Oven Door Lower Trim 43 OVEN DOOR LOWER TRIM AIR FLOW IMPORTANT: – To avoid damage to the lower trim please note the following instructions. – The lower trim is designed to allow for good air circulation and the correct opening of the oven door. – To ensure the trim is not damaged due to the appliance being placed on the floor, the appliance should be suitably supported as in below illustrations. – After installation the appliance door should be slowly opened to ensure no damage has occurred. – No responsibility for lower trim damage will be accepted if these instructions have not been followed. Fig. 58 Air Flow Oven Door Lower Trim 44 44 Electrical Installation For your safety please read the following information: WARNING! Before effecting any intervention on the electrical parts the appliance must be disconnected from the network. IMPORTANT: The oven must be installed in accordance with the manufacturer’s instructions. Incorrect installation, for which the manufacturer accepts no responsibility, may cause damage to persons, animals and things. General – The connection to the electrical network must be carried out by qualified personnel and must be according to existing norms. – The appliance must be connected to the electrical network verifying above all that the voltage corresponds to the value indicated on the specifications plate and that the cables section of the electrical plant can bear the load which is also indicated on the plate. – If the appliance is supplied without a power supply plug and if you are not connecting directly to the mains, a standardized plug suitable for the load must be fitted. – The colours of the wires in the appliance power cable may not correspond with the colours marked on the terminals of your electrical plug. The plug should always be wired as follows: • connect the green/yellow wire to the terminal marked with the letter E or the earth symbol or coloured green/yellow; • connect the blue wire to the terminal marked with the letter N or coloured black; • connect the brown wire to the terminal marked with the letter L or coloured red. – The bi-polar plug must be connected to an outlet connected to the grounding unit in conformity to security norms. – If the oven is to be connected directly to the mains, it must be placed with an omnipolar switch with minimum opening between the contacts of 3 mm between the appliance and the mains. – The power supply cable must not touch the hot parts and must be positioned so that it does not exceed 75°C at any point. – Once the oven has been installed, the switch or socket must always be The connection of accessible. the appliance to the – If the power supply cable is damaged it must be substituted by a suitable grounding unit is cable available in the after sales service. mandatory. The manufacturer Note: For connection to the mains, do not use adapters, reducers or declines every branching devices as they can cause overheating and burning. responsability for any inconvenience If the installation requires alterations to the domestic electrical system call resulting from the an expert. inobservance of this He should also check that the socket cable section is suitable for the power condition. absorbed by the appliance. Open the cable gland by unscrewing screw “F” (fig. 60), unscrew the terminal screws and remove the cable. The new supply cable, of suitable type and section, is connected to the terminal board following the diagram of fig. 61. A F Feeder Cable Section Type H05RR-F 230 V~ 3 x 1.5 mm2 230 V E NL E Earth N Neutral L Live Fig. 59 Fig. 60 Fig. 61 Open the cable gland by unscrewing screw “F” (fig. 60), unscrew the terminal screws and remove the cable. The new supply cable, of suitable type and section, is connected to the terminal board following the diagram of fig. 61. A F Feeder Cable Section Type H05RR-F 230 V~ 3 x 1.5 mm2 230 V E NL E Earth N Neutral L Live Fig. 59 Fig. 60 Fig. 61 45 Connection of the Power Supply Cable Unhook the terminal board cover by inserting a screwdriver into the two hooks “A” (fig. 59). 46 46 Appliance Servicing CDA provide a quality and effective after-sales service to cover all your servicing needs. Please attach your receipt to this page for safekeeping. Please help us to help you by hav...

Este manual também é adequado para os modelos :
Fornos Elétricos - 6Q5 (2.87 mb)
Fornos Elétricos - SC510 (2.87 mb)
Fornos Elétricos - SC610 (2.87 mb)
Fornos Elétricos - SV100 (2.87 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias