Log:
Downloads : 0   Arquivo Tamanho: 1 mb   Fabricante : Bionaire  
Categoria : Eléctrico
@name

Wall Mount Installation: This product weighs 25 lbs. Do not install alone. Mounting Template with instructions is attached below to make mounting your Fireplace Heater easy. • Wall Mount Hardware Kit includes: 4 - 1.5” Phillips head self tapping screws 4 - toggle bolts 2 - mounting brackets IMPORTANT: Before drilling into any wall ensure no electrical cables are present in the area. Max. height of 47” (1.2 m). Make sure you allow at least 3 feet (1m) of space on the sides of unit. 1. Remove stan

Downloads : 2   Arquivo Tamanho: 259 kb   Fabricante : Bionaire  
Categoria : Eléctrico
@name@name

2. 3. 4. 5. 6. 7. 8. 9. 10. 11. e gasoline, paint, or flammable liquids are used or stored. 12.Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by the manufacturer may cause hazards. 13.DO NOT use outdoors. AUTO SAFETY SHUT-OFF WITH INSTANT TIP OVER PROTECTION This heater is equipped with a patented, technologically- adva

Downloads : 8   Arquivo Tamanho: 259 kb   Fabricante : Bionaire  
Categoria : Eléctrico
@name@name

Carefully remove your heater from the box. please save the carton for off-season storage. 2. Make sure the unit is in the OFF position before plugging the heater into the outlet. 3. Place heater on firm level surface. 4. Avoid overloading your circuit by not using other high wattage appliances in the same outlet. At 1500 watts, this unit draws 12.5 Amps. NOTE:The power light will remain lit while heater is plugged in. OPERATING INSTRUCTIONS Your heater is equipped with a technologically advanced

Downloads : 1   Arquivo Tamanho: 7 mb   Fabricante : Bionaire  
Categoria : Eléctrico
@name

It cuts off the power as soon as the heater’s internal temperature becomes too high. This patented, technologically advanced system requires the user to reset the heater in case of a potential overheat situation. It will only resume operation when the user resets it. To Reset the Heater: 1. Unplug the heater and wait 10 minutes for the unit to cool down. 2. After the 10 minutes, plug the unit in and operate normally. PRE-OPERATING INSTRUCTIONS Carefully unpack your heater from the box (it is rec

Downloads : 6   Arquivo Tamanho: 7 mb   Fabricante : Bionaire  
Categoria : Eléctrico
@name

11. DO NOT use outdoors. 12. To prevent a possible fire, DO NOT block air intakes or exhaust in any manner. DO NOT use on soft surfaces, like a bed, where openings may become blocked. 13. To disconnect heater, set controls to OFF, then remove plug from outlet. 14. Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire. However, if you have to use an extension cord, the cord shall be No. 14 AWG minimum size and rated not less than 1875 watts. 15. Alway

Downloads : 5   Arquivo Tamanho: 219 kb   Fabricante : Bionaire  
Categoria : Eléctrico
@name

The "Set" temperature is displayed next to the "Room" temp. The unit will cycle on and off to maintain the "Set" temperature. The default room temp = 72.F/22.C. In this mode the unit will run to maintain the "Set" temperature. 2. Press Mode button on remote again. The remote screen displays "Auto" and "high". The "Set" temperature is displayed next to the "Room" temp. The "Auto" light on unit stays illuminated. The unit will cycle on and off to maintain the "Set" temperature at high wattage (150

Downloads : 2   Arquivo Tamanho: 304 kb   Fabricante : Bionaire  
Categoria : Eléctrico
@name

The heater will run continuously on LO. 3. Press the Mode Button for a third time for Auto Mode HI Power (AH) or press again for Auto Mode LO Power (AL). In either of these modes you may then press the up, and down buttons to reach your desired temperature. 4. Once you have reached your desired temperature, the display will return to current room temperature and gradually increase until the room has reached the preset temperature. 5. If the unit will not start in the digital thermostat mode, ple

Downloads : 3   Arquivo Tamanho: 2 mb   Fabricante : Bionaire  
Categoria : Eléctrico
@name@name

2. To stop oscillation, press the oscillation button again. 3. Please do not manually turn the heater on the base; it is designed to turn only by motorized oscillation. REMOTE CONTROL INSTRUCTIONS 1. Before operation, insert 2 “AAA” batteries into the back of the remote control. • Do not mix old and new batteries. • Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries. The remote control for this unit has the capability of operating all control panel functions.

Downloads : 4   Arquivo Tamanho: 598 kb   Fabricante : Bionaire  
Categoria : Eléctrico
@name@name

Some provinces, states or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from province to province, state to state or jurisdiction to jurisdiction. How to Obtain Warranty Service In the U.S.A. (Stamp comment Approved bellvei 28.05.2008 6:17:59 bla

Downloads : 2   Arquivo Tamanho: 598 kb   Fabricante : Bionaire  
Categoria : Eléctrico
@name@name

Retain for future reference. Instruction Leaflet .INFO-LINE If after having read this leaflet, you have any questions or comments on your heater, call 1-800-253-2764 in North America. 127671/9100020009457 1. Store heater in a cool, dry location. 2. The manufacturer recommends that you store the unit in its original carton. *TIP: Over time, dust may accumulate on the front grills. This can be removed by wiping the unit with a damp cloth. Always unplug unit and allow to cool prior to cleaning. TRO